Integral test phantom for dosimetric quality assurance of image guided and intensity modulated stereotactic radiotherapy. 2007

Daniel Létourneau, and Harald Keller, and Michael B Sharpe, and David A Jaffray
Radiation Medicine Program, Princess Margaret Hospital, Toronto, Ontario, Canada M5G 2M9. Daniel.Letourneau@rmp.uhn.on.ca

The objective of this work is to develop a dosimetric phantom quality assurance (QA) of linear accelerators capable of cone-beam CT (CBCT) image guided and intensity-modulated radiotherapy (IG-IMRT). This phantom is to be used in an integral test to quantify in real-time both the performance of the image guidance and the dose delivery systems in terms of dose localization. The prototype IG-IMRT QA phantom consisted of a cylindrical imaging phantom (CatPhan) combined with an array of 11 radiation diodes mounted on a 10 cm diameter disk, oriented perpendicular to the phantom axis. Basic diode response characterization was performed for 6 and 18 MV photons. The diode response was compared to planning system calculations in the open and penumbrae regions of simple and complex beam arrangements. The clinical use of the QA phantom was illustrated in an integral test of an IG-IMRT treatment designed for a clinical spinal radiosurgery case. The sensitivity of the phantom to multileaf collimator (MLC) calibration and setup errors in the clinical setting was assessed by introducing errors in the IMRT plan or by displacing the phantom. The diodes offered good response linearity and long-term reproducibility for both 6 and 18 MV. Axial dosimetry of coplanar beams (in a plane containing the beam axes) was made possible with the nearly isoplanatic response of the diodes over 360 degrees of gantry (usually within +/-1%). For single beam geometry, errors in phantom placement as small as 0.5 mm could be accurately detected (in gradient > or = 1% /mm). In clinical setting, MLC systematic errors of 1 mm on a single MLC bank introduced in the IMRT plan were easily detectable with the QA phantom. The QA phantom demonstrated also sufficient sensitivity for the detection of setup errors as small as 1 mm for the IMRT delivery. These results demonstrated that the prototype can accurately and efficiently verify the entire IG-IMRT process. This tool, in conjunction with image guidance capabilities has the potential to streamline this QA process and improve the level of performance of image guided and intensity modulated radiotherapy.

UI MeSH Term Description Entries
D010315 Particle Accelerators Devices which accelerate electrically charged atomic or subatomic particles, such as electrons, protons or ions, to high velocities so they have high kinetic energy. Betatrons,Linear Accelerators,Accelerator, Linear,Accelerator, Particle,Accelerators, Linear,Accelerators, Particle,Betatron,Linear Accelerator,Particle Accelerator
D011786 Quality Control A system for verifying and maintaining a desired level of quality in a product or process by careful planning, use of proper equipment, continued inspection, and corrective action as required. (Random House Unabridged Dictionary, 2d ed) Control, Quality,Controls, Quality,Quality Controls
D011882 Radiotherapy, High-Energy Radiotherapy using high-energy (megavolt or higher) ionizing radiation. Types of radiation include gamma rays, produced by a radioisotope within a teletherapy unit; x-rays, electrons, protons, alpha particles (helium ions) and heavy charged ions, produced by particle acceleration; and neutrons and pi-mesons (pions), produced as secondary particles following bombardment of a target with a primary particle. Megavolt Radiotherapy,High-Energy Radiotherapy,Radiotherapy, Megavolt,High Energy Radiotherapy,Radiotherapy, High Energy
D019047 Phantoms, Imaging Devices or objects in various imaging techniques used to visualize or enhance visualization by simulating conditions encountered in the procedure. Phantoms are used very often in procedures employing or measuring x-irradiation or radioactive material to evaluate performance. Phantoms often have properties similar to human tissue. Water demonstrates absorbing properties similar to normal tissue, hence water-filled phantoms are used to map radiation levels. Phantoms are used also as teaching aids to simulate real conditions with x-ray or ultrasonic machines. (From Iturralde, Dictionary and Handbook of Nuclear Medicine and Clinical Imaging, 1990) Phantoms, Radiographic,Phantoms, Radiologic,Radiographic Phantoms,Radiologic Phantoms,Phantom, Radiographic,Phantom, Radiologic,Radiographic Phantom,Radiologic Phantom,Imaging Phantom,Imaging Phantoms,Phantom, Imaging

Related Publications

Daniel Létourneau, and Harald Keller, and Michael B Sharpe, and David A Jaffray
July 2005, Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al],
Daniel Létourneau, and Harald Keller, and Michael B Sharpe, and David A Jaffray
January 2012, Medical dosimetry : official journal of the American Association of Medical Dosimetrists,
Daniel Létourneau, and Harald Keller, and Michael B Sharpe, and David A Jaffray
July 2002, Seminars in radiation oncology,
Daniel Létourneau, and Harald Keller, and Michael B Sharpe, and David A Jaffray
January 1998, Radiation oncology investigations,
Daniel Létourneau, and Harald Keller, and Michael B Sharpe, and David A Jaffray
May 2009, Medical physics,
Daniel Létourneau, and Harald Keller, and Michael B Sharpe, and David A Jaffray
January 2003, Medical dosimetry : official journal of the American Association of Medical Dosimetrists,
Daniel Létourneau, and Harald Keller, and Michael B Sharpe, and David A Jaffray
March 2013, Journal of medical imaging and radiation sciences,
Daniel Létourneau, and Harald Keller, and Michael B Sharpe, and David A Jaffray
February 2021, Acta oncologica (Stockholm, Sweden),
Daniel Létourneau, and Harald Keller, and Michael B Sharpe, and David A Jaffray
December 2016, Critical reviews in oncology/hematology,
Daniel Létourneau, and Harald Keller, and Michael B Sharpe, and David A Jaffray
February 2012, Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al],
Copied contents to your clipboard!