Quantitative determination of plasma vitamin K1 by high-performance liquid chromatography coupled to isotope dilution tandem mass spectrometry. 2010

Véronique Ducros, and Mickaël Pollicand, and François Laporte, and Alain Favier
Département de Biologie Intégrée, Centre Hospitalier Universitaire, 38043 Grenoble, France. vducros@chu-grenoble.fr

Plasma vitamin K1 (phylloquinone) determination is commonly used for the diagnosis of vitamin K deficiency in patients suffering from lipid malabsorption. Moreover, current evidence that adequate vitamin K intake, and correspondingly adequate plasma vitamin K1 concentration, could also be of importance in relation to bone and brain diseases emphasizes the need to improve the current analytical methods. We developed a liquid chromatography coupled to tandem mass spectrometry method using a stable isotope ring-D4-labeled internal standard of vitamin K1 and operating in the multiple reaction monitoring mode by the selection of a precursor and product ions. The atmospheric pressure chemical ionization (APCI) method was shown to be more sensitive than electrospray ionization. After a single-step extraction with cyclohexane, chromatographic separation was performed on a C18 column with an isocratic mobile phase. The linearity was up to 5400ng/L, and the limit of detection was 14ng/L. Intra- and interrun precision were 2.4% and 8.3%, respectively, for the lower limit of the reference range. Recovery was better than 98%. The method is simple and reliable, allowing accurate vitamin K1 measurement in plasma samples from healthy subjects and patients suffering from vitamin K deficiency.

UI MeSH Term Description Entries
D007553 Isotope Labeling Techniques for labeling a substance with a stable or radioactive isotope. It is not used for articles involving labeled substances unless the methods of labeling are substantively discussed. Tracers that may be labeled include chemical substances, cells, or microorganisms. Isotope Labeling, Stable,Isotope-Coded Affinity Tagging,Isotopically-Coded Affinity Tagging,Affinity Tagging, Isotope-Coded,Affinity Tagging, Isotopically-Coded,Isotope Coded Affinity Tagging,Labeling, Isotope,Labeling, Stable Isotope,Stable Isotope Labeling,Tagging, Isotope-Coded Affinity,Tagging, Isotopically-Coded Affinity
D010837 Vitamin K 1 A family of phylloquinones that contains a ring of 2-methyl-1,4-naphthoquinone and an isoprenoid side chain. Members of this group of vitamin K 1 have only one double bond on the proximal isoprene unit. Rich sources of vitamin K 1 include green plants, algae, and photosynthetic bacteria. Vitamin K1 has antihemorrhagic and prothrombogenic activity. Phylloquinone,Phytomenadione,Phytonadione,Aquamephyton,Konakion,Phyllohydroquinone,Vitamin K1
D002851 Chromatography, High Pressure Liquid Liquid chromatographic techniques which feature high inlet pressures, high sensitivity, and high speed. Chromatography, High Performance Liquid,Chromatography, High Speed Liquid,Chromatography, Liquid, High Pressure,HPLC,High Performance Liquid Chromatography,High-Performance Liquid Chromatography,UPLC,Ultra Performance Liquid Chromatography,Chromatography, High-Performance Liquid,High-Performance Liquid Chromatographies,Liquid Chromatography, High-Performance
D003510 Cyclohexanes Six-carbon alicyclic hydrocarbons.
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D014813 Vitamin K Deficiency A nutritional condition produced by a deficiency of VITAMIN K in the diet, characterized by an increased tendency to hemorrhage (HEMORRHAGIC DISORDERS). Such bleeding episodes may be particularly severe in newborn infants. (From Cecil Textbook of Medicine, 19th ed, p1182) Deficiency, Vitamin K,Deficiencies, Vitamin K,Vitamin K Deficiencies
D053719 Tandem Mass Spectrometry A mass spectrometry technique using two (MS/MS) or more mass analyzers. With two in tandem, the precursor ions are mass-selected by a first mass analyzer, and focused into a collision region where they are then fragmented into product ions which are then characterized by a second mass analyzer. A variety of techniques are used to separate the compounds, ionize them, and introduce them to the first mass analyzer. For example, for in GC-MS/MS, GAS CHROMATOGRAPHY-MASS SPECTROMETRY is involved in separating relatively small compounds by GAS CHROMATOGRAPHY prior to injecting them into an ionization chamber for the mass selection. Mass Spectrometry-Mass Spectrometry,Mass Spectrometry Mass Spectrometry,Mass Spectrometry, Tandem

Related Publications

Véronique Ducros, and Mickaël Pollicand, and François Laporte, and Alain Favier
October 2004, Journal of chromatography. A,
Véronique Ducros, and Mickaël Pollicand, and François Laporte, and Alain Favier
October 2004, Journal of chromatography. A,
Véronique Ducros, and Mickaël Pollicand, and François Laporte, and Alain Favier
August 2020, Molecular medicine reports,
Véronique Ducros, and Mickaël Pollicand, and François Laporte, and Alain Favier
May 2020, Biomedical chromatography : BMC,
Véronique Ducros, and Mickaël Pollicand, and François Laporte, and Alain Favier
August 2013, Clinical chemistry,
Véronique Ducros, and Mickaël Pollicand, and François Laporte, and Alain Favier
April 2019, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences,
Véronique Ducros, and Mickaël Pollicand, and François Laporte, and Alain Favier
April 2019, Se pu = Chinese journal of chromatography,
Véronique Ducros, and Mickaël Pollicand, and François Laporte, and Alain Favier
January 2001, Phytochemical analysis : PCA,
Véronique Ducros, and Mickaël Pollicand, and François Laporte, and Alain Favier
November 2019, Journal of dairy science,
Copied contents to your clipboard!