Atrial fibrillation detection by heart rate variability in Poincare plot. 2009

Jinho Park, and Sangwook Lee, and Moongu Jeon
Department of Information and Communications, Gwangju Institute of Science and Technology, 1 Oryong-dong, Buk-gu, Gwangju, Republic of Korea. jinho@gist.ac.kr

BACKGROUND Atrial fibrillation (AFib) is one of the prominent causes of stroke, and its risk increases with age. We need to detect AFib correctly as early as possible to avoid medical disaster because it is likely to proceed into a more serious form in short time. If we can make a portable AFib monitoring system, it will be helpful to many old people because we cannot predict when a patient will have a spasm of AFib. METHODS We analyzed heart beat variability from inter-beat intervals obtained by a wavelet-based detector. We made a Poincare plot using the inter-beat intervals. By analyzing the plot, we extracted three feature measures characterizing AFib and non-AFib: the number of clusters, mean stepping increment of inter-beat intervals, and dispersion of the points around a diagonal line in the plot. We divided distribution of the number of clusters into two and calculated mean value of the lower part by k-means clustering method. We classified data whose number of clusters is more than one and less than this mean value as non-AFib data. In the other case, we tried to discriminate AFib from non-AFib using support vector machine with the other feature measures: the mean stepping increment and dispersion of the points in the Poincare plot. RESULTS We found that Poincare plot from non-AFib data showed some pattern, while the plot from AFib data showed irregularly irregular shape. In case of non-AFib data, the definite pattern in the plot manifested itself with some limited number of clusters or closely packed one cluster. In case of AFib data, the number of clusters in the plot was one or too many. We evaluated the accuracy using leave-one-out cross-validation. Mean sensitivity and mean specificity were 91.4% and 92.9% respectively. CONCLUSIONS Because pulse beats of ventricles are less likely to be influenced by baseline wandering and noise, we used the inter-beat intervals to diagnose AFib. We visually displayed regularity of the inter-beat intervals by way of Poincare plot. We tried to design an automated algorithm which did not require any human intervention and any specific threshold, and could be installed in a portable AFib monitoring system.

UI MeSH Term Description Entries
D008991 Monitoring, Physiologic The continuous measurement of physiological processes, blood pressure, heart rate, renal output, reflexes, respiration, etc., in a patient or experimental animal; includes pharmacologic monitoring, the measurement of administered drugs or their metabolites in the blood, tissues, or urine. Patient Monitoring,Monitoring, Physiological,Physiologic Monitoring,Monitoring, Patient,Physiological Monitoring
D010363 Pattern Recognition, Automated In INFORMATION RETRIEVAL, machine-sensing or identification of visible patterns (shapes, forms, and configurations). (Harrod's Librarians' Glossary, 7th ed) Automated Pattern Recognition,Pattern Recognition System,Pattern Recognition Systems
D004562 Electrocardiography Recording of the moment-to-moment electromotive forces of the HEART as projected onto various sites on the body's surface, delineated as a scalar function of time. The recording is monitored by a tracing on slow moving chart paper or by observing it on a cardioscope, which is a CATHODE RAY TUBE DISPLAY. 12-Lead ECG,12-Lead EKG,12-Lead Electrocardiography,Cardiography,ECG,EKG,Electrocardiogram,Electrocardiograph,12 Lead ECG,12 Lead EKG,12 Lead Electrocardiography,12-Lead ECGs,12-Lead EKGs,12-Lead Electrocardiographies,Cardiographies,ECG, 12-Lead,EKG, 12-Lead,Electrocardiograms,Electrocardiographies, 12-Lead,Electrocardiographs,Electrocardiography, 12-Lead
D006329 Heart Conduction System An impulse-conducting system composed of modified cardiac muscle, having the power of spontaneous rhythmicity and conduction more highly developed than the rest of the heart. Conduction System, Heart,Conduction Systems, Heart,Heart Conduction Systems,System, Heart Conduction,Systems, Heart Conduction
D006334 Heart Function Tests Examinations used to diagnose and treat heart conditions. Cardiac Function Tests,Cardiac Function Test,Function Test, Cardiac,Function Test, Heart,Function Tests, Cardiac,Function Tests, Heart,Heart Function Test,Test, Cardiac Function,Test, Heart Function,Tests, Cardiac Function,Tests, Heart Function
D006339 Heart Rate The number of times the HEART VENTRICLES contract per unit of time, usually per minute. Cardiac Rate,Chronotropism, Cardiac,Heart Rate Control,Heartbeat,Pulse Rate,Cardiac Chronotropy,Cardiac Chronotropism,Cardiac Rates,Chronotropy, Cardiac,Control, Heart Rate,Heart Rates,Heartbeats,Pulse Rates,Rate Control, Heart,Rate, Cardiac,Rate, Heart,Rate, Pulse
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000465 Algorithms A procedure consisting of a sequence of algebraic formulas and/or logical steps to calculate or determine a given task. Algorithm
D001281 Atrial Fibrillation Abnormal cardiac rhythm that is characterized by rapid, uncoordinated firing of electrical impulses in the upper chambers of the heart (HEART ATRIA). In such case, blood cannot be effectively pumped into the lower chambers of the heart (HEART VENTRICLES). It is caused by abnormal impulse generation. Auricular Fibrillation,Familial Atrial Fibrillation,Paroxysmal Atrial Fibrillation,Persistent Atrial Fibrillation,Atrial Fibrillation, Familial,Atrial Fibrillation, Paroxysmal,Atrial Fibrillation, Persistent,Atrial Fibrillations,Atrial Fibrillations, Familial,Atrial Fibrillations, Paroxysmal,Atrial Fibrillations, Persistent,Auricular Fibrillations,Familial Atrial Fibrillations,Fibrillation, Atrial,Fibrillation, Auricular,Fibrillation, Familial Atrial,Fibrillation, Paroxysmal Atrial,Fibrillation, Persistent Atrial,Fibrillations, Atrial,Fibrillations, Auricular,Fibrillations, Familial Atrial,Fibrillations, Paroxysmal Atrial,Fibrillations, Persistent Atrial,Paroxysmal Atrial Fibrillations,Persistent Atrial Fibrillations
D001331 Automation Controlled operation of an apparatus, process, or system by mechanical or electronic devices that take the place of human organs of observation, effort, and decision. (From Webster's Collegiate Dictionary, 1993) Automations

Related Publications

Jinho Park, and Sangwook Lee, and Moongu Jeon
December 2000, Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi,
Jinho Park, and Sangwook Lee, and Moongu Jeon
July 2020, Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference,
Jinho Park, and Sangwook Lee, and Moongu Jeon
January 2013, Indian journal of physiology and pharmacology,
Jinho Park, and Sangwook Lee, and Moongu Jeon
January 2021, Journal of traditional and complementary medicine,
Jinho Park, and Sangwook Lee, and Moongu Jeon
June 2021, Zhongguo yi liao qi xie za zhi = Chinese journal of medical instrumentation,
Jinho Park, and Sangwook Lee, and Moongu Jeon
August 2016, Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference,
Jinho Park, and Sangwook Lee, and Moongu Jeon
August 1998, Journal of cardiovascular electrophysiology,
Jinho Park, and Sangwook Lee, and Moongu Jeon
March 2004, The American journal of cardiology,
Jinho Park, and Sangwook Lee, and Moongu Jeon
May 2002, Ceskoslovenska fysiologie,
Jinho Park, and Sangwook Lee, and Moongu Jeon
February 2001, Herz,
Copied contents to your clipboard!