GafChromic XR-QA film in testing panoramic dental radiography. 2007

Robert Y Chu, and Tin Lam, and Yongguang Liang
Department of Radiological Sciences, University of Oklahoma Health Science Center, Oklahoma City, Oklahoma 73190, USA. robert-chu@ouhsc.edu

The location and field size of the incident X-ray beam in panoramic dental radiography cannot be ascertained visually most of the time. However, these parameters are needed for quality control and dosimetry determination. To alleviate this problem, we tested GafChromic XR-QA film on two panoramic systems. For each system, we used the length of a cross-sectional image of the incident beam and the exposure measurement with a pencil ion chamber to compute the dose-area product. The result was confirmed by direct analysis of a dose distribution on a film. Placement of the ion chamber was determined by the latter images. The GafChromic XR-QA version of radiochromic film has thus been demonstrated to usefully complement a pencil ion chamber in the testing of a panoramic radiography system.

UI MeSH Term Description Entries
D011785 Quality Assurance, Health Care Activities and programs intended to assure or improve the quality of care in either a defined medical setting or a program. The concept includes the assessment or evaluation of the quality of care; identification of problems or shortcomings in the delivery of care; designing activities to overcome these deficiencies; and follow-up monitoring to ensure effectiveness of corrective steps. Quality Assessment, Health Care,Health Care Quality Assessment,Health Care Quality Assurance,Healthcare Quality Assessment,Healthcare Quality Assurance,Quality Assessment, Healthcare,Quality Assurance, Healthcare,Assessment, Healthcare Quality,Assessments, Healthcare Quality,Assurance, Healthcare Quality,Assurances, Healthcare Quality,Healthcare Quality Assessments,Healthcare Quality Assurances,Quality Assessments, Healthcare,Quality Assurances, Healthcare
D011829 Radiation Dosage The amount of radiation energy that is deposited in a unit mass of material, such as tissues of plants or animal. In RADIOTHERAPY, radiation dosage is expressed in gray units (Gy). In RADIOLOGIC HEALTH, the dosage is expressed by the product of absorbed dose (Gy) and quality factor (a function of linear energy transfer), and is called radiation dose equivalent in sievert units (Sv). Sievert Units,Dosage, Radiation,Gray Units,Gy Radiation,Sv Radiation Dose Equivalent,Dosages, Radiation,Radiation Dosages,Units, Gray,Units, Sievert
D011857 Radiographic Image Interpretation, Computer-Assisted Computer systems or networks designed to provide radiographic interpretive information. Computer Assisted Radiographic Image Interpretation,Computer-Assisted Radiographic Image Interpretation,Radiographic Image Interpretation, Computer Assisted
D011862 Radiography, Panoramic Extraoral body-section radiography depicting an entire maxilla, or both maxilla and mandible, on a single film. Orthopantomography,Panoramic Radiography,Pantomography,Orthopantomographies,Panoramic Radiographies,Pantomographies,Radiographies, Panoramic
D005373 Film Dosimetry Use of a device (film badge) for measuring exposure of individuals to radiation. It is usually made of metal, plastic, or paper and loaded with one or more pieces of x-ray film. Film Badge Dosimetry,Film Badge,Badge Dosimetries, Film,Badge Dosimetry, Film,Badge, Film,Badges, Film,Dosimetries, Film,Dosimetries, Film Badge,Dosimetry, Film,Dosimetry, Film Badge,Film Badge Dosimetries,Film Badges,Film Dosimetries
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face

Related Publications

Robert Y Chu, and Tin Lam, and Yongguang Liang
January 2013, Dento maxillo facial radiology,
Robert Y Chu, and Tin Lam, and Yongguang Liang
July 2009, Medical physics,
Robert Y Chu, and Tin Lam, and Yongguang Liang
June 2006, Physics in medicine and biology,
Robert Y Chu, and Tin Lam, and Yongguang Liang
September 1970, Nihon Shika Ishikai zasshi,
Robert Y Chu, and Tin Lam, and Yongguang Liang
January 1966, Anales espanoles de odontoestomatologia,
Robert Y Chu, and Tin Lam, and Yongguang Liang
January 1967, Majallat tibb al-asnan al-Suriyah,
Robert Y Chu, and Tin Lam, and Yongguang Liang
January 1967, The Greater Milwaukee dental bulletin,
Robert Y Chu, and Tin Lam, and Yongguang Liang
April 1983, Australian dental journal,
Robert Y Chu, and Tin Lam, and Yongguang Liang
January 2005, Journal of applied clinical medical physics,
Robert Y Chu, and Tin Lam, and Yongguang Liang
May 1966, Revue francaise d'odonto-stomatologie,
Copied contents to your clipboard!