A randomized double-blind crossover comparison of four rate-responsive pacing modes. 1991

N Sulke, and J Chambers, and A Dritsas, and E Sowton
Department of Cardiology, Guy's Hospital, London, England.

The aim of this study was to compare, both subjectively and objectively, four modern rate-responsive pacing modes in a double-blind crossover design. Twenty-two patients, aged 18 to 81 years, had an activity-sensing dual chamber universal rate-responsive (DDDR) pacemaker implanted for treatment of high grade atrioventricular block and chronotropic incompetence. They were randomly programmed to VVIR (ventricular demand rate-responsive), DDIR (dual chamber demand rate-responsive), DDD (dual chamber universal) or DDDR (dual chamber universal rate-responsive) mode and assessed after 4 weeks of out-of-hospital activity. Five patients, all with VVIR pacing, requested early reprogramming. The DDDR mode was preferred by 59% of patients; the VVIR mode was the least acceptable mode in 73%. Perceived "general well-being," exercise capacity, functional status and symptoms were significantly worse in the VVIR than in dual rate-responsive modes. Exercise treadmill time was longer in DDDR mode (p less than 0.01), but similar in all other modes. During standardized daily activities, heart rate in VVIR and DDIR modes underresponded to mental stress. All rate-augmented modes overresponded to staircase descent, whereas the DDD mode significantly underresponded to staircase ascent. Echocardiography revealed no difference in chamber dimensions, left ventricular fractional shortening or pulmonary artery pressure in any mode. Cardiac output was greater at rest in the dual modes than in the VVIR mode (p = 0.006) but was similar at 120 beats/min. Beat to beat variability of cardiac output was greatest in VVIR mode (p less than 0.0001), with DDIR showing greater variability than DDD or DDDR modes (p less than 0.05). Mitral regurgitation estimated by Doppler color flow imaging was similar in all modes, but tricuspid regurgitation was significantly greater in VVIR than in dual modes (p less than 0.03). Subjects who preferred the DDDR mode and those who found the VVIR mode least acceptable had significantly greater increases in stroke volume when paced in the DDD mode than in the ventricular-inhibited (VVI) mode at rest (22%) when compared with subjects who preferred other modes (2%, p = 0.03). No other objective variable was predictive of subjective benefit from any rate-responsive pacing mode. Thus, dual sensor rate-responsive pacing (DDDR) is superior objectively and subjectively to single sensor (VVIR, DDIR and DDD) pacing and subjective benefit from dual chamber rate-augmented pacing is predictable echocardiographically.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D011187 Posture The position or physical attitude of the body. Postures
D011446 Prospective Studies Observation of a population for a sufficient number of persons over a sufficient number of years to generate incidence or mortality rates subsequent to the selection of the study group. Prospective Study,Studies, Prospective,Study, Prospective
D011795 Surveys and Questionnaires Collections of data obtained from voluntary subjects. The information usually takes the form of answers to questions, or suggestions. Community Survey,Nonrespondent,Questionnaire,Questionnaires,Respondent,Survey,Survey Method,Survey Methods,Surveys,Baseline Survey,Community Surveys,Methodology, Survey,Nonrespondents,Questionnaire Design,Randomized Response Technique,Repeated Rounds of Survey,Respondents,Survey Methodology,Baseline Surveys,Design, Questionnaire,Designs, Questionnaire,Methods, Survey,Questionnaire Designs,Questionnaires and Surveys,Randomized Response Techniques,Response Technique, Randomized,Response Techniques, Randomized,Survey, Baseline,Survey, Community,Surveys, Baseline,Surveys, Community,Techniques, Randomized Response
D002302 Cardiac Output The volume of BLOOD passing through the HEART per unit of time. It is usually expressed as liters (volume) per minute so as not to be confused with STROKE VOLUME (volume per beat). Cardiac Outputs,Output, Cardiac,Outputs, Cardiac
D002304 Cardiac Pacing, Artificial Regulation of the rate of contraction of the heart muscles by an artificial pacemaker. Pacing, Cardiac, Artificial,Artificial Cardiac Pacing,Artificial Cardiac Pacings,Cardiac Pacings, Artificial,Pacing, Artificial Cardiac,Pacings, Artificial Cardiac
D004311 Double-Blind Method A method of studying a drug or procedure in which both the subjects and investigators are kept unaware of who is actually getting which specific treatment. Double-Masked Study,Double-Blind Study,Double-Masked Method,Double Blind Method,Double Blind Study,Double Masked Method,Double Masked Study,Double-Blind Methods,Double-Blind Studies,Double-Masked Methods,Double-Masked Studies,Method, Double-Blind,Method, Double-Masked,Methods, Double-Blind,Methods, Double-Masked,Studies, Double-Blind,Studies, Double-Masked,Study, Double-Blind,Study, Double-Masked
D005080 Exercise Test Controlled physical activity which is performed in order to allow assessment of physiological functions, particularly cardiovascular and pulmonary, but also aerobic capacity. Maximal (most intense) exercise is usually required but submaximal exercise is also used. Arm Ergometry Test,Bicycle Ergometry Test,Cardiopulmonary Exercise Testing,Exercise Testing,Step Test,Stress Test,Treadmill Test,Cardiopulmonary Exercise Test,EuroFit Tests,Eurofit Test Battery,European Fitness Testing Battery,Fitness Testing,Physical Fitness Testing,Arm Ergometry Tests,Bicycle Ergometry Tests,Cardiopulmonary Exercise Tests,Ergometry Test, Arm,Ergometry Test, Bicycle,Ergometry Tests, Arm,Ergometry Tests, Bicycle,EuroFit Test,Eurofit Test Batteries,Exercise Test, Cardiopulmonary,Exercise Testing, Cardiopulmonary,Exercise Tests,Exercise Tests, Cardiopulmonary,Fitness Testing, Physical,Fitness Testings,Step Tests,Stress Tests,Test Battery, Eurofit,Test, Arm Ergometry,Test, Bicycle Ergometry,Test, Cardiopulmonary Exercise,Test, EuroFit,Test, Exercise,Test, Step,Test, Stress,Test, Treadmill,Testing, Cardiopulmonary Exercise,Testing, Exercise,Testing, Fitness,Testing, Physical Fitness,Tests, Arm Ergometry,Tests, Bicycle Ergometry,Tests, Cardiopulmonary Exercise,Tests, EuroFit,Tests, Exercise,Tests, Step,Tests, Stress,Tests, Treadmill,Treadmill Tests
D005082 Physical Exertion Expenditure of energy during PHYSICAL ACTIVITY. Intensity of exertion may be measured by rate of OXYGEN CONSUMPTION; HEAT produced, or HEART RATE. Perceived exertion, a psychological measure of exertion, is included. Physical Effort,Effort, Physical,Efforts, Physical,Exertion, Physical,Exertions, Physical,Physical Efforts,Physical Exertions

Related Publications

N Sulke, and J Chambers, and A Dritsas, and E Sowton
February 1997, Journal of the American College of Cardiology,
N Sulke, and J Chambers, and A Dritsas, and E Sowton
September 1989, Clinical cardiology,
N Sulke, and J Chambers, and A Dritsas, and E Sowton
July 1987, Pacing and clinical electrophysiology : PACE,
N Sulke, and J Chambers, and A Dritsas, and E Sowton
May 2012, European journal of heart failure,
N Sulke, and J Chambers, and A Dritsas, and E Sowton
December 2016, Nitric oxide : biology and chemistry,
N Sulke, and J Chambers, and A Dritsas, and E Sowton
February 1979, Journal of the American Dental Association (1939),
N Sulke, and J Chambers, and A Dritsas, and E Sowton
November 2001, Pacing and clinical electrophysiology : PACE,
N Sulke, and J Chambers, and A Dritsas, and E Sowton
December 1987, British heart journal,
N Sulke, and J Chambers, and A Dritsas, and E Sowton
March 2001, Archives des maladies du coeur et des vaisseaux,
Copied contents to your clipboard!