Thallium 201 for assessment of myocardial viability. 1991

R O Bonow, and V Dilsizian
Cardiology Branch, National Heart, Lung, and Blood Institute, Bethesda, MD 20892.

Left ventricular (LV) performance is reduced in a large subset of patients with chronic coronary artery disease (CAD) and LV dysfunction on the basis of regionally ischemic or hibernating myocardium rather than irreversibly infarcted tissue. The detection of dysfunctional but viable myocardium is clinically relevant since regional and global LV function in such patients will improve after revascularization procedures; however, the identification of patients with such potentially reversible LV dysfunction is difficult. Although thallium 201 imaging may be of value in detecting viable myocardium if regions with perfusion defects during exercise demonstrate redistribution of thallium on a 3- to 4-hour resting image, thallium defects often appear persistently "fixed" within regions of severely ischemic or hibernating myocardium. It has been shown that up to 50% of regions with apparently irreversible thallium defects will improve in function after revascularization. Thus, standard exercise-redistribution thallium scintigraphy may not differentiate LV dysfunction arising from infarcted versus hibernating myocardium. The precision with which thallium imaging identifies viable myocardium can be improved greatly by additional studies once 4-hour redistribution imaging demonstrates an irreversible thallium defect. These additional studies include late (24-hour) redistribution imaging, repeat imaging after thallium reinjection, or a combination of thallium reinjection followed by late imaging. Several recent studies suggest that thallium reinjection techniques, by demonstrating thallium uptake in dysfunctional regions with apparently irreversible defects, predict improvement after revascularization with similar predictive accuracy as that achieved using metabolic imaging with positron emission tomography (PET). Studies directly comparing such thallium methods and PET, which thus far involve only small numbers of patients, suggest that the assessment of regional metabolic activity using PET and the assessment of regional thallium activity using single photon emission computed tomography provide concordant results. These findings, if confirmed by larger ongoing studies, suggest that thallium reinjection imaging is a convenient, clinically accurate, and relatively inexpensive method with which to identify viable myocardium in patients with chronic CAD and LV dysfunction.

UI MeSH Term Description Entries
D003327 Coronary Disease An imbalance between myocardial functional requirements and the capacity of the CORONARY VESSELS to supply sufficient blood flow. It is a form of MYOCARDIAL ISCHEMIA (insufficient blood supply to the heart muscle) caused by a decreased capacity of the coronary vessels. Coronary Heart Disease,Coronary Diseases,Coronary Heart Diseases,Disease, Coronary,Disease, Coronary Heart,Diseases, Coronary,Diseases, Coronary Heart,Heart Disease, Coronary,Heart Diseases, Coronary
D006321 Heart The hollow, muscular organ that maintains the circulation of the blood. Hearts
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D013794 Thallium Radioisotopes Unstable isotopes of thallium that decay or disintegrate emitting radiation. Tl atoms with atomic weights 198-202, 204, and 206-210 are thallium radioisotopes. Radioisotopes, Thallium
D014055 Tomography, Emission-Computed Tomography using radioactive emissions from injected RADIONUCLIDES and computer ALGORITHMS to reconstruct an image. CAT Scan, Radionuclide,CT Scan, Radionuclide,Computerized Emission Tomography,Radionuclide Tomography, Computed,Scintigraphy, Computed Tomographic,Tomography, Radionuclide-Computed,Computed Tomographic Scintigraphy,Emission-Computed Tomography,Radionuclide Computer-Assisted Tomography,Radionuclide Computerized Tomography,Radionuclide-Computed Tomography,Radionuclide-Emission Computed Tomography,Tomography, Computerized Emission,CAT Scans, Radionuclide,CT Scans, Radionuclide,Computed Radionuclide Tomography,Computed Tomography, Radionuclide-Emission,Computer-Assisted Tomographies, Radionuclide,Computer-Assisted Tomography, Radionuclide,Computerized Tomography, Radionuclide,Emission Computed Tomography,Emission Tomography, Computerized,Radionuclide CAT Scan,Radionuclide CAT Scans,Radionuclide CT Scan,Radionuclide CT Scans,Radionuclide Computed Tomography,Radionuclide Computer Assisted Tomography,Radionuclide Computer-Assisted Tomographies,Radionuclide Emission Computed Tomography,Scan, Radionuclide CAT,Scan, Radionuclide CT,Scans, Radionuclide CAT,Scans, Radionuclide CT,Tomographic Scintigraphy, Computed,Tomographies, Radionuclide Computer-Assisted,Tomography, Computed Radionuclide,Tomography, Emission Computed,Tomography, Radionuclide Computed,Tomography, Radionuclide Computer-Assisted,Tomography, Radionuclide Computerized,Tomography, Radionuclide-Emission Computed
D015899 Tomography, Emission-Computed, Single-Photon A method of computed tomography that uses radionuclides which emit a single photon of a given energy. The camera is rotated 180 or 360 degrees around the patient to capture images at multiple positions along the arc. The computer is then used to reconstruct the transaxial, sagittal, and coronal images from the 3-dimensional distribution of radionuclides in the organ. The advantages of SPECT are that it can be used to observe biochemical and physiological processes as well as size and volume of the organ. The disadvantage is that, unlike positron-emission tomography where the positron-electron annihilation results in the emission of 2 photons at 180 degrees from each other, SPECT requires physical collimation to line up the photons, which results in the loss of many available photons and hence degrades the image. CAT Scan, Single-Photon Emission,CT Scan, Single-Photon Emission,Radionuclide Tomography, Single-Photon Emission-Computed,SPECT,Single-Photon Emission-Computed Tomography,Tomography, Single-Photon, Emission-Computed,Single-Photon Emission CT Scan,Single-Photon Emission Computer-Assisted Tomography,Single-Photon Emission Computerized Tomography,CAT Scan, Single Photon Emission,CT Scan, Single Photon Emission,Emission-Computed Tomography, Single-Photon,Radionuclide Tomography, Single Photon Emission Computed,Single Photon Emission CT Scan,Single Photon Emission Computed Tomography,Single Photon Emission Computer Assisted Tomography,Single Photon Emission Computerized Tomography,Tomography, Single-Photon Emission-Computed
D016277 Ventricular Function, Left The hemodynamic and electrophysiological action of the left HEART VENTRICLE. Its measurement is an important aspect of the clinical evaluation of patients with heart disease to determine the effects of the disease on cardiac performance. Left Ventricular Function,Function, Left Ventricular,Functions, Left Ventricular,Left Ventricular Functions,Ventricular Functions, Left

Related Publications

R O Bonow, and V Dilsizian
July 1994, American journal of cardiac imaging,
R O Bonow, and V Dilsizian
February 1994, Annals of nuclear medicine,
R O Bonow, and V Dilsizian
January 1992, Journal of nuclear biology and medicine (Turin, Italy : 1991),
R O Bonow, and V Dilsizian
August 1994, Kaku igaku. The Japanese journal of nuclear medicine,
R O Bonow, and V Dilsizian
January 1994, JPMA. The Journal of the Pakistan Medical Association,
R O Bonow, and V Dilsizian
December 1991, Kaku igaku. The Japanese journal of nuclear medicine,
R O Bonow, and V Dilsizian
March 1998, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
Copied contents to your clipboard!