Electron capture dissociation implementation progress in Fourier transform ion cyclotron resonance mass spectrometry. 2008

Yury O Tsybin, and John P Quinn, and Oleg Yu Tsybin, and Christopher L Hendrickson, and Alan G Marshall
Biomolecular Mass Spectrometry Laboratory, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland. yury.tsybin@epfl.ch

Successful electron capture dissociation (ECD) Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) applications to peptide and protein structural analysis have been enabled by constant progress in implementation of improved electron injection techniques. The rate of ECD product ion formation has been increased to match the liquid chromatography and capillary electrophoresis timescales, and ECD has been combined with infrared multiphoton dissociation in a single experimental configuration to provide simultaneous irradiation, fast switching between the two techniques, and good spatial overlap between ion, photon, and electron beams. Here we begin by describing advantages and disadvantages of the various existing electron injection techniques for ECD in FT-ICR MS. We next compare multiple-pass and single-pass ECD to provide better understanding of ECD efficiency at low and high negative cathode potentials. We introduce compressed hollow electron beam injection to optimize the overlap of ion, photon, and electron beams in the ICR ion trap. Finally, to overcome significant outgassing during operation of a powerful thermal cathode, we introduce nonthermal electron emitter-based electron injection. We describe the first results obtained with cold cathode ECD, and demonstrate a general way to obtain low-energy electrons in FT-ICR MS by use of multiple-pass ECD.

UI MeSH Term Description Entries
D007477 Ions An atom or group of atoms that have a positive or negative electric charge due to a gain (negative charge) or loss (positive charge) of one or more electrons. Atoms with a positive charge are known as CATIONS; those with a negative charge are ANIONS.
D004583 Electrons Stable elementary particles having the smallest known negative charge, present in all elements; also called negatrons. Positively charged electrons are called positrons. The numbers, energies and arrangement of electrons around atomic nuclei determine the chemical identities of elements. Beams of electrons are called CATHODE RAYS. Fast Electrons,Negatrons,Positrons,Electron,Electron, Fast,Electrons, Fast,Fast Electron,Negatron,Positron
D000465 Algorithms A procedure consisting of a sequence of algebraic formulas and/or logical steps to calculate or determine a given task. Algorithm
D017357 Cyclotrons Devices for accelerating charged particles in a spiral path by a constant-frequency alternating electric field. This electric field is synchronized with the movement of the particles in a constant magnetic field. Synchrocyclotrons,Cyclotron,Synchrocyclotron
D017550 Spectroscopy, Fourier Transform Infrared A spectroscopic technique in which a range of wavelengths is presented simultaneously with an interferometer and the spectrum is mathematically derived from the pattern thus obtained. FTIR,Fourier Transform Infrared Spectroscopy,Spectroscopy, Infrared, Fourier Transform
D021241 Spectrometry, Mass, Electrospray Ionization A mass spectrometry technique used for analysis of nonvolatile compounds such as proteins and macromolecules. The technique involves preparing electrically charged droplets from analyte molecules dissolved in solvent. The electrically charged droplets enter a vacuum chamber where the solvent is evaporated. Evaporation of solvent reduces the droplet size, thereby increasing the coulombic repulsion within the droplet. As the charged droplets get smaller, the excess charge within them causes them to disintegrate and release analyte molecules. The volatilized analyte molecules are then analyzed by mass spectrometry. ESI Mass Spectrometry,Electrospray Ionization Mass Spectrometry,Mass Spectrometry, ESI,Spectrometry, ESI Mass

Related Publications

Yury O Tsybin, and John P Quinn, and Oleg Yu Tsybin, and Christopher L Hendrickson, and Alan G Marshall
January 2002, Rapid communications in mass spectrometry : RCM,
Yury O Tsybin, and John P Quinn, and Oleg Yu Tsybin, and Christopher L Hendrickson, and Alan G Marshall
July 2005, Journal of the American Society for Mass Spectrometry,
Yury O Tsybin, and John P Quinn, and Oleg Yu Tsybin, and Christopher L Hendrickson, and Alan G Marshall
January 2004, Rapid communications in mass spectrometry : RCM,
Yury O Tsybin, and John P Quinn, and Oleg Yu Tsybin, and Christopher L Hendrickson, and Alan G Marshall
July 2004, Journal of mass spectrometry : JMS,
Yury O Tsybin, and John P Quinn, and Oleg Yu Tsybin, and Christopher L Hendrickson, and Alan G Marshall
January 2003, Rapid communications in mass spectrometry : RCM,
Yury O Tsybin, and John P Quinn, and Oleg Yu Tsybin, and Christopher L Hendrickson, and Alan G Marshall
March 1977, Science (New York, N.Y.),
Yury O Tsybin, and John P Quinn, and Oleg Yu Tsybin, and Christopher L Hendrickson, and Alan G Marshall
March 2005, Analytical chemistry,
Yury O Tsybin, and John P Quinn, and Oleg Yu Tsybin, and Christopher L Hendrickson, and Alan G Marshall
January 2001, Rapid communications in mass spectrometry : RCM,
Yury O Tsybin, and John P Quinn, and Oleg Yu Tsybin, and Christopher L Hendrickson, and Alan G Marshall
February 2006, The Analyst,
Yury O Tsybin, and John P Quinn, and Oleg Yu Tsybin, and Christopher L Hendrickson, and Alan G Marshall
January 2002, Rapid communications in mass spectrometry : RCM,
Copied contents to your clipboard!