On the calibration process of film dosimetry: OLS inverse regression versus WLS inverse prediction. 2008

F Crop, and B Van Rompaye, and L Paelinck, and L Vakaet, and H Thierens, and C De Wagter
Department of Medical Physics, Ghent University, Proeftuinstraat 86, B-9000 Gent, Belgium. Frederik.Crop@ugent.be

The purpose of this study was both putting forward a statistically correct model for film calibration and the optimization of this process. A reliable calibration is needed in order to perform accurate reference dosimetry with radiographic (Gafchromic) film. Sometimes, an ordinary least squares simple linear (in the parameters) regression is applied to the dose-optical-density (OD) curve with the dose as a function of OD (inverse regression) or sometimes OD as a function of dose (inverse prediction). The application of a simple linear regression fit is an invalid method because heteroscedasticity of the data is not taken into account. This could lead to erroneous results originating from the calibration process itself and thus to a lower accuracy. In this work, we compare the ordinary least squares (OLS) inverse regression method with the correct weighted least squares (WLS) inverse prediction method to create calibration curves. We found that the OLS inverse regression method could lead to a prediction bias of up to 7.3 cGy at 300 cGy and total prediction errors of 3% or more for Gafchromic EBT film. Application of the WLS inverse prediction method resulted in a maximum prediction bias of 1.4 cGy and total prediction errors below 2% in a 0-400 cGy range. We developed a Monte-Carlo-based process to optimize calibrations, depending on the needs of the experiment. This type of thorough analysis can lead to a higher accuracy for film dosimetry.

UI MeSH Term Description Entries
D012044 Regression Analysis Procedures for finding the mathematical function which best describes the relationship between a dependent variable and one or more independent variables. In linear regression (see LINEAR MODELS) the relationship is constrained to be a straight line and LEAST-SQUARES ANALYSIS is used to determine the best fit. In logistic regression (see LOGISTIC MODELS) the dependent variable is qualitative rather than continuously variable and LIKELIHOOD FUNCTIONS are used to find the best relationship. In multiple regression, the dependent variable is considered to depend on more than a single independent variable. Regression Diagnostics,Statistical Regression,Analysis, Regression,Analyses, Regression,Diagnostics, Regression,Regression Analyses,Regression, Statistical,Regressions, Statistical,Statistical Regressions
D002138 Calibration Determination, by measurement or comparison with a standard, of the correct value of each scale reading on a meter or other measuring instrument; or determination of the settings of a control device that correspond to particular values of voltage, current, frequency or other output. Calibrations
D005373 Film Dosimetry Use of a device (film badge) for measuring exposure of individuals to radiation. It is usually made of metal, plastic, or paper and loaded with one or more pieces of x-ray film. Film Badge Dosimetry,Film Badge,Badge Dosimetries, Film,Badge Dosimetry, Film,Badge, Film,Badges, Film,Dosimetries, Film,Dosimetries, Film Badge,Dosimetry, Film,Dosimetry, Film Badge,Film Badge Dosimetries,Film Badges,Film Dosimetries
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity
D016018 Least-Squares Analysis A principle of estimation in which the estimates of a set of parameters in a statistical model are those quantities minimizing the sum of squared differences between the observed values of a dependent variable and the values predicted by the model. Rietveld Refinement,Analysis, Least-Squares,Least Squares,Analyses, Least-Squares,Analysis, Least Squares,Least Squares Analysis,Least-Squares Analyses,Refinement, Rietveld
D016477 Artifacts Any visible result of a procedure which is caused by the procedure itself and not by the entity being analyzed. Common examples include histological structures introduced by tissue processing, radiographic images of structures that are not naturally present in living tissue, and products of chemical reactions that occur during analysis. Artefacts,Artefact,Artifact
D016526 Workload The total amount of work to be performed by an individual, a department, or other group of workers in a period of time. Employee Workload,Staff Workload,Employee Work Load,Staff Work Load,Work Load,Employee Work Loads,Employee Workloads,Staff Work Loads,Staff Workloads,Work Load, Employee,Work Load, Staff,Work Loads,Work Loads, Employee,Work Loads, Staff,Workload, Employee,Workload, Staff,Workloads,Workloads, Employee,Workloads, Staff

Related Publications

F Crop, and B Van Rompaye, and L Paelinck, and L Vakaet, and H Thierens, and C De Wagter
October 2017, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB),
F Crop, and B Van Rompaye, and L Paelinck, and L Vakaet, and H Thierens, and C De Wagter
January 1994, Medical dosimetry : official journal of the American Association of Medical Dosimetrists,
F Crop, and B Van Rompaye, and L Paelinck, and L Vakaet, and H Thierens, and C De Wagter
December 2011, Talanta,
F Crop, and B Van Rompaye, and L Paelinck, and L Vakaet, and H Thierens, and C De Wagter
January 2020, Physics in medicine and biology,
F Crop, and B Van Rompaye, and L Paelinck, and L Vakaet, and H Thierens, and C De Wagter
January 2010, Water science and technology : a journal of the International Association on Water Pollution Research,
F Crop, and B Van Rompaye, and L Paelinck, and L Vakaet, and H Thierens, and C De Wagter
September 2009, Cardiopulmonary physical therapy journal,
F Crop, and B Van Rompaye, and L Paelinck, and L Vakaet, and H Thierens, and C De Wagter
August 2018, Radiation protection dosimetry,
F Crop, and B Van Rompaye, and L Paelinck, and L Vakaet, and H Thierens, and C De Wagter
March 1968, Strahlentherapie,
F Crop, and B Van Rompaye, and L Paelinck, and L Vakaet, and H Thierens, and C De Wagter
January 1968, Health physics,
F Crop, and B Van Rompaye, and L Paelinck, and L Vakaet, and H Thierens, and C De Wagter
May 2007, Medical physics,
Copied contents to your clipboard!