Out-of-field dosimetry measurements for a helical tomotherapy system. 2006

Chester Ramsey, and Rebecca Seibert, and Stephen L Mahan, and Dharmin Desai, and Daniel Chase
Thompson Cancer Survival Center, Department of Radiation Oncology, Knoxville, Tennessee 37916, USA. cramsey@utk.edu

Helical tomotherapy is a rotational delivery technique that uses intensity-modulated fan beams to deliver highly conformal intensity-modulated radiation therapy (IMRT). The beam-on time needed to deliver a given prescribed dose can be up to 15 times longer than that needed using conventional treatment delivery. As such, there is concern that this delivery technique has the potential to increase the whole body dose due to increased leakage. The purpose of this work is to directly measure out-of-field doses for a clinical tomotherapy system. Peripheral doses were measured in-phantom using static fields and rotational intensity-modulated delivery. In-air scatter and leakage doses were also measured at multiple locations around the treatment room. At 20 cm, the tomotherapy peripheral dose dropped to 0.4% of the prescribed dose. Leakage accounted for 94% of the in-air dose at distances greater than 60 cm from the machine's isocenter. The largest measured dose equivalent rate was 1 x 10(-4) Sv/s in the plane of gantry rotation due to head leakage and primary beam transmission through the system's beam stopper. The dose equivalent rate dropped to 1 x 10(-6) Sv/s at the end of the treatment couch. Even though helical tomotherapy treatment delivery requires beam-on times that are 5 to 15 times longer than those used by conventional accelerators, the delivery system was designed to maximize shielding for radiation leakage. As such, the peripheral doses are equal to or less than the published peripheral doses for IMRT delivery on other linear accelerators. In addition, the shielding requirements are also similar to conventional linear accelerators.

UI MeSH Term Description Entries
D011829 Radiation Dosage The amount of radiation energy that is deposited in a unit mass of material, such as tissues of plants or animal. In RADIOTHERAPY, radiation dosage is expressed in gray units (Gy). In RADIOLOGIC HEALTH, the dosage is expressed by the product of absorbed dose (Gy) and quality factor (a function of linear energy transfer), and is called radiation dose equivalent in sievert units (Sv). Sievert Units,Dosage, Radiation,Gray Units,Gy Radiation,Sv Radiation Dose Equivalent,Dosages, Radiation,Radiation Dosages,Units, Gray,Units, Sievert
D011874 Radiometry The measurement of radiation by photography, as in x-ray film and film badge, by Geiger-Mueller tube, and by SCINTILLATION COUNTING. Geiger-Mueller Counters,Nuclear Track Detection,Radiation Dosimetry,Dosimetry, Radiation,Geiger Counter,Geiger-Mueller Counter Tube,Geiger-Mueller Probe,Geiger-Mueller Tube,Radiation Counter,Counter Tube, Geiger-Mueller,Counter Tubes, Geiger-Mueller,Counter, Geiger,Counter, Radiation,Counters, Geiger,Counters, Geiger-Mueller,Counters, Radiation,Detection, Nuclear Track,Dosimetries, Radiation,Geiger Counters,Geiger Mueller Counter Tube,Geiger Mueller Counters,Geiger Mueller Probe,Geiger Mueller Tube,Geiger-Mueller Counter Tubes,Geiger-Mueller Probes,Geiger-Mueller Tubes,Probe, Geiger-Mueller,Probes, Geiger-Mueller,Radiation Counters,Radiation Dosimetries,Tube, Geiger-Mueller,Tube, Geiger-Mueller Counter,Tubes, Geiger-Mueller,Tubes, Geiger-Mueller Counter
D011880 Radiotherapy Planning, Computer-Assisted Computer-assisted mathematical calculations of beam angles, intensities of radiation, and duration of irradiation in radiotherapy. Computer-Assisted Radiotherapy Planning,Dosimetry Calculations, Computer-Assisted,Planning, Computer-Assisted Radiotherapy,Calculation, Computer-Assisted Dosimetry,Calculations, Computer-Assisted Dosimetry,Computer Assisted Radiotherapy Planning,Computer-Assisted Dosimetry Calculation,Computer-Assisted Dosimetry Calculations,Dosimetry Calculation, Computer-Assisted,Dosimetry Calculations, Computer Assisted,Planning, Computer Assisted Radiotherapy,Radiotherapy Planning, Computer Assisted
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D050397 Radiotherapy, Intensity-Modulated CONFORMAL RADIOTHERAPY that combines several intensity-modulated beams to provide improved dose homogeneity and highly conformal dose distributions. Helical Tomotherapy,Intensity-Modulated Arc Therapy,Volumetric-Modulated Arc Therapy,Arc Therapies, Intensity-Modulated,Arc Therapies, Volumetric-Modulated,Arc Therapy, Intensity-Modulated,Arc Therapy, Volumetric-Modulated,Helical Tomotherapies,Intensity Modulated Arc Therapy,Intensity-Modulated Arc Therapies,Intensity-Modulated Radiotherapies,Intensity-Modulated Radiotherapy,Radiotherapies, Intensity-Modulated,Radiotherapy, Intensity Modulated,Therapies, Intensity-Modulated Arc,Therapies, Volumetric-Modulated Arc,Therapy, Intensity-Modulated Arc,Therapy, Volumetric-Modulated Arc,Tomotherapies, Helical,Tomotherapy, Helical,Volumetric Modulated Arc Therapy,Volumetric-Modulated Arc Therapies
D019047 Phantoms, Imaging Devices or objects in various imaging techniques used to visualize or enhance visualization by simulating conditions encountered in the procedure. Phantoms are used very often in procedures employing or measuring x-irradiation or radioactive material to evaluate performance. Phantoms often have properties similar to human tissue. Water demonstrates absorbing properties similar to normal tissue, hence water-filled phantoms are used to map radiation levels. Phantoms are used also as teaching aids to simulate real conditions with x-ray or ultrasonic machines. (From Iturralde, Dictionary and Handbook of Nuclear Medicine and Clinical Imaging, 1990) Phantoms, Radiographic,Phantoms, Radiologic,Radiographic Phantoms,Radiologic Phantoms,Phantom, Radiographic,Phantom, Radiologic,Radiographic Phantom,Radiologic Phantom,Imaging Phantom,Imaging Phantoms,Phantom, Imaging

Related Publications

Chester Ramsey, and Rebecca Seibert, and Stephen L Mahan, and Dharmin Desai, and Daniel Chase
December 2003, Medical physics,
Chester Ramsey, and Rebecca Seibert, and Stephen L Mahan, and Dharmin Desai, and Daniel Chase
November 2011, Medical physics,
Chester Ramsey, and Rebecca Seibert, and Stephen L Mahan, and Dharmin Desai, and Daniel Chase
June 2010, Medical physics,
Chester Ramsey, and Rebecca Seibert, and Stephen L Mahan, and Dharmin Desai, and Daniel Chase
December 2005, Australasian physical & engineering sciences in medicine,
Chester Ramsey, and Rebecca Seibert, and Stephen L Mahan, and Dharmin Desai, and Daniel Chase
March 2011, Medical physics,
Chester Ramsey, and Rebecca Seibert, and Stephen L Mahan, and Dharmin Desai, and Daniel Chase
November 2005, Medical physics,
Chester Ramsey, and Rebecca Seibert, and Stephen L Mahan, and Dharmin Desai, and Daniel Chase
January 2015, Journal of applied clinical medical physics,
Chester Ramsey, and Rebecca Seibert, and Stephen L Mahan, and Dharmin Desai, and Daniel Chase
May 1998, Physics in medicine and biology,
Chester Ramsey, and Rebecca Seibert, and Stephen L Mahan, and Dharmin Desai, and Daniel Chase
November 2011, Journal of applied clinical medical physics,
Chester Ramsey, and Rebecca Seibert, and Stephen L Mahan, and Dharmin Desai, and Daniel Chase
January 2001, Medical dosimetry : official journal of the American Association of Medical Dosimetrists,
Copied contents to your clipboard!