Accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia. 2010

John R Feiner, and Philip E Bickler, and Paul D Mannheimer
Department of Anesthesia and Perioperative Care, University of California at San Francisco, 521 Parnassus Ave., San Francisco, CA 94143-0648, USA. feinerj@anesthesia.ucsf.edu

BACKGROUND Methemoglobin in the blood cannot be detected by conventional pulse oximetry, although it can bias the oximeter's estimate (Spo2) of the true arterial functional oxygen saturation (Sao2). A recently introduced "Pulse CO-Oximeter" (Masimo Rainbow SET(R) Radical-7 Pulse CO-Oximeter, Masimo Corp., Irvine, CA) is intended to additionally monitor noninvasively the fractional carboxyhemoglobin and methemoglobin content in blood. The purpose of our study was to determine whether hypoxia affects the new device's estimated methemoglobin reading accuracy, and whether the presence of methemoglobin impairs the ability of the Radical-7 and a conventional pulse oximeter (Nonin 9700, Nonin Medical Inc., Plymouth, MN) to detect decreases in Sao2. METHODS Eight and 6 healthy adults were included in 2 study groups, respectively, each fitted with multiple sensors and a radial arterial catheter for blood sampling. In the first group, IV administration of approximately 300 mg sodium nitrite increased subjects' methemoglobin level to a 7% to 8% target and hypoxia was induced to different levels of Sao2 (70%-100%) by varying fractional inspired oxygen. In the second group, 15% methemoglobin at room air and 80% Sao2 were targeted. Pulse CO-oximeter readings were compared with arterial blood values measured using a Radiometer multiwavelength hemoximeter. Pulse CO-oximeter methemoglobin reading performance was analyzed by observing the incidence of meaningful reading errors at the various hypoxia levels. This was used to determine the impact on predictive values for detecting methemoglobinemia. Spo2 reading bias, precision, and root mean square error were evaluated during conditions of elevated methemoglobin. RESULTS Observations spanned 66.2% to 99% Sao2 and 0.6% to 14.4% methemoglobin over the 2 groups (170 blood draws). Masimo methemoglobin reading bias and precision over the full Sao2 span was 7.7% +/- 13.0%. Best accuracy was found in the 95% to 100% Sao2 range (1.9% +/- 2.5%), progressing to its worst in the 70% to 80% range (24.8% +/- 15.6%). Occurrence of methemoglobin readings in error >5% increased over each 5-point decrease in Sao2 (P < 0.05). Masimo Spo2 readings were biased -6.3% +/- 3.0% in the 95% to 100% Sao2 range with 4% to 8.3% methemoglobin. Both the Radical-7 and Nonin 9700 pulse oximeters accurately detected decreases in Sao(2) <90% with 4% to 15% methemoglobin, despite displaying low Spo2 readings when Sao2 was >95%. CONCLUSIONS The Radical-7's methemoglobin readings become progressively more inaccurate as Sao2 decreases <95%, at times overestimating true values by 10% to 40%. Elevated methemoglobin causes the Spo2 readings to underestimate Sao2 similar to conventional 2-wavelength pulse oximeters at high saturation. Spo2 readings from both types of instruments continue to trend downward during the development of hypoxemia (Sao2 <90%) with methemoglobin levels up to 15%.

UI MeSH Term Description Entries
D008297 Male Males
D008706 Methemoglobin Ferrihemoglobin
D008708 Methemoglobinemia The presence of methemoglobin in the blood, resulting in cyanosis. A small amount of methemoglobin is present in the blood normally, but injury or toxic agents convert a larger proportion of hemoglobin into methemoglobin, which does not function reversibly as an oxygen carrier. Methemoglobinemia may be due to a defect in the enzyme NADH methemoglobin reductase (an autosomal recessive trait) or to an abnormality in hemoglobin M (an autosomal dominant trait). (Dorland, 27th ed) Methemoglobinemias
D010092 Oximetry The determination of oxygen-hemoglobin saturation of blood either by withdrawing a sample and passing it through a classical photoelectric oximeter or by electrodes attached to some translucent part of the body like finger, earlobe, or skin fold. It includes non-invasive oxygen monitoring by pulse oximetry. Pulse Oximetry,Oximetry, Pulse,Oximetries,Oximetries, Pulse,Pulse Oximetries
D010100 Oxygen An element with atomic symbol O, atomic number 8, and atomic weight [15.99903; 15.99977]. It is the most abundant element on earth and essential for respiration. Dioxygen,Oxygen-16,Oxygen 16
D011237 Predictive Value of Tests In screening and diagnostic tests, the probability that a person with a positive test is a true positive (i.e., has the disease), is referred to as the predictive value of a positive test; whereas, the predictive value of a negative test is the probability that the person with a negative test does not have the disease. Predictive value is related to the sensitivity and specificity of the test. Negative Predictive Value,Positive Predictive Value,Predictive Value Of Test,Predictive Values Of Tests,Negative Predictive Values,Positive Predictive Values,Predictive Value, Negative,Predictive Value, Positive
D001784 Blood Gas Analysis Measurement of oxygen and carbon dioxide in the blood. Analysis, Blood Gas,Analyses, Blood Gas,Blood Gas Analyses,Gas Analyses, Blood,Gas Analysis, Blood
D002248 Carbon Monoxide Carbon monoxide (CO). A poisonous colorless, odorless, tasteless gas. It combines with hemoglobin to form carboxyhemoglobin, which has no oxygen carrying capacity. The resultant oxygen deprivation causes headache, dizziness, decreased pulse and respiratory rates, unconsciousness, and death. (From Merck Index, 11th ed) Monoxide, Carbon
D002263 Carboxyhemoglobin Carbomonoxyhemoglobin,Carbonmonoxyhemoglobin,Carbonylhemoglobin,Carboxyhemoglobin A,Carboxyhemoglobin C
D003627 Data Interpretation, Statistical Application of statistical procedures to analyze specific observed or assumed facts from a particular study. Data Analysis, Statistical,Data Interpretations, Statistical,Interpretation, Statistical Data,Statistical Data Analysis,Statistical Data Interpretation,Analyses, Statistical Data,Analysis, Statistical Data,Data Analyses, Statistical,Interpretations, Statistical Data,Statistical Data Analyses,Statistical Data Interpretations

Related Publications

John R Feiner, and Philip E Bickler, and Paul D Mannheimer
January 1989, Gastrointestinal endoscopy,
John R Feiner, and Philip E Bickler, and Paul D Mannheimer
April 1994, Southern medical journal,
John R Feiner, and Philip E Bickler, and Paul D Mannheimer
January 2011, Hepato-gastroenterology,
John R Feiner, and Philip E Bickler, and Paul D Mannheimer
January 2014, Journal of intensive care medicine,
John R Feiner, and Philip E Bickler, and Paul D Mannheimer
October 1992, International journal of sports medicine,
John R Feiner, and Philip E Bickler, and Paul D Mannheimer
December 1992, Journal of cardiothoracic and vascular anesthesia,
John R Feiner, and Philip E Bickler, and Paul D Mannheimer
August 1994, Journal of post anesthesia nursing,
John R Feiner, and Philip E Bickler, and Paul D Mannheimer
May 2002, Acta obstetricia et gynecologica Scandinavica,
John R Feiner, and Philip E Bickler, and Paul D Mannheimer
January 1997, Dimensions of critical care nursing : DCCN,
John R Feiner, and Philip E Bickler, and Paul D Mannheimer
November 2006, Anesthesiology,
Copied contents to your clipboard!