A low-noise low-power amplifier for implantable device for neural signal acquisition. 2009

Ming-Ze Li, and Kea-Tiong Tang
Department of Electrical Engineering, National Tsing Hua University, Hsinchu, Taiwan, R.O.C.

This paper presents a low-noise low-power amplifier for implantable device for neural signal acquisition. By operating MOS transistors in the subthreshold region, smaller low-frequency noise and lower power consumption can be achieved. A low power, low-noise common-drain buffer and a low-noise, high-linearity, low pass filter are used for high frequency noise filtering. Post-layout simulation shows the input referred noise of the system is 2.19microVrms from 10Hz to 10 KHz, power consumption is 55.8microW, and the NEF is 2.53. The amplifier was fabricated using a TSMC 0.18microm 1P6M CMOS process. Simulation results show that this low-noise, low-power amplifier is suitable for implantable device applications.

UI MeSH Term Description Entries
D009474 Neurons The basic cellular units of nervous tissue. Each neuron consists of a body, an axon, and dendrites. Their purpose is to receive, conduct, and transmit impulses in the NERVOUS SYSTEM. Nerve Cells,Cell, Nerve,Cells, Nerve,Nerve Cell,Neuron
D003198 Computer Simulation Computer-based representation of physical systems and phenomena such as chemical processes. Computational Modeling,Computational Modelling,Computer Models,In silico Modeling,In silico Models,In silico Simulation,Models, Computer,Computerized Models,Computer Model,Computer Simulations,Computerized Model,In silico Model,Model, Computer,Model, Computerized,Model, In silico,Modeling, Computational,Modeling, In silico,Modelling, Computational,Simulation, Computer,Simulation, In silico,Simulations, Computer
D003201 Computers Programmable electronic devices designed to accept data, perform prescribed mathematical and logical operations at high speed, and display the results of these operations. Calculators, Programmable,Computer Hardware,Computers, Digital,Hardware, Computer,Calculator, Programmable,Computer,Computer, Digital,Digital Computer,Digital Computers,Programmable Calculator,Programmable Calculators
D004567 Electrodes, Implanted Surgically placed electric conductors through which ELECTRIC STIMULATION is delivered to or electrical activity is recorded from a specific point inside the body. Implantable Electrodes,Implantable Stimulation Electrodes,Implanted Electrodes,Implanted Stimulation Electrodes,Electrode, Implantable,Electrode, Implantable Stimulation,Electrode, Implanted,Electrode, Implanted Stimulation,Electrodes, Implantable,Electrodes, Implantable Stimulation,Electrodes, Implanted Stimulation,Implantable Electrode,Implantable Stimulation Electrode,Implanted Electrode,Implanted Stimulation Electrode,Stimulation Electrode, Implantable,Stimulation Electrode, Implanted,Stimulation Electrodes, Implantable,Stimulation Electrodes, Implanted
D004582 Electronics, Medical The research and development of ELECTRICAL EQUIPMENT AND SUPPLIES for such medical applications as diagnosis, therapy, research, anesthesia control, cardiac control, and surgery. (From McGraw-Hill Dictionary of Scientific and Technical Terms, 6th ed) Medical Electronics
D004594 Electrophysiology The study of the generation and behavior of electrical charges in living organisms particularly the nervous system and the effects of electricity on living organisms.
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000200 Action Potentials Abrupt changes in the membrane potential that sweep along the CELL MEMBRANE of excitable cells in response to excitation stimuli. Spike Potentials,Nerve Impulses,Action Potential,Impulse, Nerve,Impulses, Nerve,Nerve Impulse,Potential, Action,Potential, Spike,Potentials, Action,Potentials, Spike,Spike Potential
D000669 Amplifiers, Electronic Electronic devices that increase the magnitude of a signal's power level or current. Amplifier, Electronic,Electronic Amplifier,Electronic Amplifiers

Related Publications

Ming-Ze Li, and Kea-Tiong Tang
January 2008, Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference,
Ming-Ze Li, and Kea-Tiong Tang
April 2013, IEEE transactions on biomedical circuits and systems,
Ming-Ze Li, and Kea-Tiong Tang
June 2022, The Review of scientific instruments,
Ming-Ze Li, and Kea-Tiong Tang
January 2010, Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference,
Ming-Ze Li, and Kea-Tiong Tang
January 2014, Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference,
Ming-Ze Li, and Kea-Tiong Tang
January 2005, Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference,
Ming-Ze Li, and Kea-Tiong Tang
July 2020, Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference,
Ming-Ze Li, and Kea-Tiong Tang
May 1984, Medical & biological engineering & computing,
Ming-Ze Li, and Kea-Tiong Tang
September 2015, Sensors (Basel, Switzerland),
Ming-Ze Li, and Kea-Tiong Tang
January 2007, Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference,
Copied contents to your clipboard!