Transmission diffraction-tomography system using a high-energy X-ray tube. 2010

D J Garrity, and P M Jenneson, and R Crook, and S M Vincent
Department of Physics, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford, Surrey, UK. DJ_Garrity@physics.org

A high-energy bench-top energy dispersive X-ray diffraction (EDXRD) system for 3-dimensional mapping of the crystalline structure and phase transformations in steel is described, for which preliminary data and system development are presented here. The use of precision tungsten slit screens with up to 225 keV X-rays allows for diffraction through samples of 304 L austenitic stainless steel of thickness 3-10 mm, while sample positioning is carried out with a precision goniometer and translation stage system.

UI MeSH Term Description Entries
D003461 Crystallography The branch of science that deals with the geometric description of crystals and their internal arrangement. (McGraw-Hill Dictionary of Scientific and Technical Terms, 4th ed) Crystallographies
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity
D013232 Steel A tough, malleable, iron-based alloy containing up to, but no more than, two percent carbon and often other metals. It is used in medicine and dentistry in implants and instrumentation. Steels
D014056 Tomography, X-Ray Tomography using x-ray transmission. Tomography, Transmission,X-Ray Tomography,Zonography,Radiographic Tomography,Tomography, Radiographic,Tomography, X Ray,Tomography, Xray,Transmission Tomography,X Ray Tomography,Xray Tomography
D014965 X-Rays Penetrating electromagnetic radiation emitted when the inner orbital electrons of an atom are excited and release radiant energy. X-ray wavelengths range from 1 pm to 10 nm. Hard X-rays are the higher energy, shorter wavelength X-rays. Soft x-rays or Grenz rays are less energetic and longer in wavelength. The short wavelength end of the X-ray spectrum overlaps the GAMMA RAYS wavelength range. The distinction between gamma rays and X-rays is based on their radiation source. Grenz Ray,Grenz Rays,Roentgen Ray,Roentgen Rays,X Ray,X-Ray,Xray,Radiation, X,X-Radiation,Xrays,Ray, Grenz,Ray, Roentgen,Ray, X,Rays, Grenz,Rays, Roentgen,Rays, X,X Radiation,X Rays,X-Radiations
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face
D019544 Equipment Failure Analysis The evaluation of incidents involving the loss of function of a device. These evaluations are used for a variety of purposes such as to determine the failure rates, the causes of failures, costs of failures, and the reliability and maintainability of devices. Materials Failure Analysis,Prosthesis Failure Analysis,Analysis, Equipment Failure,Analysis, Materials Failure,Analysis, Prosthesis Failure,Analyses, Equipment Failure,Analyses, Materials Failure,Analyses, Prosthesis Failure,Equipment Failure Analyses,Failure Analyses, Equipment,Failure Analyses, Materials,Failure Analyses, Prosthesis,Failure Analysis, Equipment,Failure Analysis, Materials,Failure Analysis, Prosthesis,Materials Failure Analyses,Prosthesis Failure Analyses

Related Publications

D J Garrity, and P M Jenneson, and R Crook, and S M Vincent
March 2015, Optics express,
D J Garrity, and P M Jenneson, and R Crook, and S M Vincent
October 2010, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine,
D J Garrity, and P M Jenneson, and R Crook, and S M Vincent
August 2009, IEEE transactions on ultrasonics, ferroelectrics, and frequency control,
D J Garrity, and P M Jenneson, and R Crook, and S M Vincent
May 1998, Journal of synchrotron radiation,
D J Garrity, and P M Jenneson, and R Crook, and S M Vincent
May 2010, The journal of physical chemistry. B,
D J Garrity, and P M Jenneson, and R Crook, and S M Vincent
January 2019, Structural dynamics (Melville, N.Y.),
D J Garrity, and P M Jenneson, and R Crook, and S M Vincent
April 2023, Optics express,
D J Garrity, and P M Jenneson, and R Crook, and S M Vincent
August 1988, Applied optics,
D J Garrity, and P M Jenneson, and R Crook, and S M Vincent
July 2009, Journal of synchrotron radiation,
D J Garrity, and P M Jenneson, and R Crook, and S M Vincent
March 2022, Journal of pharmaceutical sciences,
Copied contents to your clipboard!