Optical calibration for both out-of-plane and in-plane displacement sensitivity of acoustic emission sensors. 2009

P D Theobald
National Physical Laboratory, Hampton Road, Teddington, Middlesex TW11 0LW, UK. pete.theobald@npl.co.uk

The use of piezoelectric sensors for acoustic emission (AE) monitoring provides an extremely sensitive detection method of AE events. The sensors are used to detect the stress waves, resulting from an AE event, which arrive at the surface of a structure. The sensors provide high sensitivity, and are generally based on a high-Q design where the sensor is used to detect AE events around its resonance. Sensitivity calibration of these sensors is essential for accurate assessment of the AE measurement and particularly important for sensors mounted on safety critical structures. This paper proposes an optical method which enables both the out-of-plane and in-plane displacement sensitivity of an AE sensor to be established independently from each other. In the method, a laser homodyne interferometer is used to measure the out-of-plane and in-plane displacement of the surface of a large test block excited by a repeatable source transducer. The out-of-plane displacement is measured by aligning the laser beam perpendicular to the surface with time gating of the receive waveform used to isolate only the direct arrival of the longitudinal wave produced by the piston source transducer. For the in-plane displacement measurement, the laser beam is aligned parallel to the surface to intersect a small optically reflective step with the time waveform being gated to measure only the direct shear arrival produced using a normal incidence shear wave source transducer. In each case, the interferometer measurement is followed by coupling the sensor under test to the measurement surface, which is then exposed to the same acoustic field and the sensor output signal measured. This substitution method allows the sensor sensitivity to be obtained in terms of volts per unit displacement for both the out-of-plane and the in-plane surface displacement. The method provides a comprehensive description of an AE sensor response to different planes of displacement and offers the potential for a traceable sensor calibration to units of length.

UI MeSH Term Description Entries
D002138 Calibration Determination, by measurement or comparison with a standard, of the correct value of each scale reading on a meter or other measuring instrument; or determination of the settings of a control device that correspond to particular values of voltage, current, frequency or other output. Calibrations
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D000162 Acoustics The branch of physics that deals with sound and sound waves. In medicine it is often applied in procedures in speech and hearing studies. With regard to the environment, it refers to the characteristics of a room, auditorium, theatre, building, etc. that determines the audibility or fidelity of sounds in it. (From Random House Unabridged Dictionary, 2d ed) Acoustic
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity
D014159 Transducers Any device or element which converts an input signal into an output signal of a different form. Examples include the microphone, phonographic pickup, loudspeaker, barometer, photoelectric cell, automobile horn, doorbell, and underwater sound transducer. (McGraw Hill Dictionary of Scientific and Technical Terms, 4th ed) Transducer
D014463 Ultrasonography The visualization of deep structures of the body by recording the reflections or echoes of ultrasonic pulses directed into the tissues. Use of ultrasound for imaging or diagnostic purposes employs frequencies ranging from 1.6 to 10 megahertz. Echography,Echotomography,Echotomography, Computer,Sonography, Medical,Tomography, Ultrasonic,Ultrasonic Diagnosis,Ultrasonic Imaging,Ultrasonographic Imaging,Computer Echotomography,Diagnosis, Ultrasonic,Diagnostic Ultrasound,Ultrasonic Tomography,Ultrasound Imaging,Diagnoses, Ultrasonic,Diagnostic Ultrasounds,Imaging, Ultrasonic,Imaging, Ultrasonographic,Imaging, Ultrasound,Imagings, Ultrasonographic,Imagings, Ultrasound,Medical Sonography,Ultrasonic Diagnoses,Ultrasonographic Imagings,Ultrasound, Diagnostic,Ultrasounds, Diagnostic
D014732 Vibration A continuing periodic change in displacement with respect to a fixed reference. (McGraw-Hill Dictionary of Scientific and Technical Terms, 6th ed) Vibrations
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face
D017076 Computer-Aided Design The use of computers for designing and/or manufacturing of anything, including drugs, surgical procedures, orthotics, and prosthetics. CAD-CAM,Computer-Aided Manufacturing,Computer-Assisted Design,Computer-Assisted Manufacturing,Computer Aided Design,Computer Aided Manufacturing,Computer Assisted Design,Computer Assisted Manufacturing,Computer-Aided Designs,Computer-Assisted Designs,Design, Computer-Aided,Design, Computer-Assisted,Designs, Computer-Aided,Designs, Computer-Assisted,Manufacturing, Computer-Aided,Manufacturing, Computer-Assisted
D055096 Optical Devices Products or parts of products used to detect, manipulate, or analyze light, such as LENSES, refractors, mirrors, filters, prisms, and OPTICAL FIBERS. Optical Components,Optical System,Component, Optical,Components, Optical,Device, Optical,Devices, Optical,Optical Component,Optical Device,Optical Systems,System, Optical,Systems, Optical