Fluorimetric determination of mexiletine in serum by high-performance liquid chromatography using pre-column derivatization with fluorescamine. 1991

N Shibata, and M Akabane, and T Minouchi, and T Ono, and H Shimakawa
Hospital Pharmacy, Shiga University of Medical Science, Ohtsu, Japan.

A simple, specific and sensitive micro-scale method for the assay of the antiarrhythmic agent mexiletine in human serum is described. The method uses high-performance liquid chromatography, with pre-column fluorimetric derivatization by fluorescamine. Following extraction with diethyl ether, mexiletine and 4-methylmexiletine (an internal standard) were derivatized with fluorescamine under weakly alkaline condition (pH 9.0) and chromatographed on a reversed-phase column with aqueous methanol-2-propanol as the mobile phase. The two fluorescent derivatives of mexiletine and the internal standard were separated as clear single peaks, and no interfering peaks were observed on the chromatograms. The detection limit for mexiletine was 0.005 micrograms/ml from only 100 microliters of serum, and the calibration curves in the range 0.01-5 micrograms/ml were linear, with an overall coefficient of variation of less than 5%. The analytical recovery of a known amount of mexiletine added to serum was almost 100%. This method proved to be effective in the rapid monitoring of the serum concentrations in patients who received this potent antiarrhythmic drug.

UI MeSH Term Description Entries
D007700 Kinetics The rate dynamics in chemical or physical systems.
D008801 Mexiletine Antiarrhythmic agent pharmacologically similar to LIDOCAINE. It may have some anticonvulsant properties. KO-1173,KO1173,KOE-1173,Mexiletene,Mexiletine Hydrochloride,Mexitil,Mexitil PL,Mexityl,Novo-Mexiletine,KO 1173,KOE 1173,KOE1173,Novo Mexiletine
D002851 Chromatography, High Pressure Liquid Liquid chromatographic techniques which feature high inlet pressures, high sensitivity, and high speed. Chromatography, High Performance Liquid,Chromatography, High Speed Liquid,Chromatography, Liquid, High Pressure,HPLC,High Performance Liquid Chromatography,High-Performance Liquid Chromatography,UPLC,Ultra Performance Liquid Chromatography,Chromatography, High-Performance Liquid,High-Performance Liquid Chromatographies,Liquid Chromatography, High-Performance
D005450 Fluorescamine A nonfluorescent reagent for the detection of primary amines, peptides and proteins. The reaction products are highly fluorescent. Fluram
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000889 Anti-Arrhythmia Agents Agents used for the treatment or prevention of cardiac arrhythmias. They may affect the polarization-repolarization phase of the action potential, its excitability or refractoriness, or impulse conduction or membrane responsiveness within cardiac fibers. Anti-arrhythmia agents are often classed into four main groups according to their mechanism of action: sodium channel blockade, beta-adrenergic blockade, repolarization prolongation, or calcium channel blockade. Anti-Arrhythmia Agent,Anti-Arrhythmia Drug,Anti-Arrhythmic,Antiarrhythmia Agent,Antiarrhythmia Drug,Antiarrhythmic Drug,Antifibrillatory Agent,Antifibrillatory Agents,Cardiac Depressant,Cardiac Depressants,Myocardial Depressant,Myocardial Depressants,Anti-Arrhythmia Drugs,Anti-Arrhythmics,Antiarrhythmia Agents,Antiarrhythmia Drugs,Antiarrhythmic Drugs,Agent, Anti-Arrhythmia,Agent, Antiarrhythmia,Agent, Antifibrillatory,Agents, Anti-Arrhythmia,Agents, Antiarrhythmia,Agents, Antifibrillatory,Anti Arrhythmia Agent,Anti Arrhythmia Agents,Anti Arrhythmia Drug,Anti Arrhythmia Drugs,Anti Arrhythmic,Anti Arrhythmics,Depressant, Cardiac,Depressant, Myocardial,Depressants, Cardiac,Depressants, Myocardial,Drug, Anti-Arrhythmia,Drug, Antiarrhythmia,Drug, Antiarrhythmic,Drugs, Anti-Arrhythmia,Drugs, Antiarrhythmia,Drugs, Antiarrhythmic

Related Publications

N Shibata, and M Akabane, and T Minouchi, and T Ono, and H Shimakawa
February 1993, Journal of chromatography,
N Shibata, and M Akabane, and T Minouchi, and T Ono, and H Shimakawa
April 1987, Journal of chromatography,
N Shibata, and M Akabane, and T Minouchi, and T Ono, and H Shimakawa
July 1991, Journal of chromatography,
N Shibata, and M Akabane, and T Minouchi, and T Ono, and H Shimakawa
January 1984, Journal of chromatography,
N Shibata, and M Akabane, and T Minouchi, and T Ono, and H Shimakawa
December 1988, Journal of chromatography,
N Shibata, and M Akabane, and T Minouchi, and T Ono, and H Shimakawa
November 2010, Se pu = Chinese journal of chromatography,
N Shibata, and M Akabane, and T Minouchi, and T Ono, and H Shimakawa
February 2009, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences,
N Shibata, and M Akabane, and T Minouchi, and T Ono, and H Shimakawa
September 1989, Biomedical chromatography : BMC,
N Shibata, and M Akabane, and T Minouchi, and T Ono, and H Shimakawa
April 1998, Journal of chromatography. B, Biomedical sciences and applications,
Copied contents to your clipboard!