The quantification of EMG normalization error. 1991

G A Mirka
Department of Industrial and Systems Engineering, Ohio State University, Columbus 43210.

Electromyography (EMG) and normalized EMG have been accepted as methods of quantifying the activity level of a muscle. Normalized EMG, in conjunction with the EMG/force relationship and muscle cross-sectional area data, allows researchers to estimate the amount of muscle force exerted across a joint. An accurate description of this muscle force is a critical input to models designed to describe the risk of injury of a task. In order to be able to make statements about the relative intensity of an EMG signal, researchers who use normalization procedures take a given EMG activity level, at a known joint angle, and relate it to some reference activity level obtained at that particular joint angle. However, there have been studies where the EMG activity of an unrestricted dynamic task, such as walking, cycling, performing an occupational task, etc., has been normalized with respect to an EMG value taken during a single maximum voluntary contraction performed at one reference joint angle. This practice will render inaccurate results because at different joint angles there are changes in the portion of the muscle within the viewing area of the electrode, as well as changes in the length/tension relationship of the muscle which would cause changes in the maximum EMG value. The present study was an attempt to quantify the errors associated with normalization relative to a reference EMG value collected at an arbitrary joint position. Four subjects performed a series of controlled trunk extension exertions. As they performed these exertions the EMG activities were collected for eight trunk muscles. The task EMG values that resulted were then: (1) all normalized with respect to the maximum EMG at a single arbitrary trunk angle and (2) each normalized with respect to that specific trunk angle's maximum EMG. The results show that for the primary trunk extensors (erector spinae) large errors (greater than 75%) resulted from normalization using a single reference point and the magnitude of these errors followed consistent patterns within subjects as a function of trunk angle.

UI MeSH Term Description Entries
D008297 Male Males
D008991 Monitoring, Physiologic The continuous measurement of physiological processes, blood pressure, heart rate, renal output, reflexes, respiration, etc., in a patient or experimental animal; includes pharmacologic monitoring, the measurement of administered drugs or their metabolites in the blood, tissues, or urine. Patient Monitoring,Monitoring, Physiological,Physiologic Monitoring,Monitoring, Patient,Physiological Monitoring
D009119 Muscle Contraction A process leading to shortening and/or development of tension in muscle tissue. Muscle contraction occurs by a sliding filament mechanism whereby actin filaments slide inward among the myosin filaments. Inotropism,Muscular Contraction,Contraction, Muscle,Contraction, Muscular,Contractions, Muscle,Contractions, Muscular,Inotropisms,Muscle Contractions,Muscular Contractions
D003627 Data Interpretation, Statistical Application of statistical procedures to analyze specific observed or assumed facts from a particular study. Data Analysis, Statistical,Data Interpretations, Statistical,Interpretation, Statistical Data,Statistical Data Analysis,Statistical Data Interpretation,Analyses, Statistical Data,Analysis, Statistical Data,Data Analyses, Statistical,Interpretations, Statistical Data,Statistical Data Analyses,Statistical Data Interpretations
D004576 Electromyography Recording of the changes in electric potential of muscle by means of surface or needle electrodes. Electromyogram,Surface Electromyography,Electromyograms,Electromyographies,Electromyographies, Surface,Electromyography, Surface,Surface Electromyographies
D005082 Physical Exertion Expenditure of energy during PHYSICAL ACTIVITY. Intensity of exertion may be measured by rate of OXYGEN CONSUMPTION; HEAT produced, or HEART RATE. Perceived exertion, a psychological measure of exertion, is included. Physical Effort,Effort, Physical,Efforts, Physical,Exertion, Physical,Exertions, Physical,Physical Efforts,Physical Exertions
D005260 Female Females
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D001416 Back Pain Acute or chronic pain located in the posterior regions of the THORAX; LUMBOSACRAL REGION; or the adjacent regions. Backache,Back Ache,Back Pain with Radiation,Back Pain without Radiation,Vertebrogenic Pain Syndrome,Ache, Back,Aches, Back,Back Aches,Back Pains,Backaches,Pain Syndrome, Vertebrogenic,Pain Syndromes, Vertebrogenic,Pain, Back,Pains, Back,Syndrome, Vertebrogenic Pain,Syndromes, Vertebrogenic Pain,Vertebrogenic Pain Syndromes

Related Publications

G A Mirka
February 1986, Physical therapy,
G A Mirka
February 2013, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology,
G A Mirka
January 1987, Electroencephalography and clinical neurophysiology. Supplement,
G A Mirka
January 1987, Electroencephalography and clinical neurophysiology. Supplement,
G A Mirka
May 2002, Medicine and science in sports and exercise,
G A Mirka
October 2008, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology,
G A Mirka
December 2014, Journal of neurophysiology,
G A Mirka
December 1995, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology,
G A Mirka
July 2008, Medicine and science in sports and exercise,
Copied contents to your clipboard!