Skin reflectance pulse oximetry: in vivo measurements from the forearm and calf. 1991

Y Mendelson, and M J McGinn
Department of Biomedical Engineering, Worcester Polytechnic Institute, MA 01609.

This study describes the results from a series of human experiments demonstrating the ability to measure arterial hemoglobin oxygen saturation (SaO2) from the forearm and calf using a reflectance pulse oximeter sensor. A special optical reflectance sensor that includes a heating element was interfaced to a temperature controller and a commercial Data-scope ACCUSAT pulse oximeter that was adapted for this study to perform as a reflectance pulse oximeter. The reflectance pulse oximeter sensor was evaluated in a group of 10 healthy adult volunteers during steady-state hypoxia. Hypoxia was induced by gradually lowering the inspired fraction of oxygen in the breathing gas mixture from 100 to 12%. Simultaneous SaO2 measurements obtained from the forearm and calf with two identical reflectance pulse oximeters were compared with SaO2 values measured by a finger sensor that was interfaced to a standard Datascope ACCUSAT transmittance pulse oximeter. The equations for the best-fitted linear regression lines between the percent reflectance, SpO2(r), and transmittance, SpO2(t), values in the range between 73 and 100% were SpO2(r) = -7.06 + 1.09 SpO2(t) for the forearm (n = 91, r = 0.95) and SpO2(r) = 7.78 + 0.93 SpO2(t) for the calf (n = 93, r = 0.88). The regression analysis of the forearm data revealed a mean +/- SD error of 2.47 +/- 1.66% (SaO2 = 90-100%), 2.35 +/- 2.45% (SaO2 = 80-89%), and 2.42 +/- 1.20% (SaO2 = 70-79%). The corresponding regression analysis of the calf data revealed a mean +/- SD error of 3.36 +/- 3.06% (SaO2 = 90-100%), 3.45 +/- 4.12% (SaO2 = 80-89%), and 2.97 +/- 2.75% (SaO2 = 70-79%).(ABSTRACT TRUNCATED AT 250 WORDS)

UI MeSH Term Description Entries
D007866 Leg The inferior part of the lower extremity between the KNEE and the ANKLE. Legs
D008297 Male Males
D010092 Oximetry The determination of oxygen-hemoglobin saturation of blood either by withdrawing a sample and passing it through a classical photoelectric oximeter or by electrodes attached to some translucent part of the body like finger, earlobe, or skin fold. It includes non-invasive oxygen monitoring by pulse oximetry. Pulse Oximetry,Oximetry, Pulse,Oximetries,Oximetries, Pulse,Pulse Oximetries
D010100 Oxygen An element with atomic symbol O, atomic number 8, and atomic weight [15.99903; 15.99977]. It is the most abundant element on earth and essential for respiration. Dioxygen,Oxygen-16,Oxygen 16
D001785 Blood Gas Monitoring, Transcutaneous The noninvasive measurement or determination of the partial pressure (tension) of oxygen and/or carbon dioxide locally in the capillaries of a tissue by the application to the skin of a special set of electrodes. These electrodes contain photoelectric sensors capable of picking up the specific wavelengths of radiation emitted by oxygenated versus reduced hemoglobin. Carbon Dioxide Partial Pressure Determination, Transcutaneous,Cutaneous Oximetry,Oximetry, Transcutaneous,Oxygen Partial Pressure Determination, Transcutaneous,Transcutaneous Blood Gas Monitoring,Transcutaneous Capnometry,Transcutaneous Oximetry,PtcO2,TcPCO2,Capnometries, Transcutaneous,Capnometry, Transcutaneous,Cutaneous Oximetries,Oximetries, Cutaneous,Oximetries, Transcutaneous,Oximetry, Cutaneous,Transcutaneous Capnometries,Transcutaneous Oximetries
D005069 Evaluation Studies as Topic Works about studies that determine the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. Critique,Evaluation Indexes,Evaluation Methodology,Evaluation Report,Evaluation Research,Methodology, Evaluation,Pre-Post Tests,Qualitative Evaluation,Quantitative Evaluation,Theoretical Effectiveness,Use-Effectiveness,Critiques,Effectiveness, Theoretical,Evaluation Methodologies,Evaluation Reports,Evaluation, Qualitative,Evaluation, Quantitative,Evaluations, Qualitative,Evaluations, Quantitative,Indexes, Evaluation,Methodologies, Evaluation,Pre Post Tests,Pre-Post Test,Qualitative Evaluations,Quantitative Evaluations,Report, Evaluation,Reports, Evaluation,Research, Evaluation,Test, Pre-Post,Tests, Pre-Post,Use Effectiveness
D005542 Forearm Part of the upper extremity in humans and primates extending from the ELBOW to the WRIST. Antebrachium,Antebrachiums,Forearms
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000328 Adult A person having attained full growth or maturity. Adults are of 19 through 44 years of age. For a person between 19 and 24 years of age, YOUNG ADULT is available. Adults
D000860 Hypoxia Sub-optimal OXYGEN levels in the ambient air of living organisms. Anoxia,Oxygen Deficiency,Anoxemia,Deficiency, Oxygen,Hypoxemia,Deficiencies, Oxygen,Oxygen Deficiencies

Related Publications

Y Mendelson, and M J McGinn
August 1993, IEEE transactions on bio-medical engineering,
Y Mendelson, and M J McGinn
October 1988, IEEE transactions on bio-medical engineering,
Y Mendelson, and M J McGinn
January 1996, Advances in experimental medicine and biology,
Y Mendelson, and M J McGinn
August 1995, European journal of obstetrics, gynecology, and reproductive biology,
Y Mendelson, and M J McGinn
May 2011, Journal of biophotonics,
Y Mendelson, and M J McGinn
January 2002, Anesthesia and analgesia,
Y Mendelson, and M J McGinn
August 2004, Journal of clinical monitoring and computing,
Y Mendelson, and M J McGinn
March 1992, Pediatric research,
Y Mendelson, and M J McGinn
March 1995, Journal of clinical monitoring,