A simple and sensitive HPLC-ESI-MS/MS method for the determination of andrographolide in human plasma. 2009

Li Xu, and Da-wei Xiao, and Sheng Lou, and Jian-jun Zou, and Yu-bing Zhu, and Hong-wei Fan, and Guang-ji Wang
Department of Pharmacology, NanJing Traditional Chinese medicine University, Nanjing 210046, China.

A liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS) method for the determination of andrographolide in human plasma was established. Dehydroandrographolide was used as the internal standard (I.S.). The plasma samples were deproteinized with methanol and separated on a Hanbon C(18) column with a mobile phase of methanol-water (70:30, v/v). HPLC-ESI-MS/MS was performed in the selected ion monitoring (SIM) mode using target ions at [M-H(2)O-H](-), m/z 331.1 for andrographolide and [M-H](-), m/z 331.1 for the I.S. Calibration curve was linear over the range of 1.0-150.0ng/mL. The chromatographic separation was achieved in less than 6.5min. The lower limits of quantification (LLOQ) was 1.0ng/mL. The intra and inter-run precisions were less than 6.95 and 7.22%, respectively. The method was successfully applied to determine the plasma concentrations of andrographolide in Chinese volunteers.

UI MeSH Term Description Entries
D008297 Male Males
D012015 Reference Standards A basis of value established for the measure of quantity, weight, extent or quality, e.g. weight standards, standard solutions, methods, techniques, and procedures used in diagnosis and therapy. Standard Preparations,Standards, Reference,Preparations, Standard,Standardization,Standards,Preparation, Standard,Reference Standard,Standard Preparation,Standard, Reference
D002138 Calibration Determination, by measurement or comparison with a standard, of the correct value of each scale reading on a meter or other measuring instrument; or determination of the settings of a control device that correspond to particular values of voltage, current, frequency or other output. Calibrations
D002851 Chromatography, High Pressure Liquid Liquid chromatographic techniques which feature high inlet pressures, high sensitivity, and high speed. Chromatography, High Performance Liquid,Chromatography, High Speed Liquid,Chromatography, Liquid, High Pressure,HPLC,High Performance Liquid Chromatography,High-Performance Liquid Chromatography,UPLC,Ultra Performance Liquid Chromatography,Chromatography, High-Performance Liquid,High-Performance Liquid Chromatographies,Liquid Chromatography, High-Performance
D004224 Diterpenes Twenty-carbon compounds derived from MEVALONIC ACID or deoxyxylulose phosphate. Diterpene,Diterpenes, Cembrane,Diterpenes, Labdane,Diterpenoid,Labdane Diterpene,Norditerpene,Norditerpenes,Norditerpenoid,Cembranes,Diterpenoids,Labdanes,Norditerpenoids,Cembrane Diterpenes,Diterpene, Labdane,Labdane Diterpenes
D004355 Drug Stability The chemical and physical integrity of a pharmaceutical product. Drug Shelf Life,Drugs Shelf Lives,Shelf Life, Drugs,Drug Stabilities,Drugs Shelf Life,Drugs Shelf Live,Life, Drugs Shelf,Shelf Life, Drug,Shelf Live, Drugs,Shelf Lives, Drugs
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000893 Anti-Inflammatory Agents Substances that reduce or suppress INFLAMMATION. Anti-Inflammatory Agent,Antiinflammatory Agent,Agents, Anti-Inflammatory,Agents, Antiinflammatory,Anti-Inflammatories,Antiinflammatories,Antiinflammatory Agents,Agent, Anti-Inflammatory,Agent, Antiinflammatory,Agents, Anti Inflammatory,Anti Inflammatories,Anti Inflammatory Agent,Anti Inflammatory Agents
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face
D021241 Spectrometry, Mass, Electrospray Ionization A mass spectrometry technique used for analysis of nonvolatile compounds such as proteins and macromolecules. The technique involves preparing electrically charged droplets from analyte molecules dissolved in solvent. The electrically charged droplets enter a vacuum chamber where the solvent is evaporated. Evaporation of solvent reduces the droplet size, thereby increasing the coulombic repulsion within the droplet. As the charged droplets get smaller, the excess charge within them causes them to disintegrate and release analyte molecules. The volatilized analyte molecules are then analyzed by mass spectrometry. ESI Mass Spectrometry,Electrospray Ionization Mass Spectrometry,Mass Spectrometry, ESI,Spectrometry, ESI Mass

Related Publications

Li Xu, and Da-wei Xiao, and Sheng Lou, and Jian-jun Zou, and Yu-bing Zhu, and Hong-wei Fan, and Guang-ji Wang
January 2008, Journal of chromatographic science,
Li Xu, and Da-wei Xiao, and Sheng Lou, and Jian-jun Zou, and Yu-bing Zhu, and Hong-wei Fan, and Guang-ji Wang
October 2010, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences,
Li Xu, and Da-wei Xiao, and Sheng Lou, and Jian-jun Zou, and Yu-bing Zhu, and Hong-wei Fan, and Guang-ji Wang
November 2006, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences,
Li Xu, and Da-wei Xiao, and Sheng Lou, and Jian-jun Zou, and Yu-bing Zhu, and Hong-wei Fan, and Guang-ji Wang
July 2010, Journal of chromatographic science,
Li Xu, and Da-wei Xiao, and Sheng Lou, and Jian-jun Zou, and Yu-bing Zhu, and Hong-wei Fan, and Guang-ji Wang
May 2008, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences,
Li Xu, and Da-wei Xiao, and Sheng Lou, and Jian-jun Zou, and Yu-bing Zhu, and Hong-wei Fan, and Guang-ji Wang
January 2014, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences,
Li Xu, and Da-wei Xiao, and Sheng Lou, and Jian-jun Zou, and Yu-bing Zhu, and Hong-wei Fan, and Guang-ji Wang
November 2012, Biomedical chromatography : BMC,
Li Xu, and Da-wei Xiao, and Sheng Lou, and Jian-jun Zou, and Yu-bing Zhu, and Hong-wei Fan, and Guang-ji Wang
November 2012, Talanta,
Li Xu, and Da-wei Xiao, and Sheng Lou, and Jian-jun Zou, and Yu-bing Zhu, and Hong-wei Fan, and Guang-ji Wang
March 2011, Journal of mass spectrometry : JMS,
Li Xu, and Da-wei Xiao, and Sheng Lou, and Jian-jun Zou, and Yu-bing Zhu, and Hong-wei Fan, and Guang-ji Wang
June 2007, Journal of pharmaceutical and biomedical analysis,
Copied contents to your clipboard!