Statistical variations of ultrasound signals backscattered from flowing blood. 2007

Chih-Chung Huang, and Shyh-Hau Wang
Department of Biomedical Engineering and R & D Center for Membrane Technology, Chung Yuan Christian University, Chung Li, Taiwan. j648816n@ms23.hinet.net

The statistical distributions of ultrasonic signals backscattered from blood have recently been used to characterize hemodynamic properties, such as red blood cell (RBC) aggregation and blood coagulation. However, a thorough understanding of the relationship between blood properties and the statistical behavior of signals backscattered from flowing blood is still lacking. This prompted us to use the statistical parameter to characterize signals backscattered from both whole blood and RBC suspensions at different flow velocities (from 10 to 60 cm/s) and hematocrits (from 20% to 50%) under a steady laminar flow condition. The Nakagami parameter, scaling parameter, backscatter amplitude profile and flow velocity profile across a flow tube were acquired using a 10 MHz focused ultrasonic transducer. The backscattered signal peaked approximately at the centerline of the flow tube due to the effects of RBC aggregation, with the peak value increasing as the flow velocity of whole blood decreased. The Nakagami parameter increased from 0.45 to 0.78 as the flow velocity increased from 10 to 60 cm/s. The probability density function (PDF) of signals backscattered from flowing whole blood conformed with a pre-Rayleigh distribution. The Nakagami parameter was close to 1 for signals backscattered from RBC suspensions at all the flow velocities and hematocrits tested, for which the PDF was Rayleigh distributed. These differences in the statistical distributions of backscattered signals between whole blood and RBC suspensions suggest that variations in the size of dynamic scatterers in the flow affect the shape of the backscattered signal envelope, which should be considered in future statistical models used to characterize blood properties.

UI MeSH Term Description Entries
D001769 Blood The body fluid that circulates in the vascular system (BLOOD VESSELS). Whole blood includes PLASMA and BLOOD CELLS.
D001783 Blood Flow Velocity A value equal to the total volume flow divided by the cross-sectional area of the vascular bed. Blood Flow Velocities,Flow Velocities, Blood,Flow Velocity, Blood,Velocities, Blood Flow,Velocity, Blood Flow
D004903 Erythrocyte Aggregation The formation of clumps of RED BLOOD CELLS under low or non-flow conditions, resulting from the attraction forces between the red blood cells. The cells adhere to each other in rouleaux aggregates. Slight mechanical force, such as occurs in the circulation, is enough to disperse these aggregates. Stronger or weaker than normal aggregation may result from a variety of effects in the ERYTHROCYTE MEMBRANE or in BLOOD PLASMA. The degree of aggregation is affected by ERYTHROCYTE DEFORMABILITY, erythrocyte membrane sialylation, masking of negative surface charge by plasma proteins, etc. BLOOD VISCOSITY and the ERYTHROCYTE SEDIMENTATION RATE are affected by the amount of erythrocyte aggregation and are parameters used to measure the aggregation. Erythrocyte Aggregation, Intravascular,Agglutination, Intravascular,Intravascular Agglutination,Intravascular Erythrocyte Aggregation,Rouleaux Formation, Erythrocyte,Agglutinations, Intravascular,Aggregation, Erythrocyte,Aggregation, Intravascular Erythrocyte,Aggregations, Erythrocyte,Aggregations, Intravascular Erythrocyte,Erythrocyte Aggregations,Erythrocyte Aggregations, Intravascular,Erythrocyte Rouleaux Formation,Erythrocyte Rouleaux Formations,Formation, Erythrocyte Rouleaux,Formations, Erythrocyte Rouleaux,Intravascular Agglutinations,Intravascular Erythrocyte Aggregations,Rouleaux Formations, Erythrocyte
D004912 Erythrocytes Red blood cells. Mature erythrocytes are non-nucleated, biconcave disks containing HEMOGLOBIN whose function is to transport OXYGEN. Blood Cells, Red,Blood Corpuscles, Red,Red Blood Cells,Red Blood Corpuscles,Blood Cell, Red,Blood Corpuscle, Red,Erythrocyte,Red Blood Cell,Red Blood Corpuscle
D006400 Hematocrit The volume of packed RED BLOOD CELLS in a blood specimen. The volume is measured by centrifugation in a tube with graduated markings, or with automated blood cell counters. It is an indicator of erythrocyte status in disease. For example, ANEMIA shows a low value; POLYCYTHEMIA, a high value. Erythrocyte Volume, Packed,Packed Red-Cell Volume,Erythrocyte Volumes, Packed,Hematocrits,Packed Erythrocyte Volume,Packed Erythrocyte Volumes,Packed Red Cell Volume,Packed Red-Cell Volumes,Red-Cell Volume, Packed,Red-Cell Volumes, Packed,Volume, Packed Erythrocyte,Volume, Packed Red-Cell,Volumes, Packed Erythrocyte,Volumes, Packed Red-Cell
D000818 Animals Unicellular or multicellular, heterotrophic organisms, that have sensation and the power of voluntary movement. Under the older five kingdom paradigm, Animalia was one of the kingdoms. Under the modern three domain model, Animalia represents one of the many groups in the domain EUKARYOTA. Animal,Metazoa,Animalia
D015233 Models, Statistical Statistical formulations or analyses which, when applied to data and found to fit the data, are then used to verify the assumptions and parameters used in the analysis. Examples of statistical models are the linear model, binomial model, polynomial model, two-parameter model, etc. Probabilistic Models,Statistical Models,Two-Parameter Models,Model, Statistical,Models, Binomial,Models, Polynomial,Statistical Model,Binomial Model,Binomial Models,Model, Binomial,Model, Polynomial,Model, Probabilistic,Model, Two-Parameter,Models, Probabilistic,Models, Two-Parameter,Polynomial Model,Polynomial Models,Probabilistic Model,Two Parameter Models,Two-Parameter Model
D018056 Hemorheology The deformation and flow behavior of BLOOD and its elements i.e., PLASMA; ERYTHROCYTES; WHITE BLOOD CELLS; and BLOOD PLATELETS. Hemorrheology
D018608 Ultrasonography, Doppler Ultrasonography applying the Doppler effect, with frequency-shifted ultrasound reflections produced by moving targets (usually red blood cells) in the bloodstream along the ultrasound axis in direct proportion to the velocity of movement of the targets, to determine both direction and velocity of blood flow. (Stedman, 25th ed) Doppler Ultrasonography,Doppler Ultrasound,Doppler Ultrasound Imaging,Doppler Ultrasound Imagings,Doppler Ultrasounds,Imaging, Doppler Ultrasound,Imagings, Doppler Ultrasound,Ultrasound Imaging, Doppler,Ultrasound Imagings, Doppler,Ultrasound, Doppler,Ultrasounds, Doppler
D019047 Phantoms, Imaging Devices or objects in various imaging techniques used to visualize or enhance visualization by simulating conditions encountered in the procedure. Phantoms are used very often in procedures employing or measuring x-irradiation or radioactive material to evaluate performance. Phantoms often have properties similar to human tissue. Water demonstrates absorbing properties similar to normal tissue, hence water-filled phantoms are used to map radiation levels. Phantoms are used also as teaching aids to simulate real conditions with x-ray or ultrasonic machines. (From Iturralde, Dictionary and Handbook of Nuclear Medicine and Clinical Imaging, 1990) Phantoms, Radiographic,Phantoms, Radiologic,Radiographic Phantoms,Radiologic Phantoms,Phantom, Radiographic,Phantom, Radiologic,Radiographic Phantom,Radiologic Phantom,Imaging Phantom,Imaging Phantoms,Phantom, Imaging

Related Publications

Chih-Chung Huang, and Shyh-Hau Wang
June 2012, IEEE transactions on ultrasonics, ferroelectrics, and frequency control,
Chih-Chung Huang, and Shyh-Hau Wang
October 2012, Ultrasound in medicine & biology,
Chih-Chung Huang, and Shyh-Hau Wang
November 1995, Ultrasonics,
Chih-Chung Huang, and Shyh-Hau Wang
February 2010, Acta cirurgica brasileira,
Chih-Chung Huang, and Shyh-Hau Wang
January 1986, IEEE transactions on bio-medical engineering,
Chih-Chung Huang, and Shyh-Hau Wang
January 1998, IEEE transactions on ultrasonics, ferroelectrics, and frequency control,
Chih-Chung Huang, and Shyh-Hau Wang
December 1982, Science (New York, N.Y.),
Chih-Chung Huang, and Shyh-Hau Wang
May 1992, IEEE transactions on bio-medical engineering,
Chih-Chung Huang, and Shyh-Hau Wang
March 2004, IEEE transactions on ultrasonics, ferroelectrics, and frequency control,
Chih-Chung Huang, and Shyh-Hau Wang
January 2022, Diagnostics (Basel, Switzerland),
Copied contents to your clipboard!