Exercise echocardiography and technetium-99m MIBI single-photon emission computed tomography in the detection of coronary artery disease. 1991

M M Pozzoli, and P M Fioretti, and A Salustri, and A E Reijs, and J R Roelandt
Department of Cardiology, Dijkzigt University Hospital, Rotterdam, The Netherlands.

To compare the relative diagnostic value of exercise echocardiography with perfusion technetium-99m metoxyisobutylisonitrile single-photon emission computed tomography (SPECT) in detecting coronary artery disease (CAD), 75 patients with suspected CAD but a normal electrocardiogram (ECG) at rest were included in a prospective correlative study. Both the exercise echocardiograms and SPECT studies were performed in conjunction with the same symptom-limited bicycle exercise test. The development of either a new wall motion abnormality or a reversible perfusion defect after exercise, or both, were regarded as a positive test for the exercise echocardiographic and SPECT studies, respectively. The results of these 2 diagnostic tests were compared with coronary arteriography. Exercise echocardiography identified 35 (71%) and SPECT 41 (84%, p = 0.13) of the 49 patients with significant CAD (defined as greater than 50% diameter stenosis). Twenty-five of the 26 patients (96%) without significant coronary stenosis had negative exercise echocardiographic results and 23 of 26 (88%) had negative SPECT results. Exercise-induced new wall motion abnormalities showed a good correlation with reversible perfusion defects, and the results of the 2 methods were concordant in 65 of 75 patients (agreement = 88%, kappa = 0.75 +/- 0.14). Both the diagnostic accuracy of exercise echocardiography and SPECT were significantly higher than the exercise ECG (81 vs 64%, p less than 0.02 and 88 vs 64%, p less than 0.005). The sensitivity and specificity for detecting individual diseased vessels were 60 and 95% for exercise echocardiography and 67 and 94% for SPECT.(ABSTRACT TRUNCATED AT 250 WORDS)

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D009570 Nitriles Organic compounds containing the -CN radical. The concept is distinguished from CYANIDES, which denotes inorganic salts of HYDROGEN CYANIDE. Nitrile
D011446 Prospective Studies Observation of a population for a sufficient number of persons over a sufficient number of years to generate incidence or mortality rates subsequent to the selection of the study group. Prospective Study,Studies, Prospective,Study, Prospective
D003287 Contrast Media Substances used to allow enhanced visualization of tissues. Radiopaque Media,Contrast Agent,Contrast Agents,Contrast Material,Contrast Materials,Radiocontrast Agent,Radiocontrast Agents,Radiocontrast Media,Agent, Contrast,Agent, Radiocontrast,Agents, Contrast,Agents, Radiocontrast,Material, Contrast,Materials, Contrast,Media, Contrast,Media, Radiocontrast,Media, Radiopaque
D003327 Coronary Disease An imbalance between myocardial functional requirements and the capacity of the CORONARY VESSELS to supply sufficient blood flow. It is a form of MYOCARDIAL ISCHEMIA (insufficient blood supply to the heart muscle) caused by a decreased capacity of the coronary vessels. Coronary Heart Disease,Coronary Diseases,Coronary Heart Diseases,Disease, Coronary,Disease, Coronary Heart,Diseases, Coronary,Diseases, Coronary Heart,Heart Disease, Coronary,Heart Diseases, Coronary
D004452 Echocardiography Ultrasonic recording of the size, motion, and composition of the heart and surrounding tissues. The standard approach is transthoracic. Echocardiography, Contrast,Echocardiography, Cross-Sectional,Echocardiography, M-Mode,Echocardiography, Transthoracic,Echocardiography, Two-Dimensional,Transthoracic Echocardiography,2-D Echocardiography,2D Echocardiography,Contrast Echocardiography,Cross-Sectional Echocardiography,Echocardiography, 2-D,Echocardiography, 2D,M-Mode Echocardiography,Two-Dimensional Echocardiography,2 D Echocardiography,Cross Sectional Echocardiography,Echocardiography, 2 D,Echocardiography, Cross Sectional,Echocardiography, M Mode,Echocardiography, Two Dimensional,M Mode Echocardiography,Two Dimensional Echocardiography
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D005080 Exercise Test Controlled physical activity which is performed in order to allow assessment of physiological functions, particularly cardiovascular and pulmonary, but also aerobic capacity. Maximal (most intense) exercise is usually required but submaximal exercise is also used. Arm Ergometry Test,Bicycle Ergometry Test,Cardiopulmonary Exercise Testing,Exercise Testing,Step Test,Stress Test,Treadmill Test,Cardiopulmonary Exercise Test,EuroFit Tests,Eurofit Test Battery,European Fitness Testing Battery,Fitness Testing,Physical Fitness Testing,Arm Ergometry Tests,Bicycle Ergometry Tests,Cardiopulmonary Exercise Tests,Ergometry Test, Arm,Ergometry Test, Bicycle,Ergometry Tests, Arm,Ergometry Tests, Bicycle,EuroFit Test,Eurofit Test Batteries,Exercise Test, Cardiopulmonary,Exercise Testing, Cardiopulmonary,Exercise Tests,Exercise Tests, Cardiopulmonary,Fitness Testing, Physical,Fitness Testings,Step Tests,Stress Tests,Test Battery, Eurofit,Test, Arm Ergometry,Test, Bicycle Ergometry,Test, Cardiopulmonary Exercise,Test, EuroFit,Test, Exercise,Test, Step,Test, Stress,Test, Treadmill,Testing, Cardiopulmonary Exercise,Testing, Exercise,Testing, Fitness,Testing, Physical Fitness,Tests, Arm Ergometry,Tests, Bicycle Ergometry,Tests, Cardiopulmonary Exercise,Tests, EuroFit,Tests, Exercise,Tests, Step,Tests, Stress,Tests, Treadmill,Treadmill Tests
D005260 Female Females

Related Publications

M M Pozzoli, and P M Fioretti, and A Salustri, and A E Reijs, and J R Roelandt
June 1993, Journal of the American College of Cardiology,
M M Pozzoli, and P M Fioretti, and A Salustri, and A E Reijs, and J R Roelandt
January 1996, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology,
M M Pozzoli, and P M Fioretti, and A Salustri, and A E Reijs, and J R Roelandt
January 1998, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology,
M M Pozzoli, and P M Fioretti, and A Salustri, and A E Reijs, and J R Roelandt
March 1998, The American journal of cardiology,
M M Pozzoli, and P M Fioretti, and A Salustri, and A E Reijs, and J R Roelandt
June 2019, Diagnostics (Basel, Switzerland),
M M Pozzoli, and P M Fioretti, and A Salustri, and A E Reijs, and J R Roelandt
September 1997, Clinical cardiology,
M M Pozzoli, and P M Fioretti, and A Salustri, and A E Reijs, and J R Roelandt
July 1997, Kaku igaku. The Japanese journal of nuclear medicine,
M M Pozzoli, and P M Fioretti, and A Salustri, and A E Reijs, and J R Roelandt
June 2019, Nuclear medicine and molecular imaging,
Copied contents to your clipboard!