Response of the Panasonic UD803AS TLD in workplace neutron fields. 2008

L A Jones, and R P Stokes, and T Pinks
Defence Science and Technology Laboratory, Alverstoke, Gosport, Hants, UK.

Between 1983 and 2004, the United Kingdom Ministry of Defence (UK MOD) assessed photon and beta doses using the Panasonic UD803AS thermoluminescent dosemeter (TLD). The Panasonic UD803AS dosemeter is also sensitive to neutrons, and the aim of the present study was to ascertain whether dose assessments made using the Panasonic UD803AS TLD in UK MOD radiation fields include a conservative estimate of any neutron exposures. This would allow Panasonic UD803AS results to be taken as a measure of the total photon, beta and neutron dose when reconstructing dose records for the purpose of the 'Compensation Scheme for Radiation Linked Diseases'. The neutron response of the Panasonic UD803AS TLD was calculated as a function of neutron energy and angle of incidence by using the MCNP5 Monte Carlo computer code, and the results used to predict the response of the dosemeter in UK MOD neutron fields. It was found that the UD803AS dosemeter over-responded in the majority of these fields. It was therefore concluded that historical Panasonic UD803AS dose assessments will, for the most part, include a conservative estimate of any neutron exposure.

UI MeSH Term Description Entries
D008163 Luminescent Measurements Techniques used for determining the values of photometric parameters of light resulting from LUMINESCENCE. Bioluminescence Measurements,Bioluminescent Assays,Bioluminescent Measurements,Chemiluminescence Measurements,Chemiluminescent Assays,Chemiluminescent Measurements,Chemoluminescence Measurements,Luminescence Measurements,Luminescent Assays,Luminescent Techniques,Phosphorescence Measurements,Phosphorescent Assays,Phosphorescent Measurements,Assay, Bioluminescent,Assay, Chemiluminescent,Assay, Luminescent,Assay, Phosphorescent,Assays, Bioluminescent,Assays, Chemiluminescent,Assays, Luminescent,Assays, Phosphorescent,Bioluminescence Measurement,Bioluminescent Assay,Bioluminescent Measurement,Chemiluminescence Measurement,Chemiluminescent Assay,Chemiluminescent Measurement,Chemoluminescence Measurement,Luminescence Measurement,Luminescent Assay,Luminescent Measurement,Luminescent Technique,Measurement, Bioluminescence,Measurement, Bioluminescent,Measurement, Chemiluminescence,Measurement, Chemiluminescent,Measurement, Chemoluminescence,Measurement, Luminescence,Measurement, Luminescent,Measurement, Phosphorescence,Measurement, Phosphorescent,Measurements, Bioluminescence,Measurements, Bioluminescent,Measurements, Chemiluminescence,Measurements, Chemiluminescent,Measurements, Chemoluminescence,Measurements, Luminescence,Measurements, Luminescent,Measurements, Phosphorescence,Measurements, Phosphorescent,Phosphorescence Measurement,Phosphorescent Assay,Phosphorescent Measurement,Technique, Luminescent,Techniques, Luminescent
D009010 Monte Carlo Method In statistics, a technique for numerically approximating the solution of a mathematical problem by studying the distribution of some random variable, often generated by a computer. The name alludes to the randomness characteristic of the games of chance played at the gambling casinos in Monte Carlo. (From Random House Unabridged Dictionary, 2d ed, 1993) Method, Monte Carlo
D009502 Neutrons Electrically neutral elementary particles found in all atomic nuclei except light hydrogen; the mass is equal to that of the proton and electron combined and they are unstable when isolated from the nucleus, undergoing beta decay. Slow, thermal, epithermal, and fast neutrons refer to the energy levels with which the neutrons are ejected from heavier nuclei during their decay. Neutron
D011829 Radiation Dosage The amount of radiation energy that is deposited in a unit mass of material, such as tissues of plants or animal. In RADIOTHERAPY, radiation dosage is expressed in gray units (Gy). In RADIOLOGIC HEALTH, the dosage is expressed by the product of absorbed dose (Gy) and quality factor (a function of linear energy transfer), and is called radiation dose equivalent in sievert units (Sv). Sievert Units,Dosage, Radiation,Gray Units,Gy Radiation,Sv Radiation Dose Equivalent,Dosages, Radiation,Radiation Dosages,Units, Gray,Units, Sievert
D011834 Radiation Monitoring The observation, either continuously or at intervals, of the levels of radiation in a given area, generally for the purpose of assuring that they have not exceeded prescribed amounts or, in case of radiation already present in the area, assuring that the levels have returned to those meeting acceptable safety standards. Monitoring, Radiation
D011835 Radiation Protection Methods and practices adopted to protect against RADIATION. Protection, Radiation
D006113 United Kingdom Country in northwestern Europe including Great Britain and the northern one-sixth of the island of Ireland, located between the North Sea and north Atlantic Ocean. The capital is London. Great Britain,Isle of Man
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity
D013819 Thermoluminescent Dosimetry The use of a device composed of thermoluminescent material for measuring exposure to IONIZING RADIATION. The thermoluminescent material emits light when heated. The amount of light emitted is proportional to the amount of ionizing radiation to which the material has been exposed. Dosimetries, Thermoluminescent,Dosimetry, Thermoluminescent,Thermoluminescent Dosimetries

Related Publications

L A Jones, and R P Stokes, and T Pinks
April 2010, Health physics,
L A Jones, and R P Stokes, and T Pinks
January 2007, Radiation protection dosimetry,
L A Jones, and R P Stokes, and T Pinks
January 2007, Radiation protection dosimetry,
L A Jones, and R P Stokes, and T Pinks
January 2002, Radiation protection dosimetry,
L A Jones, and R P Stokes, and T Pinks
December 2020, Radiation protection dosimetry,
L A Jones, and R P Stokes, and T Pinks
January 2001, Radiation protection dosimetry,
L A Jones, and R P Stokes, and T Pinks
August 2018, Radiation protection dosimetry,
L A Jones, and R P Stokes, and T Pinks
January 2013, Medical physics,
L A Jones, and R P Stokes, and T Pinks
August 2019, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine,
L A Jones, and R P Stokes, and T Pinks
April 2012, Radiation protection dosimetry,
Copied contents to your clipboard!