Failure of Hancock pericardial xenografts: is prophylactic bioprosthetic replacement justified? 1991

U Bortolotti, and A Milano, and F Guerra, and A Mazzucco, and E Mossuto, and G Thiene, and V Gallucci
Department of Cardiovascular Surgery, University of Padova Medical School, Italy.

The incidence of major valve-related complications was evaluated in a series of patients in whom the Hancock pericardial xenograft was used for aortic (AVR; n = 84), mitral (MVR; n = 17) and mitral-aortic (MAVR; n = 13) valve replacement. At 7 years actuarial survival is 66% +/- 8% after AVR, 64% +/- 13% after MVR, and 41% +/- 15% after MAVR, whereas actuarial freedom from valve-related death is 79% +/- 7% after AVR, 78% +/- 13% after MVR, and 81% +/- 12% after MAVR. Actuarial freedom from thromboemboli and anticoagulant-related hemorrhage at 7 years is 93% +/- 4% and 98% +/- 2% after AVR and 83% +/- 10% and 88% +/- 11% after MVR; no such complications occurred after MAVR. Structural valve deterioration determined at reoperation, at autopsy, or by clinical investigation was observed in 34 patients with AVR (10.0 +/- 0.2%/patient-year), in 10 with MVR (10.6 +/- 3.3%/patient-year), and in 9 with MAVR (16.6 +/- 5.5%/patient-year). After AVR, 19 patients underwent reoperation and 2 died before reoperation; 4 patients with MVR underwent reoperation, and 7 patients with MAVR underwent reoperation and 1 died before reoperation. Seventy-eight percent of the current survivors (13 patients with AVR, 7 with MVR, and 1 with MAVR) have clinical evidence of valve failure. At 7 years actuarial freedom from structural deterioration of the Hancock pericardial xenograft is 25% +/- 7% after AVR, 29% +/- 14% after MVR, and 0% after MAVR.(ABSTRACT TRUNCATED AT 250 WORDS)

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D008943 Mitral Valve The valve between the left atrium and left ventricle of the heart. Bicuspid Valve,Bicuspid Valves,Mitral Valves,Valve, Bicuspid,Valve, Mitral,Valves, Bicuspid,Valves, Mitral
D011475 Prosthesis Failure Malfunction of implantation shunts, valves, etc., and prosthesis loosening, migration, and breaking. Prosthesis Loosening,Prosthesis Durability,Prosthesis Migration,Prosthesis Survival,Durabilities, Prosthesis,Durability, Prosthesis,Failure, Prosthesis,Failures, Prosthesis,Loosening, Prosthesis,Loosenings, Prosthesis,Migration, Prosthesis,Migrations, Prosthesis,Prosthesis Durabilities,Prosthesis Failures,Prosthesis Loosenings,Prosthesis Migrations,Prosthesis Survivals,Survival, Prosthesis,Survivals, Prosthesis
D012086 Reoperation A repeat operation for the same condition in the same patient due to disease progression or recurrence, or as followup to failed previous surgery. Revision, Joint,Revision, Surgical,Surgery, Repeat,Surgical Revision,Repeat Surgery,Revision Surgery,Joint Revision,Revision Surgeries,Surgery, Revision
D004696 Endocarditis Inflammation of the inner lining of the heart (ENDOCARDIUM), the continuous membrane lining the four chambers and HEART VALVES. It is often caused by microorganisms including bacteria, viruses, fungi, and rickettsiae. Left untreated, endocarditis can damage heart valves and become life-threatening. Infective Endocarditis,Endocarditides,Endocarditides, Infective,Endocarditis, Infective,Infective Endocarditides
D005260 Female Females
D005500 Follow-Up Studies Studies in which individuals or populations are followed to assess the outcome of exposures, procedures, or effects of a characteristic, e.g., occurrence of disease. Followup Studies,Follow Up Studies,Follow-Up Study,Followup Study,Studies, Follow-Up,Studies, Followup,Study, Follow-Up,Study, Followup
D006350 Heart Valve Prosthesis A device that substitutes for a heart valve. It may be composed of biological material (BIOPROSTHESIS) and/or synthetic material. Prosthesis, Heart Valve,Cardiac Valve Prosthesis,Cardiac Valve Prostheses,Heart Valve Prostheses,Prostheses, Cardiac Valve,Prostheses, Heart Valve,Prosthesis, Cardiac Valve,Valve Prostheses, Cardiac,Valve Prostheses, Heart,Valve Prosthesis, Cardiac,Valve Prosthesis, Heart
D006470 Hemorrhage Bleeding or escape of blood from a vessel. Bleeding,Hemorrhages

Related Publications

U Bortolotti, and A Milano, and F Guerra, and A Mazzucco, and E Mossuto, and G Thiene, and V Gallucci
September 1994, The Journal of heart valve disease,
U Bortolotti, and A Milano, and F Guerra, and A Mazzucco, and E Mossuto, and G Thiene, and V Gallucci
August 1991, The Journal of thoracic and cardiovascular surgery,
U Bortolotti, and A Milano, and F Guerra, and A Mazzucco, and E Mossuto, and G Thiene, and V Gallucci
September 1986, Japanese circulation journal,
U Bortolotti, and A Milano, and F Guerra, and A Mazzucco, and E Mossuto, and G Thiene, and V Gallucci
June 1999, The Journal of cardiovascular surgery,
U Bortolotti, and A Milano, and F Guerra, and A Mazzucco, and E Mossuto, and G Thiene, and V Gallucci
January 1977, Revue de chirurgie orthopedique et reparatrice de l'appareil moteur,
U Bortolotti, and A Milano, and F Guerra, and A Mazzucco, and E Mossuto, and G Thiene, and V Gallucci
September 2010, The Annals of thoracic surgery,
U Bortolotti, and A Milano, and F Guerra, and A Mazzucco, and E Mossuto, and G Thiene, and V Gallucci
January 1989, Archives des maladies du coeur et des vaisseaux,
U Bortolotti, and A Milano, and F Guerra, and A Mazzucco, and E Mossuto, and G Thiene, and V Gallucci
September 1988, Journal of cardiac surgery,
U Bortolotti, and A Milano, and F Guerra, and A Mazzucco, and E Mossuto, and G Thiene, and V Gallucci
October 2004, The Journal of cardiovascular surgery,
U Bortolotti, and A Milano, and F Guerra, and A Mazzucco, and E Mossuto, and G Thiene, and V Gallucci
May 1976, Nederlands tijdschrift voor geneeskunde,
Copied contents to your clipboard!