Real-time gait event detection using wearable sensors. 2009

Michael Hanlon, and Ross Anderson
Sport and Exercise Sciences Research Institute, University of Ulster, School of Sports Studies, Jordanstown, Co. Antrim, Northern Ireland. M.hanlon@ulster.ac.uk

Real-time gait event detection is a requirement for functional electrical stimulation and gait biofeedback. This gait event detection should ideally be achieved using an ambulatory system of durable, lightweight, low-cost sensors. Previous research has reported issues with durability in footswitch systems. Therefore, this study describes the development and assessment of novel detection algorithms using footswitch and accelerometer sensors on 12 healthy individuals. Subjects were equipped with one force sensitive resistor on the heel, one accelerometer at the foot, and one accelerometer at the knee. Subjects performed 10, 8-m walking trials in each of three conditions: normal, slow, and altered (reduced knee ROM) walking. Data from a subset of four subjects were used to develop prediction algorithms for initial contact (IC). Subsequently, these algorithms were tested on the remaining eight subjects against standard forceplate IC data (threshold of 5 N on a rising edge). The footswitch force threshold algorithm was most accurate for IC detection (mean absolute error of 2.4+/-2.1 ms) and was significantly more accurate (p<0.001) than the optimal accelerometer algorithm (mean absolute error of 9.5+/-9.0 ms). The optimal accelerometer algorithm used data from both accelerometers, with IC determined from the second derivative of foot fore-aft acceleration. The error results for footswitch and accelerometer algorithms are lower (approximately 60%) than in previous research on ambulatory real-time gait event detection systems. Currently, footswitch systems must be recommended over accelerometer systems for accurate detection of IC, however, further research into accelerometer algorithms is merited due to its advantages as a durable, low-cost sensor.

UI MeSH Term Description Entries
D008297 Male Males
D008991 Monitoring, Physiologic The continuous measurement of physiological processes, blood pressure, heart rate, renal output, reflexes, respiration, etc., in a patient or experimental animal; includes pharmacologic monitoring, the measurement of administered drugs or their metabolites in the blood, tissues, or urine. Patient Monitoring,Monitoring, Physiological,Physiologic Monitoring,Monitoring, Patient,Physiological Monitoring
D009989 Orthotic Devices Apparatus used to support, align, or augment the functioning of parts of the body. Orthoses,Orthosis,Parapodium,Device, Orthotic,Devices, Orthotic,Orthose,Orthotic Device,Parapodiums
D004558 Electric Stimulation Use of electric potential or currents to elicit biological responses. Stimulation, Electric,Electrical Stimulation,Electric Stimulations,Electrical Stimulations,Stimulation, Electrical,Stimulations, Electric,Stimulations, Electrical
D005260 Female Females
D005684 Gait Manner or style of walking. Gaits
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000054 Acceleration An increase in the rate of speed. Accelerations
D000465 Algorithms A procedure consisting of a sequence of algebraic formulas and/or logical steps to calculate or determine a given task. Algorithm
D001676 Biofeedback, Psychology The therapy technique of providing the status of one's own AUTONOMIC NERVOUS SYSTEM function (e.g., skin temperature, heartbeats, brain waves) as visual or auditory feedback in order to self-control related conditions (e.g., hypertension, migraine headaches). Biofeedback (Psychology),Bogus Physiological Feedback,False Physiological Feedback,Feedback, Psychophysiologic,Biofeedback,Feedback, Psychophysiological,Myofeedback,Psychophysiologic Feedback,Biofeedbacks,Biofeedbacks (Psychology),Biofeedbacks, Psychology,Bogus Physiological Feedbacks,False Physiological Feedbacks,Feedback, Bogus Physiological,Feedback, False Physiological,Feedbacks, Bogus Physiological,Feedbacks, False Physiological,Myofeedbacks,Physiological Feedback, Bogus,Physiological Feedback, False,Physiological Feedbacks, Bogus,Physiological Feedbacks, False,Psychology Biofeedback,Psychology Biofeedbacks

Related Publications

Michael Hanlon, and Ross Anderson
August 2016, Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference,
Michael Hanlon, and Ross Anderson
June 2022, Sensors (Basel, Switzerland),
Michael Hanlon, and Ross Anderson
February 2021, Sensors (Basel, Switzerland),
Michael Hanlon, and Ross Anderson
June 2011, Medical & biological engineering & computing,
Michael Hanlon, and Ross Anderson
January 2012, Sensors (Basel, Switzerland),
Michael Hanlon, and Ross Anderson
December 2022, IEEE journal of biomedical and health informatics,
Michael Hanlon, and Ross Anderson
December 2013, Medical engineering & physics,
Michael Hanlon, and Ross Anderson
January 2019, PloS one,
Michael Hanlon, and Ross Anderson
November 2009, IEEE transactions on information technology in biomedicine : a publication of the IEEE Engineering in Medicine and Biology Society,
Michael Hanlon, and Ross Anderson
April 2021, Sensors (Basel, Switzerland),
Copied contents to your clipboard!