The ion sensitive field effect transistor (ISFET) pH electrode: a new sensor for long term ambulatory pH monitoring. 1991

P Duroux, and C Emde, and P Bauerfeind, and C Francis, and A Grisel, and L Thybaud, and D Arstrong, and C Depeursinge, and A L Blum
Division of Gastroenterology, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland.

Intraluminal pH monitoring in man should be performed with disposable multichannel assemblies that allow recordings at multiple sites and prevent transmission of infection. Currently available glass electrodes are unsuitable for this purpose because of their size and price. We have thus constructed and tested a small, combined ion sensitive field effect transistor (ISFET) pH electrode incorporating an integral reference electrode. In vitro studies showed that both ISFET and glass electrodes (440-M4, Ingold, Switzerland) have a linear response over the pH range 1.3-8.0 and that they are comparable with regard to response time and 24 hour drift. Twenty one hour intragastric pH recordings were performed simultaneously in eight healthy volunteers using a glass electrode and an ISFET electrode, placed no more than 2 mm apart in a combined assembly. This was located in the gastric corpus under fluoroscopic control. The 21 hour pH curves recorded by each electrode type showed identical patterns: an early morning rise in pH with three meal-associated pH peaks lasting for about two to three hours. The means of the 21 hour pH medians were 2.09 and 2.07 as measured by the glass and the ISFET electrodes respectively. Thus, ISFETs are suitable for the construction of inexpensive and hence disposable multichannel pH monitoring assemblies of small diameter. Provided that they can be produced in large numbers with appropriate technical support, ISFETs have the potential to replace glass electrodes for long term monitoring of gastrointestinal luminal acidity.

UI MeSH Term Description Entries
D008297 Male Males
D008839 Microelectrodes Electrodes with an extremely small tip, used in a voltage clamp or other apparatus to stimulate or record bioelectric potentials of single cells intracellularly or extracellularly. (Dorland, 28th ed) Electrodes, Miniaturized,Electrode, Miniaturized,Microelectrode,Miniaturized Electrode,Miniaturized Electrodes
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D008991 Monitoring, Physiologic The continuous measurement of physiological processes, blood pressure, heart rate, renal output, reflexes, respiration, etc., in a patient or experimental animal; includes pharmacologic monitoring, the measurement of administered drugs or their metabolites in the blood, tissues, or urine. Patient Monitoring,Monitoring, Physiological,Physiologic Monitoring,Monitoring, Patient,Physiological Monitoring
D005069 Evaluation Studies as Topic Works about studies that determine the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. Critique,Evaluation Indexes,Evaluation Methodology,Evaluation Report,Evaluation Research,Methodology, Evaluation,Pre-Post Tests,Qualitative Evaluation,Quantitative Evaluation,Theoretical Effectiveness,Use-Effectiveness,Critiques,Effectiveness, Theoretical,Evaluation Methodologies,Evaluation Reports,Evaluation, Qualitative,Evaluation, Quantitative,Evaluations, Qualitative,Evaluations, Quantitative,Indexes, Evaluation,Methodologies, Evaluation,Pre Post Tests,Pre-Post Test,Qualitative Evaluations,Quantitative Evaluations,Report, Evaluation,Reports, Evaluation,Research, Evaluation,Test, Pre-Post,Tests, Pre-Post,Use Effectiveness
D005260 Female Females
D005745 Gastric Acidity Determination Gastric analysis for determination of free acid or total acid. Acidity Determination, Gastric,Acidity Determinations, Gastric,Determination, Gastric Acidity,Determinations, Gastric Acidity,Gastric Acidity Determinations
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D013997 Time Factors Elements of limited time intervals, contributing to particular results or situations. Time Series,Factor, Time,Time Factor

Related Publications

P Duroux, and C Emde, and P Bauerfeind, and C Francis, and A Grisel, and L Thybaud, and D Arstrong, and C Depeursinge, and A L Blum
February 2013, Journal of nanoscience and nanotechnology,
P Duroux, and C Emde, and P Bauerfeind, and C Francis, and A Grisel, and L Thybaud, and D Arstrong, and C Depeursinge, and A L Blum
January 2007, Chemistry (Weinheim an der Bergstrasse, Germany),
P Duroux, and C Emde, and P Bauerfeind, and C Francis, and A Grisel, and L Thybaud, and D Arstrong, and C Depeursinge, and A L Blum
December 2020, Sensors (Basel, Switzerland),
P Duroux, and C Emde, and P Bauerfeind, and C Francis, and A Grisel, and L Thybaud, and D Arstrong, and C Depeursinge, and A L Blum
December 2017, Mikrochimica acta,
P Duroux, and C Emde, and P Bauerfeind, and C Francis, and A Grisel, and L Thybaud, and D Arstrong, and C Depeursinge, and A L Blum
December 2011, The Analyst,
P Duroux, and C Emde, and P Bauerfeind, and C Francis, and A Grisel, and L Thybaud, and D Arstrong, and C Depeursinge, and A L Blum
January 2021, Journal of electronic materials,
P Duroux, and C Emde, and P Bauerfeind, and C Francis, and A Grisel, and L Thybaud, and D Arstrong, and C Depeursinge, and A L Blum
January 2023, Talanta,
P Duroux, and C Emde, and P Bauerfeind, and C Francis, and A Grisel, and L Thybaud, and D Arstrong, and C Depeursinge, and A L Blum
January 2009, Sensors (Basel, Switzerland),
P Duroux, and C Emde, and P Bauerfeind, and C Francis, and A Grisel, and L Thybaud, and D Arstrong, and C Depeursinge, and A L Blum
November 2021, ACS omega,
P Duroux, and C Emde, and P Bauerfeind, and C Francis, and A Grisel, and L Thybaud, and D Arstrong, and C Depeursinge, and A L Blum
November 2019, Analytical biochemistry,
Copied contents to your clipboard!