Electrocardiogram voltage discordance: interpretation of low QRS voltage only in the limb leads. 2008

Jason S Chinitz, and Joshua M Cooper, and Ralph J Verdino
University of Pennsylvania School of Medicine, Philadelphia, PA, USA.

BACKGROUND Low voltage on the surface electrocardiogram (ECG) is defined as QRS voltage less than 5 mm in all limb leads and less than 10 mm in all precordial leads. The clinical correlate of an ECG with low voltage in the limb leads but normal precordial QRS amplitudes is unclear. METHODS Twelve-lead ECGs with QRS voltage less than 5 mm in all limb leads and more than 10 mm in at least 2 contiguous precordial leads were collected. Presence of clinical conditions associated with low voltage was determined from clinical data and chest imaging. RESULTS Fifty-one of 100 patients had voltage discordant ECGs that correlated with conditions known to cause diffuse low voltage. Among those without associated conditions, 63% had dilated ventricles, with an average ejection fraction of 33%. CONCLUSIONS Low voltage isolated to the limb leads is associated with the same conditions that cause diffuse low voltage in only half of patients. In the remainder, more than 60% have dilated cardiomyopathies.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D003937 Diagnosis, Differential Determination of which one of two or more diseases or conditions a patient is suffering from by systematically comparing and contrasting results of diagnostic measures. Diagnoses, Differential,Differential Diagnoses,Differential Diagnosis
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D004566 Electrodes Electric conductors through which electric currents enter or leave a medium, whether it be an electrolytic solution, solid, molten mass, gas, or vacuum. Anode,Anode Materials,Cathode,Cathode Materials,Anode Material,Anodes,Cathode Material,Cathodes,Electrode,Material, Anode,Material, Cathode
D005260 Female Females
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face
D018487 Ventricular Dysfunction, Left A condition in which the LEFT VENTRICLE of the heart was functionally impaired. This condition usually leads to HEART FAILURE; MYOCARDIAL INFARCTION; and other cardiovascular complications. Diagnosis is made by measuring the diminished ejection fraction and a depressed level of motility of the left ventricular wall. LV Diastolic Dysfunction,LV Dysfunction,LV Systolic Dysfunction,Left Ventricular Diastolic Dysfunction,Left Ventricular Dysfunction,Left Ventricular Systolic Dysfunction,Diastolic Dysfunction, LV,Dysfunction, LV,Dysfunction, LV Diastolic,Dysfunction, LV Systolic,Dysfunction, Left Ventricular,LV Diastolic Dysfunctions,LV Dysfunctions,LV Systolic Dysfunctions,Left Ventricular Dysfunctions,Systolic Dysfunction, LV

Related Publications

Jason S Chinitz, and Joshua M Cooper, and Ralph J Verdino
January 2017, Journal of electrocardiology,
Jason S Chinitz, and Joshua M Cooper, and Ralph J Verdino
January 2006, Journal of insurance medicine (New York, N.Y.),
Jason S Chinitz, and Joshua M Cooper, and Ralph J Verdino
October 2008, Proceedings (Baylor University. Medical Center),
Jason S Chinitz, and Joshua M Cooper, and Ralph J Verdino
December 2021, International journal of environmental research and public health,
Jason S Chinitz, and Joshua M Cooper, and Ralph J Verdino
March 2024, European journal of preventive cardiology,
Jason S Chinitz, and Joshua M Cooper, and Ralph J Verdino
December 1963, Medizinische Klinik,
Jason S Chinitz, and Joshua M Cooper, and Ralph J Verdino
January 2015, International journal of cardiology,
Jason S Chinitz, and Joshua M Cooper, and Ralph J Verdino
December 2015, International journal of cardiology,
Jason S Chinitz, and Joshua M Cooper, and Ralph J Verdino
July 1990, Clinical cardiology,
Copied contents to your clipboard!