Reliability of audiometric thresholds obtained with insert earphones when used by certified audiometric technicians. 2009

Barbara Bell-Lehmkuhler, and Deanna K Meinke, and Allison Sedey, and Cassie Tuell
RidgeGate Hearing Clinic, CO 80124, USA. bbell@integratedent.com

Clinical audiologists and audiometric equipment manufacturers have embraced the clinical use of insert earphones; however, their use in audiometric testing in occupational hearing loss prevention programs has been limited. This study was undertaken to research whether certified audiometric technicians without practical hands-on training could reliably use insert earphones when compared to a clinically experienced audiologist. Hearing thresholds were obtained on 60 human ears by six certified audiometric technicians using insert earphones for the first time. Technician-acquired audiometric thresholds were compared to thresholds obtained under the same conditions by a clinical audiologist experienced in the use of the insert earphones. Statistical analyses of audiometric thresholds were performed to investigate the relationships between audiometric threshold values at each frequency obtained by certified technicians vs. the audiologist. These relationships were examined for the group as a whole as well as when ear tip size and earphone insertion depth varied between the audiologist and the technicians. No significant differences (p > .01) were found between mean group thresholds at any of the test frequencies (500-8000 Hz). Mean group thresholds differed by < 1.2 dB. Pearson Product-Moment correlation (PPMC) coefficients suggested that thresholds obtained by the audiometric technician were highly correlated with those obtained by the audiologist. There were no significant threshold differences (p > .01) even when the audiologist and technicians varied in their selection of ear tip size or in the amount of insertion depth achieved. This study suggests that CAOHC-certified audiometric technicians can reliably use insert earphones without practical training when testing in quiet environments by reading the earphone package directions provided by the manufacturer.

UI MeSH Term Description Entries
D003627 Data Interpretation, Statistical Application of statistical procedures to analyze specific observed or assumed facts from a particular study. Data Analysis, Statistical,Data Interpretations, Statistical,Interpretation, Statistical Data,Statistical Data Analysis,Statistical Data Interpretation,Analyses, Statistical Data,Analysis, Statistical Data,Data Analyses, Statistical,Interpretations, Statistical Data,Statistical Data Analyses,Statistical Data Interpretations
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D006320 Hearing Tests Part of an ear examination that measures the ability of sound to reach the brain. Hearing in Noise Test,Quick Speech-in Noise Test (QuickSIN),Real Ear Measurement,Speech in Noise Hearing Test,Ear Measurement, Real,Ear Measurements, Real,Hearing Test,Measurement, Real Ear,Measurements, Real Ear,Quick Speech in Noise Test (QuickSIN),Real Ear Measurements,Test, Hearing,Tests, Hearing
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000078329 Workforce The number of people working or available for work or service. Human Resources,Labor Supply,Manpower,Staffing,Womanpower,Human Resource,Labor Supplies,Manpowers,Staffings,Supply, Labor,Womanpowers,Workforces
D001298 Audiology Allied medical specialty that studies hearing and hearing impairment.
D001299 Audiometry The testing of the acuity of the sense of hearing to determine the thresholds of the lowest intensity levels at which an individual can hear a set of tones. The frequencies between 125 and 8000 Hz are used to test air conduction thresholds and the frequencies between 250 and 4000 Hz are used to test bone conduction thresholds. Audiometries
D001309 Auditory Threshold The audibility limit of discriminating sound intensity and pitch. Auditory Thresholds,Threshold, Auditory,Thresholds, Auditory

Related Publications

Barbara Bell-Lehmkuhler, and Deanna K Meinke, and Allison Sedey, and Cassie Tuell
January 1991, Scandinavian audiology,
Barbara Bell-Lehmkuhler, and Deanna K Meinke, and Allison Sedey, and Cassie Tuell
January 1997, Scandinavian audiology,
Barbara Bell-Lehmkuhler, and Deanna K Meinke, and Allison Sedey, and Cassie Tuell
January 1997, American journal of primatology,
Barbara Bell-Lehmkuhler, and Deanna K Meinke, and Allison Sedey, and Cassie Tuell
December 2015, American journal of audiology,
Barbara Bell-Lehmkuhler, and Deanna K Meinke, and Allison Sedey, and Cassie Tuell
January 1991, Audiology : official organ of the International Society of Audiology,
Barbara Bell-Lehmkuhler, and Deanna K Meinke, and Allison Sedey, and Cassie Tuell
September 2019, The international tinnitus journal,
Barbara Bell-Lehmkuhler, and Deanna K Meinke, and Allison Sedey, and Cassie Tuell
March 2014, International journal of audiology,
Barbara Bell-Lehmkuhler, and Deanna K Meinke, and Allison Sedey, and Cassie Tuell
October 2010, International journal of audiology,
Barbara Bell-Lehmkuhler, and Deanna K Meinke, and Allison Sedey, and Cassie Tuell
January 1990, Scandinavian audiology,
Barbara Bell-Lehmkuhler, and Deanna K Meinke, and Allison Sedey, and Cassie Tuell
March 2004, The Journal of the Acoustical Society of America,
Copied contents to your clipboard!