Forward-masked spatial tuning curves in cochlear implant users. 2008

David A Nelson, and Gail S Donaldson, and Heather Kreft
Clinical Psychoacoustics Laboratory, Department of Otolaryngology, University of Minnesota, MMC396, 420 Delaware Street S.E., Minneapolis, Minnesota 55455, USA. dan@umn.edu

Forward-masked psychophysical spatial tuning curves (fmSTCs) were measured in twelve cochlear-implant subjects, six using bipolar stimulation (Nucleus devices) and six using monopolar stimulation (Clarion devices). fmSTCs were measured at several probe levels on a middle electrode using a fixed-level probe stimulus and variable-level maskers. The average fmSTC slopes obtained in subjects using bipolar stimulation (3.7 dBmm) were approximately three times steeper than average slopes obtained in subjects using monopolar stimulation (1.2 dBmm). Average spatial bandwidths were about half as wide for subjects with bipolar stimulation (2.6 mm) than for subjects with monopolar stimulation (4.6 mm). None of the tuning curve characteristics changed significantly with probe level. fmSTCs replotted in terms of acoustic frequency, using Greenwood's [J. Acoust. Soc. Am. 33, 1344-1356 (1961)] frequency-to-place equation, were compared with forward-masked psychophysical tuning curves obtained previously from normal-hearing and hearing-impaired acoustic listeners. The average tuning characteristics of fmSTCs in electric hearing were similar to the broad tuning observed in normal-hearing and hearing-impaired acoustic listeners at high stimulus levels. This suggests that spatial tuning is not the primary factor limiting speech perception in many cochlear implant users.

UI MeSH Term Description Entries
D010470 Perceptual Masking The interference of one perceptual stimulus with another causing a decrease or lessening in perceptual effectiveness. Masking, Perceptual,Maskings, Perceptual,Perceptual Maskings
D011474 Prosthesis Design The plan and delineation of prostheses in general or a specific prosthesis. Design, Prosthesis,Designs, Prosthesis,Prosthesis Designs
D003054 Cochlear Implants Electronic hearing devices typically used for patients with normal outer and middle ear function, but defective inner ear function. In the COCHLEA, the hair cells (HAIR CELLS, VESTIBULAR) may be absent or damaged but there are residual nerve fibers. The device electrically stimulates the COCHLEAR NERVE to create sound sensation. Auditory Prosthesis,Cochlear Prosthesis,Implants, Cochlear,Auditory Prostheses,Cochlear Implant,Cochlear Prostheses,Implant, Cochlear,Prostheses, Auditory,Prostheses, Cochlear,Prosthesis, Auditory,Prosthesis, Cochlear
D004566 Electrodes Electric conductors through which electric currents enter or leave a medium, whether it be an electrolytic solution, solid, molten mass, gas, or vacuum. Anode,Anode Materials,Cathode,Cathode Materials,Anode Material,Anodes,Cathode Material,Cathodes,Electrode,Material, Anode,Material, Cathode
D006309 Hearing The ability or act of sensing and transducing ACOUSTIC STIMULATION to the CENTRAL NERVOUS SYSTEM. It is also called audition. Audition
D006311 Hearing Disorders Conditions that impair the transmission of auditory impulses and information from the level of the ear to the temporal cortices, including the sensorineural pathways. Distorted Hearing,Dysacusis,Paracousis,Paracusis,Hearing Disorder,Hearing, Distorted
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000222 Adaptation, Physiological The non-genetic biological changes of an organism in response to challenges in its ENVIRONMENT. Adaptation, Physiologic,Adaptations, Physiologic,Adaptations, Physiological,Adaptive Plasticity,Phenotypic Plasticity,Physiological Adaptation,Physiologic Adaptation,Physiologic Adaptations,Physiological Adaptations,Plasticity, Adaptive,Plasticity, Phenotypic
D001299 Audiometry The testing of the acuity of the sense of hearing to determine the thresholds of the lowest intensity levels at which an individual can hear a set of tones. The frequencies between 125 and 8000 Hz are used to test air conduction thresholds and the frequencies between 250 and 4000 Hz are used to test bone conduction thresholds. Audiometries
D013997 Time Factors Elements of limited time intervals, contributing to particular results or situations. Time Series,Factor, Time,Time Factor

Related Publications

David A Nelson, and Gail S Donaldson, and Heather Kreft
January 2019, Trends in hearing,
David A Nelson, and Gail S Donaldson, and Heather Kreft
July 2011, The Journal of the Acoustical Society of America,
David A Nelson, and Gail S Donaldson, and Heather Kreft
September 2016, Trends in hearing,
David A Nelson, and Gail S Donaldson, and Heather Kreft
September 2016, The Journal of the Acoustical Society of America,
David A Nelson, and Gail S Donaldson, and Heather Kreft
April 2012, Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology,
David A Nelson, and Gail S Donaldson, and Heather Kreft
February 2017, Hearing research,
David A Nelson, and Gail S Donaldson, and Heather Kreft
June 2017, Journal of the Association for Research in Otolaryngology : JARO,
David A Nelson, and Gail S Donaldson, and Heather Kreft
November 1990, The Journal of the Acoustical Society of America,
David A Nelson, and Gail S Donaldson, and Heather Kreft
January 2020, Scientific reports,
David A Nelson, and Gail S Donaldson, and Heather Kreft
August 2009, Ear and hearing,
Copied contents to your clipboard!