Evaluation of a lithium formate EPR dosimetry system for dose measurements around 192Ir brachytherapy sources. 2009

Laura Antonovic, and Håkan Gustafsson, and Gudrun Alm Carlsson, and Asa Carlsson Tedgren
Department of Medical and Health Sciences, Radiation Physics, Faculty of Health Sciences, Linköping University, SE-581 85 Linköping, Sweden.

A dosimetry system using lithium formate monohydrate (HCO2Li x H2O) as detector material and electron paramagnetic resonance (EPR) spectroscopy for readout has been used to measure absorbed dose distributions around clinical 192Ir sources. Cylindrical tablets with diameter of 4.5 mm, height of 4.8 mm, and density of 1.26 g/cm3 were manufactured. Homogeneity test and calibration of the dosimeters were performed in a 6 MV photon beam. 192Ir irradiations were performed in a PMMA phantom using two different source models, the GammaMed Plus HDR and the microSelectron PDR-v1 model. Measured absorbed doses to water in the PMMA phantom were converted to the corresponding absorbed doses to water in water phantoms of dimensions used by the treatment planning systems (TPSs) using correction factors explicitly derived for this experiment. Experimentally determined absorbed doses agreed with the absorbed doses to water calculated by the TPS to within +/-2.9%. Relative standard uncertainties in the experimentally determined absorbed doses were estimated to be within the range of 1.7%-1.3% depending on the radial distance from the source, the type of source (HDR or PDR), and the particular absorbed doses used. This work shows that a lithium formate dosimetry system is well suited for measurements of absorbed dose to water around clinical HDR and PDR 192Ir sources. Being less energy dependent than the commonly used thermoluminescent lithium fluoride (LiF) dosimeters, lithium formate monohydrate dosimeters are well suited to measure absorbed doses in situations where the energy dependence cannot easily be accounted for such as in multiple-source irradiations to verify treatment plans. Their wide dynamic range and linear dose response over the dose interval of 0.2-1000 Gy make them suitable for measurements on sources of the strengths used in clinical applications. The dosimeter size needs, however, to be reduced for application to single-source dosimetry.

UI MeSH Term Description Entries
D007496 Iridium Radioisotopes Unstable isotopes of iridium that decay or disintegrate emitting radiation. Ir atoms with atomic weights 182-190, 192, and 194-198 are radioactive iridium isotopes. Radioisotopes, Iridium
D011874 Radiometry The measurement of radiation by photography, as in x-ray film and film badge, by Geiger-Mueller tube, and by SCINTILLATION COUNTING. Geiger-Mueller Counters,Nuclear Track Detection,Radiation Dosimetry,Dosimetry, Radiation,Geiger Counter,Geiger-Mueller Counter Tube,Geiger-Mueller Probe,Geiger-Mueller Tube,Radiation Counter,Counter Tube, Geiger-Mueller,Counter Tubes, Geiger-Mueller,Counter, Geiger,Counter, Radiation,Counters, Geiger,Counters, Geiger-Mueller,Counters, Radiation,Detection, Nuclear Track,Dosimetries, Radiation,Geiger Counters,Geiger Mueller Counter Tube,Geiger Mueller Counters,Geiger Mueller Probe,Geiger Mueller Tube,Geiger-Mueller Counter Tubes,Geiger-Mueller Probes,Geiger-Mueller Tubes,Probe, Geiger-Mueller,Probes, Geiger-Mueller,Radiation Counters,Radiation Dosimetries,Tube, Geiger-Mueller,Tube, Geiger-Mueller Counter,Tubes, Geiger-Mueller,Tubes, Geiger-Mueller Counter
D011879 Radiotherapy Dosage The total amount of radiation absorbed by tissues as a result of radiotherapy. Dosage, Radiotherapy,Dosages, Radiotherapy,Radiotherapy Dosages
D001918 Brachytherapy A collective term for interstitial, intracavity, and surface radiotherapy. It uses small sealed or partly-sealed sources that may be placed on or near the body surface or within a natural body cavity or implanted directly into the tissues. Curietherapy,Implant Radiotherapy,Plaque Therapy, Radioisotope,Radioisotope Brachytherapy,Radiotherapy, Interstitial,Radiotherapy, Intracavity,Radiotherapy, Surface,Brachytherapy, Radioisotope,Interstitial Radiotherapy,Intracavity Radiotherapy,Radioisotope Plaque Therapy,Radiotherapy, Implant,Surface Radiotherapy,Therapy, Radioisotope Plaque
D004578 Electron Spin Resonance Spectroscopy A technique applicable to the wide variety of substances which exhibit paramagnetism because of the magnetic moments of unpaired electrons. The spectra are useful for detection and identification, for determination of electron structure, for study of interactions between molecules, and for measurement of nuclear spins and moments. (From McGraw-Hill Encyclopedia of Science and Technology, 7th edition) Electron nuclear double resonance (ENDOR) spectroscopy is a variant of the technique which can give enhanced resolution. Electron spin resonance analysis can now be used in vivo, including imaging applications such as MAGNETIC RESONANCE IMAGING. ENDOR,Electron Nuclear Double Resonance,Electron Paramagnetic Resonance,Paramagnetic Resonance,Electron Spin Resonance,Paramagnetic Resonance, Electron,Resonance, Electron Paramagnetic,Resonance, Electron Spin,Resonance, Paramagnetic
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D005561 Formates Derivatives of formic acids. Included under this heading are a broad variety of acid forms, salts, esters, and amides that are formed with a single carbon carboxy group. Formic Acids,Acids, Formic
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face
D017076 Computer-Aided Design The use of computers for designing and/or manufacturing of anything, including drugs, surgical procedures, orthotics, and prosthetics. CAD-CAM,Computer-Aided Manufacturing,Computer-Assisted Design,Computer-Assisted Manufacturing,Computer Aided Design,Computer Aided Manufacturing,Computer Assisted Design,Computer Assisted Manufacturing,Computer-Aided Designs,Computer-Assisted Designs,Design, Computer-Aided,Design, Computer-Assisted,Designs, Computer-Aided,Designs, Computer-Assisted,Manufacturing, Computer-Aided,Manufacturing, Computer-Assisted

Related Publications

Laura Antonovic, and Håkan Gustafsson, and Gudrun Alm Carlsson, and Asa Carlsson Tedgren
February 2001, Physics in medicine and biology,
Laura Antonovic, and Håkan Gustafsson, and Gudrun Alm Carlsson, and Asa Carlsson Tedgren
December 2019, Radiation protection dosimetry,
Laura Antonovic, and Håkan Gustafsson, and Gudrun Alm Carlsson, and Asa Carlsson Tedgren
February 2000, Physics in medicine and biology,
Laura Antonovic, and Håkan Gustafsson, and Gudrun Alm Carlsson, and Asa Carlsson Tedgren
December 2002, Physics in medicine and biology,
Laura Antonovic, and Håkan Gustafsson, and Gudrun Alm Carlsson, and Asa Carlsson Tedgren
May 2015, Physics in medicine and biology,
Laura Antonovic, and Håkan Gustafsson, and Gudrun Alm Carlsson, and Asa Carlsson Tedgren
September 2010, Medical physics,
Laura Antonovic, and Håkan Gustafsson, and Gudrun Alm Carlsson, and Asa Carlsson Tedgren
January 2014, Medical dosimetry : official journal of the American Association of Medical Dosimetrists,
Laura Antonovic, and Håkan Gustafsson, and Gudrun Alm Carlsson, and Asa Carlsson Tedgren
April 2010, Physics in medicine and biology,
Laura Antonovic, and Håkan Gustafsson, and Gudrun Alm Carlsson, and Asa Carlsson Tedgren
September 2008, Physics in medicine and biology,
Laura Antonovic, and Håkan Gustafsson, and Gudrun Alm Carlsson, and Asa Carlsson Tedgren
November 2008, Medical physics,