Implementation of a quality assurance program for computerized treatment planning systems. 2007

Priscilla R T L Camargo, and Laura N Rodrigues, and Laura Furnari, and Rodrigo A Rubo
Centro de Metrologia das Radiações, Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN), Av. Prof Lineu Prestes 2242, CEP 05508-900, São Paulo, Brazil.

In the present investigation, the necessary tests for implementing a quality assurance program for a commercial treatment planning system (TPS), recently installed at Sao Paulo University School of Medicine Clinicas Hospital-Brazil, was established and performed in accordance with the new IAEA publication TRS 430, and with AAPM Task Group 53. The tests recommended by those documents are classified mainly into acceptance, commissioning (dosimetric and nondosimetric), periodic quality assurance, and patient specific quality assurance tests. The recommendations of both IAEA and AAPM documents are being implemented at the hospital for photon beams produced by two linear accelerators. A Farmer ionization chamber was used in a 30 x 30 x 30 cm3 phantom with a dose rate of 320 monitor unit (MU)/min and 50 MU in the case of the dosimetric tests. The acceptance tests verified hardware, network systems integration, data transfer, and software parameters. The results obtained are in good agreement with the specifications of the manufacturer. For the commissioning dosimetric tests, the absolute dose was measured for simple geometries, such as square and rectangular fields, up to more complex geometries such as off-axis hard wedges and for behavior in the build up region. Results were analysed by the use of confidence limit as proposed by Venselaar et al. [Radio Ther. Oncol. 60, 191-201 (2001)]. Criteria of acceptability had been applied also for the comparison between the values of MU calculated manually and MU generated by TPS. The results of the dosimetric tests show that work can be reduced by choosing to perform only those that are more crucial, such as oblique incidence, shaped fields, hard wedges, and buildup region behavior. Staff experience with the implementation of the quality assurance program for a commercial TPS is extremely useful as part of a training program.

UI MeSH Term Description Entries
D010315 Particle Accelerators Devices which accelerate electrically charged atomic or subatomic particles, such as electrons, protons or ions, to high velocities so they have high kinetic energy. Betatrons,Linear Accelerators,Accelerator, Linear,Accelerator, Particle,Accelerators, Linear,Accelerators, Particle,Betatron,Linear Accelerator,Particle Accelerator
D011785 Quality Assurance, Health Care Activities and programs intended to assure or improve the quality of care in either a defined medical setting or a program. The concept includes the assessment or evaluation of the quality of care; identification of problems or shortcomings in the delivery of care; designing activities to overcome these deficiencies; and follow-up monitoring to ensure effectiveness of corrective steps. Quality Assessment, Health Care,Health Care Quality Assessment,Health Care Quality Assurance,Healthcare Quality Assessment,Healthcare Quality Assurance,Quality Assessment, Healthcare,Quality Assurance, Healthcare,Assessment, Healthcare Quality,Assessments, Healthcare Quality,Assurance, Healthcare Quality,Assurances, Healthcare Quality,Healthcare Quality Assessments,Healthcare Quality Assurances,Quality Assessments, Healthcare,Quality Assurances, Healthcare
D011874 Radiometry The measurement of radiation by photography, as in x-ray film and film badge, by Geiger-Mueller tube, and by SCINTILLATION COUNTING. Geiger-Mueller Counters,Nuclear Track Detection,Radiation Dosimetry,Dosimetry, Radiation,Geiger Counter,Geiger-Mueller Counter Tube,Geiger-Mueller Probe,Geiger-Mueller Tube,Radiation Counter,Counter Tube, Geiger-Mueller,Counter Tubes, Geiger-Mueller,Counter, Geiger,Counter, Radiation,Counters, Geiger,Counters, Geiger-Mueller,Counters, Radiation,Detection, Nuclear Track,Dosimetries, Radiation,Geiger Counters,Geiger Mueller Counter Tube,Geiger Mueller Counters,Geiger Mueller Probe,Geiger Mueller Tube,Geiger-Mueller Counter Tubes,Geiger-Mueller Probes,Geiger-Mueller Tubes,Probe, Geiger-Mueller,Probes, Geiger-Mueller,Radiation Counters,Radiation Dosimetries,Tube, Geiger-Mueller,Tube, Geiger-Mueller Counter,Tubes, Geiger-Mueller,Tubes, Geiger-Mueller Counter
D011879 Radiotherapy Dosage The total amount of radiation absorbed by tissues as a result of radiotherapy. Dosage, Radiotherapy,Dosages, Radiotherapy,Radiotherapy Dosages
D011880 Radiotherapy Planning, Computer-Assisted Computer-assisted mathematical calculations of beam angles, intensities of radiation, and duration of irradiation in radiotherapy. Computer-Assisted Radiotherapy Planning,Dosimetry Calculations, Computer-Assisted,Planning, Computer-Assisted Radiotherapy,Calculation, Computer-Assisted Dosimetry,Calculations, Computer-Assisted Dosimetry,Computer Assisted Radiotherapy Planning,Computer-Assisted Dosimetry Calculation,Computer-Assisted Dosimetry Calculations,Dosimetry Calculation, Computer-Assisted,Dosimetry Calculations, Computer Assisted,Planning, Computer Assisted Radiotherapy,Radiotherapy Planning, Computer Assisted
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D012984 Software Sequential operating programs and data which instruct the functioning of a digital computer. Computer Programs,Computer Software,Open Source Software,Software Engineering,Software Tools,Computer Applications Software,Computer Programs and Programming,Computer Software Applications,Application, Computer Software,Applications Software, Computer,Applications Softwares, Computer,Applications, Computer Software,Computer Applications Softwares,Computer Program,Computer Software Application,Engineering, Software,Open Source Softwares,Program, Computer,Programs, Computer,Software Application, Computer,Software Applications, Computer,Software Tool,Software, Computer,Software, Computer Applications,Software, Open Source,Softwares, Computer Applications,Softwares, Open Source,Source Software, Open,Source Softwares, Open,Tool, Software,Tools, Software
D019047 Phantoms, Imaging Devices or objects in various imaging techniques used to visualize or enhance visualization by simulating conditions encountered in the procedure. Phantoms are used very often in procedures employing or measuring x-irradiation or radioactive material to evaluate performance. Phantoms often have properties similar to human tissue. Water demonstrates absorbing properties similar to normal tissue, hence water-filled phantoms are used to map radiation levels. Phantoms are used also as teaching aids to simulate real conditions with x-ray or ultrasonic machines. (From Iturralde, Dictionary and Handbook of Nuclear Medicine and Clinical Imaging, 1990) Phantoms, Radiographic,Phantoms, Radiologic,Radiographic Phantoms,Radiologic Phantoms,Phantom, Radiographic,Phantom, Radiologic,Radiographic Phantom,Radiologic Phantom,Imaging Phantom,Imaging Phantoms,Phantom, Imaging

Related Publications

Priscilla R T L Camargo, and Laura N Rodrigues, and Laura Furnari, and Rodrigo A Rubo
March 1992, Medical dosimetry : official journal of the American Association of Medical Dosimetrists,
Priscilla R T L Camargo, and Laura N Rodrigues, and Laura Furnari, and Rodrigo A Rubo
May 2004, Nihon Hoshasen Gijutsu Gakkai zasshi,
Priscilla R T L Camargo, and Laura N Rodrigues, and Laura Furnari, and Rodrigo A Rubo
August 1987, Journal of nursing quality assurance,
Priscilla R T L Camargo, and Laura N Rodrigues, and Laura Furnari, and Rodrigo A Rubo
November 1983, Topics in hospital pharmacy management,
Priscilla R T L Camargo, and Laura N Rodrigues, and Laura Furnari, and Rodrigo A Rubo
June 1983, Evaluation & the health professions,
Priscilla R T L Camargo, and Laura N Rodrigues, and Laura Furnari, and Rodrigo A Rubo
July 1988, Nursing management,
Priscilla R T L Camargo, and Laura N Rodrigues, and Laura Furnari, and Rodrigo A Rubo
October 2010, Journal of medical physics,
Priscilla R T L Camargo, and Laura N Rodrigues, and Laura Furnari, and Rodrigo A Rubo
January 2005, Journal of applied clinical medical physics,
Priscilla R T L Camargo, and Laura N Rodrigues, and Laura Furnari, and Rodrigo A Rubo
July 1992, Endoscopy,
Priscilla R T L Camargo, and Laura N Rodrigues, and Laura Furnari, and Rodrigo A Rubo
April 1987, Radiology,
Copied contents to your clipboard!