Extracting respiratory data from pulse oximeter plethysmogram traces in newborn infants. 2009

D Wertheim, and C Olden, and E Savage, and P Seddon
Kingston University, Kingston, UK.

To investigate whether valid respiratory data can be extracted from the pulse oximeter plethysmographic (pleth) trace in healthy newborn infants, pleth data were collected from the foot, and respiratory airflow was simultaneously measured using a facemask. The pleth waveform was analysed using fast Fourier transform (FFT), low-pass filtering (LPF), and by plotting the peak-to-peak amplitude variation (PtP). Using FFT in 14 term infants, the median (range) respiratory rate from the pleth signal was 43 (30-65) breaths/min, and from the flow signal it was 44 (30-67) breaths/min (median difference 0.01 breaths/min, p>0.05). Both LPF and PtP analysis yielded waveforms with a frequency similar to the respiratory rate. Respiratory information, including respiratory rate and a respiratory-like waveform, can reliably be extracted from the pleth trace of a standard pulse oximeter in newborn infants. Such analysis may be clinically useful for non-invasive assessment of respiratory problems in infants and young children.

UI MeSH Term Description Entries
D007231 Infant, Newborn An infant during the first 28 days after birth. Neonate,Newborns,Infants, Newborn,Neonates,Newborn,Newborn Infant,Newborn Infants
D008991 Monitoring, Physiologic The continuous measurement of physiological processes, blood pressure, heart rate, renal output, reflexes, respiration, etc., in a patient or experimental animal; includes pharmacologic monitoring, the measurement of administered drugs or their metabolites in the blood, tissues, or urine. Patient Monitoring,Monitoring, Physiological,Physiologic Monitoring,Monitoring, Patient,Physiological Monitoring
D010092 Oximetry The determination of oxygen-hemoglobin saturation of blood either by withdrawing a sample and passing it through a classical photoelectric oximeter or by electrodes attached to some translucent part of the body like finger, earlobe, or skin fold. It includes non-invasive oxygen monitoring by pulse oximetry. Pulse Oximetry,Oximetry, Pulse,Oximetries,Oximetries, Pulse,Pulse Oximetries
D010991 Plethysmography Recording of change in the size of a part as modified by the circulation in it. Plethysmographies
D001724 Birth Weight The mass or quantity of heaviness of an individual at BIRTH. It is expressed by units of pounds or kilograms. Birthweight,Birth Weights,Birthweights,Weight, Birth,Weights, Birth
D005240 Feasibility Studies Studies to determine the advantages or disadvantages, practicability, or capability of accomplishing a projected plan, study, or project. Feasibility Study,Studies, Feasibility,Study, Feasibility
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D012815 Signal Processing, Computer-Assisted Computer-assisted processing of electric, ultrasonic, or electronic signals to interpret function and activity. Digital Signal Processing,Signal Interpretation, Computer-Assisted,Signal Processing, Digital,Computer-Assisted Signal Interpretation,Computer-Assisted Signal Interpretations,Computer-Assisted Signal Processing,Interpretation, Computer-Assisted Signal,Interpretations, Computer-Assisted Signal,Signal Interpretation, Computer Assisted,Signal Interpretations, Computer-Assisted,Signal Processing, Computer Assisted
D015656 Respiratory Mechanics The physical or mechanical action of the LUNGS; DIAPHRAGM; RIBS; and CHEST WALL during respiration. It includes airflow, lung volume, neural and reflex controls, mechanoreceptors, breathing patterns, etc. Breathing Mechanics,Breathing Mechanic,Mechanic, Breathing,Mechanic, Respiratory,Mechanics, Breathing,Mechanics, Respiratory,Respiratory Mechanic

Related Publications

D Wertheim, and C Olden, and E Savage, and P Seddon
June 2001, Anaesthesia,
D Wertheim, and C Olden, and E Savage, and P Seddon
January 2004, Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference,
D Wertheim, and C Olden, and E Savage, and P Seddon
August 2015, Journal of perinatology : official journal of the California Perinatal Association,
D Wertheim, and C Olden, and E Savage, and P Seddon
November 2011, Physiological measurement,
D Wertheim, and C Olden, and E Savage, and P Seddon
June 1952, Pediatrics,
D Wertheim, and C Olden, and E Savage, and P Seddon
March 1990, Anesthesia and analgesia,
D Wertheim, and C Olden, and E Savage, and P Seddon
December 2001, Anesthesia and analgesia,
D Wertheim, and C Olden, and E Savage, and P Seddon
January 2022, Journal of perinatology : official journal of the California Perinatal Association,
D Wertheim, and C Olden, and E Savage, and P Seddon
June 2003, Nihon Kokyuki Gakkai zasshi = the journal of the Japanese Respiratory Society,
D Wertheim, and C Olden, and E Savage, and P Seddon
June 1986, Ma zui xue za zhi = Anaesthesiologica Sinica,
Copied contents to your clipboard!