Tachycardia after pacemaker implantation in a patient with complete atrioventricular block. 2007

Gabor Z Duray, and Carsten W Israel, and Florian T Wegener, and Stefan H Hohnloser
Division of Clinical Electrophysiology, Department of Cardiology, J.W. Goethe University, Theodor Stern Kai 7, 60590 Frankfurt, Germany.

The atrioventricular (AV) node allows ante- and retrograde conduction between atria and ventricles. It is commonly assumed that these AV nodal conduction properties go hand in hand. However, ante- and retrograde AV conduction can be completely independent from each other in individual patients. We report about a patient with permanent AV block III degrees requiring implantation of a pacemaker. As soon as a dual-chamber device was connected to the implanted leads, a tachycardia started at the maximum tracking rate, which was subsequently reprogrammed from 120 to 170 bpm. Non-invasive electrophysiologic testing showed that this patient demonstrated 1:1 ventriculoatrial (VA) conduction up to 170 bpm leading to endless loop tachycardia (ELT) while the antegrade AV block III degrees persisted. This case impressively illustrates that one has to take into account that patients with antegrade AV block III degrees may still have a high VA conduction capacity leading to ELT. Dual-chamber devices therefore have to be programmed accordingly, activating dedicated reactions after ventricular premature beats and automatic ELT detection and termination algorithms.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D010138 Pacemaker, Artificial A device designed to stimulate, by electric impulses, contraction of the heart muscles. It may be temporary (external) or permanent (internal or internal-external). Cardiac Pacemaker, Artificial,Artificial Cardiac Pacemaker,Artificial Cardiac Pacemakers,Artificial Pacemaker,Artificial Pacemakers,Cardiac Pacemakers, Artificial,Pacemaker, Artificial Cardiac,Pacemakers, Artificial,Pacemakers, Artificial Cardiac
D002304 Cardiac Pacing, Artificial Regulation of the rate of contraction of the heart muscles by an artificial pacemaker. Pacing, Cardiac, Artificial,Artificial Cardiac Pacing,Artificial Cardiac Pacings,Cardiac Pacings, Artificial,Pacing, Artificial Cardiac,Pacings, Artificial Cardiac
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D004566 Electrodes Electric conductors through which electric currents enter or leave a medium, whether it be an electrolytic solution, solid, molten mass, gas, or vacuum. Anode,Anode Materials,Cathode,Cathode Materials,Anode Material,Anodes,Cathode Material,Cathodes,Electrode,Material, Anode,Material, Cathode
D004594 Electrophysiology The study of the generation and behavior of electrical charges in living organisms particularly the nervous system and the effects of electricity on living organisms.
D006327 Heart Block Impaired conduction of cardiac impulse that can occur anywhere along the conduction pathway, such as between the SINOATRIAL NODE and the right atrium (SA block) or between atria and ventricles (AV block). Heart blocks can be classified by the duration, frequency, or completeness of conduction block. Reversibility depends on the degree of structural or functional defects. Auriculo-Ventricular Dissociation,A-V Dissociation,Atrioventricular Dissociation,A V Dissociation,A-V Dissociations,Atrioventricular Dissociations,Auriculo Ventricular Dissociation,Auriculo-Ventricular Dissociations,Block, Heart,Blocks, Heart,Dissociation, A-V,Dissociation, Atrioventricular,Dissociation, Auriculo-Ventricular,Dissociations, A-V,Dissociations, Atrioventricular,Dissociations, Auriculo-Ventricular,Heart Blocks
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000465 Algorithms A procedure consisting of a sequence of algebraic formulas and/or logical steps to calculate or determine a given task. Algorithm

Related Publications

Gabor Z Duray, and Carsten W Israel, and Florian T Wegener, and Stefan H Hohnloser
November 1986, American heart journal,
Gabor Z Duray, and Carsten W Israel, and Florian T Wegener, and Stefan H Hohnloser
January 2021, Case reports in cardiology,
Gabor Z Duray, and Carsten W Israel, and Florian T Wegener, and Stefan H Hohnloser
July 2013, Pacing and clinical electrophysiology : PACE,
Gabor Z Duray, and Carsten W Israel, and Florian T Wegener, and Stefan H Hohnloser
February 2008, European journal of pediatrics,
Gabor Z Duray, and Carsten W Israel, and Florian T Wegener, and Stefan H Hohnloser
May 1993, Equine veterinary journal,
Gabor Z Duray, and Carsten W Israel, and Florian T Wegener, and Stefan H Hohnloser
November 1988, Nederlands tijdschrift voor geneeskunde,
Gabor Z Duray, and Carsten W Israel, and Florian T Wegener, and Stefan H Hohnloser
March 2001, The American journal of cardiology,
Gabor Z Duray, and Carsten W Israel, and Florian T Wegener, and Stefan H Hohnloser
June 1967, Minerva medica,
Gabor Z Duray, and Carsten W Israel, and Florian T Wegener, and Stefan H Hohnloser
January 2002, Archives of gerontology and geriatrics. Supplement,
Gabor Z Duray, and Carsten W Israel, and Florian T Wegener, and Stefan H Hohnloser
May 2010, Polski merkuriusz lekarski : organ Polskiego Towarzystwa Lekarskiego,
Copied contents to your clipboard!