Alterations in left ventricular diastolic twist mechanics during acute human cardiac allograft rejection. 1991

K L Yun, and M A Niczyporuk, and G T Daughters, and N B Ingels, and E B Stinson, and E L Alderman, and D E Hansen, and D C Miller
Department of Cardiovascular Surgery, Stanford University School of Medicine, Calif.

BACKGROUND Contraction of obliquely oriented left ventricular (LV) fibers results in a twisting motion of the left ventricle. The purpose of this study was to assess the effects of acute human cardiac allograft rejection on LV twist pattern and the twist-volume relation. RESULTS Tantalum markers were implanted into the LV midwall in 15 transplant recipients to measure time-varying, three-dimensional chamber twist using computer-assisted analysis of biplane cinefluoroscopic images. Twist was defined as the mean longitudinal gradient of circumferential rotation about the LV long axis. When plotted against normalized percent ejection fraction (%EF), the resulting twist-normalized %EF relation could be divided into three phases. In systole, LV twist was linearly related to ejection of blood. In contrast, diastolic untwist was characterized by early rapid recoil with little change in LV volume, followed by more gradual untwisting when the bulk of diastolic filling occurred. During 10 acute rejection episodes in 10 patients, maximum twist, peak systolic twist rate, and the slope of the systolic twist-normalized %EF relation did not change. In contrast, the slope of the early (first 15% of filling) diastolic twist-normalized %EF relation (M(early-dia)) decreased significantly (-0.194 +/- 0.062 [prerejection] versus -0.103 +/- 0.054 rad/cm [rejection], p = 0.0003), resulting in a prolonged tau 1/2 (time required to untwist by 50% [20 +/- 5% versus 28 +/- 5% of diastole], p = 0.0003) and decrease in percent untwisting at 15% diastolic LV filling (62 +/- 11% versus 36 +/- 13%, p = 0.0003). Therefore, a greater proportion of LV untwisting occurred later in diastole during rejection, as reflected by an increase in the slope (M(mid-dia)) of the middle to late (from 15 to 90% filling) diastolic twist-normalized %EF relation (-0.018 +/- 0.009 versus -0.030 +/- 0.010 rad/cm, p = 0.0015). Peak rate of untwist was not affected. With resolution of rejection, M(early-dia) and percent untwist during early diastole returned to baseline levels (p = NS versus baseline). There was also a trend for M(mid-dia) to return toward prerejection values (p = NS versus baseline), but this change did not reach statistical significance compared with rejection values. CONCLUSIONS Acute cardiac allograft rejection is associated with altered diastolic twist mechanics in the absence of any demonstratable systolic abnormalities. During rejection, myocardial edema and other factors may result in intrinsic changes of the elastic properties of the myocardium, thereby leading to modification of recoil forces responsible for the early, rapid unwinding of the deformed ventricle.

UI MeSH Term Description Entries
D007091 Image Processing, Computer-Assisted A technique of inputting two-dimensional or three-dimensional images into a computer and then enhancing or analyzing the imagery into a form that is more useful to the human observer. Biomedical Image Processing,Computer-Assisted Image Processing,Digital Image Processing,Image Analysis, Computer-Assisted,Image Reconstruction,Medical Image Processing,Analysis, Computer-Assisted Image,Computer-Assisted Image Analysis,Computer Assisted Image Analysis,Computer Assisted Image Processing,Computer-Assisted Image Analyses,Image Analyses, Computer-Assisted,Image Analysis, Computer Assisted,Image Processing, Biomedical,Image Processing, Computer Assisted,Image Processing, Digital,Image Processing, Medical,Image Processings, Medical,Image Reconstructions,Medical Image Processings,Processing, Biomedical Image,Processing, Digital Image,Processing, Medical Image,Processings, Digital Image,Processings, Medical Image,Reconstruction, Image,Reconstructions, Image
D009200 Myocardial Contraction Contractile activity of the MYOCARDIUM. Heart Contractility,Inotropism, Cardiac,Cardiac Inotropism,Cardiac Inotropisms,Contractilities, Heart,Contractility, Heart,Contraction, Myocardial,Contractions, Myocardial,Heart Contractilities,Inotropisms, Cardiac,Myocardial Contractions
D002933 Cineradiography Motion picture study of successive images appearing on a fluoroscopic screen. Cinefluorography,Radiocinematography,Cinefluorographies,Cineradiographies,Radiocinematographies
D006084 Graft Rejection An immune response with both cellular and humoral components, directed against an allogeneic transplant, whose tissue antigens are not compatible with those of the recipient. Transplant Rejection,Rejection, Transplant,Transplantation Rejection,Graft Rejections,Rejection, Graft,Rejection, Transplantation,Rejections, Graft,Rejections, Transplant,Rejections, Transplantation,Transplant Rejections,Transplantation Rejections
D006321 Heart The hollow, muscular organ that maintains the circulation of the blood. Hearts
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000208 Acute Disease Disease having a short and relatively severe course. Acute Diseases,Disease, Acute,Diseases, Acute
D000328 Adult A person having attained full growth or maturity. Adults are of 19 through 44 years of age. For a person between 19 and 24 years of age, YOUNG ADULT is available. Adults
D012680 Sensitivity and Specificity Binary classification measures to assess test results. Sensitivity or recall rate is the proportion of true positives. Specificity is the probability of correctly determining the absence of a condition. (From Last, Dictionary of Epidemiology, 2d ed) Specificity,Sensitivity,Specificity and Sensitivity
D013635 Tantalum A rare metallic element, atomic number 73, atomic weight 180.948, symbol Ta. It is a noncorrosive and malleable metal that has been used for plates or disks to replace cranial defects, for wire sutures, and for making prosthetic devices. Tantalum-181,Tantalum 181

Related Publications

K L Yun, and M A Niczyporuk, and G T Daughters, and N B Ingels, and E B Stinson, and E L Alderman, and D E Hansen, and D C Miller
February 1990, Circulation,
K L Yun, and M A Niczyporuk, and G T Daughters, and N B Ingels, and E B Stinson, and E L Alderman, and D E Hansen, and D C Miller
March 1995, Journal of the American College of Cardiology,
K L Yun, and M A Niczyporuk, and G T Daughters, and N B Ingels, and E B Stinson, and E L Alderman, and D E Hansen, and D C Miller
November 1987, Circulation,
K L Yun, and M A Niczyporuk, and G T Daughters, and N B Ingels, and E B Stinson, and E L Alderman, and D E Hansen, and D C Miller
January 1994, Circulation,
K L Yun, and M A Niczyporuk, and G T Daughters, and N B Ingels, and E B Stinson, and E L Alderman, and D E Hansen, and D C Miller
January 1990, Catheterization and cardiovascular diagnosis,
K L Yun, and M A Niczyporuk, and G T Daughters, and N B Ingels, and E B Stinson, and E L Alderman, and D E Hansen, and D C Miller
November 2013, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography,
K L Yun, and M A Niczyporuk, and G T Daughters, and N B Ingels, and E B Stinson, and E L Alderman, and D E Hansen, and D C Miller
April 2019, Circulation. Cardiovascular imaging,
K L Yun, and M A Niczyporuk, and G T Daughters, and N B Ingels, and E B Stinson, and E L Alderman, and D E Hansen, and D C Miller
July 2016, American journal of physiology. Heart and circulatory physiology,
K L Yun, and M A Niczyporuk, and G T Daughters, and N B Ingels, and E B Stinson, and E L Alderman, and D E Hansen, and D C Miller
August 2017, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography,
K L Yun, and M A Niczyporuk, and G T Daughters, and N B Ingels, and E B Stinson, and E L Alderman, and D E Hansen, and D C Miller
January 2002, American journal of physiology. Heart and circulatory physiology,
Copied contents to your clipboard!