Catheter ablation of atrioventricular junction using radiofrequency current in 17 patients. Comparison of standard and large-tip catheter electrodes. 1991

W M Jackman, and X Z Wang, and K J Friday, and D M Fitzgerald, and C Roman, and K Moulton, and P D Margolis, and A J Bowman, and K H Kuck, and G V Naccarelli
Department of Medicine, University of Oklahoma Health Sciences Center, Oklahoma City 73190.

BACKGROUND Two catheter electrode systems were compared for delivering radiofrequency current for ablation of the atrioventricular junction. Seventeen patients with drug-resistant supraventricular tachyarrhythmias were studied. RESULTS A 6F or 7F catheter with six or eight standard electrodes (1.25 mm wide, 2.5-mm spacing) was used in the first seven patients (group 1). A 7F quadripolar catheter with a large-tip electrode (4 mm long; surface area, 27 mm2) was used in the final 10 patients (group 2). Both ablation catheters were positioned to record a large atrial potential and a small but sharp His bundle potential from the distal bipolar electrode pair. Radiofrequency current was applied between a large skin electrode on the left posterior chest and either 1) each individual electrode on the standard-tip electrode catheter at 40 V (group 1) or 2) the large-tip electrode at 50-60 V (group 2). Radiofrequency current was limited to 40 V in group patients because of the strong potential for an early impedance rise when higher voltage is applied through standard electrodes. Complete atrioventricular block was achieved in six of seven group 1 patients and all 10 group 2 patients. A junctional escape rhythm followed ablation in five or six group 1 patients (mean cycle length, 1,066 +/- 162 msec) and eight of 10 group 2 patients (mean cycle length, 1,281 +/- 231 msec). Atrioventricular block was produced in a mean of 4.7 +/- 4.6 radiofrequency current applications delivered over a period of 42 +/- 45 minutes using the large-tip electrode (group 2) compared with 46 +/- 22 applications using standard electrodes (15.9 +/- 10.2 applications delivered through the standard-tip electrode) over a period of 147 +/- 59 minutes (group 1). For the application producing atrioventricular block, the large-tip electrode used higher voltage (58 +/- 17 versus 38 +/- 5 V, p less than 0.03) and had lower impedance (103 +/- 22 versus 148 +/- 40 omega, p less than 0.01), resulting in greater power (33.0 +/- 13.0 versus 10.2 +/- 0.6 W, p less than 0.003) and shorter time to block (8 +/- 3 versus 22 +/- 3 seconds, p less than 0.001). Current delivery through standard electrodes was limited by an impedance rise occurring 7 +/- 7 seconds after the onset of one or more radiofrequency current applications at 10 +/- 1 W in six of seven patients. Using the large-tip electrode, an impedance rise occurred in five of 10 patients, but at 25 +/- 10 W and after 21 +/- 9 seconds. Atrioventricular block occurred before the impedance rise in three of these five patients. Complete atrioventricular block persisted in 15 of 16 patients at a mean follow-up of 8.7 months. Atrioventricular conduction returned at 1 month in one group 2 patient and was successfully ablated by a second procedure. Three group 1 patients died 0.5-2 months after ablation, and a fourth patient underwent cardiac transplantation after 10 months. Pathological examination of the heart in two of these patients showed necrosis of the atrioventricular node and origin of the His bundle, without injury to the middle or distal His bundle. All 10 group 2 patients are alive and subjectively improved after ablation. CONCLUSIONS We conclude that catheter-delivered radiofrequency current effectively produces complete atrioventricular block (94%) without requiring general anesthesia or the risk of ventricular dysfunction or cardiac perforation. The large-tip electrode allows a threefold increase in delivered power and markedly decreases the number of pulses and time required to produce atrioventricular block.

UI MeSH Term Description Entries
D009206 Myocardium The muscle tissue of the HEART. It is composed of striated, involuntary muscle cells (MYOCYTES, CARDIAC) connected to form the contractile pump to generate blood flow. Muscle, Cardiac,Muscle, Heart,Cardiac Muscle,Myocardia,Cardiac Muscles,Heart Muscle,Heart Muscles,Muscles, Cardiac,Muscles, Heart
D011184 Postoperative Period The period following a surgical operation. Period, Postoperative,Periods, Postoperative,Postoperative Periods
D011846 Radio Waves Electromagnetic waves with frequencies between about 3 kilohertz (very low frequency - VLF) and 300,000 megahertz (extremely high frequency - EHF). They are used in television and radio broadcasting, land and satellite communications systems, radionavigation, radiolocation, and DIATHERMY. The highest frequency radio waves are MICROWAVES. Hertzian Waves,High Frequency Waves,Radiowave,Radiowaves,Short Waves,Very High Frequency Waves,Frequency Wave, High,Frequency Waves, High,High Frequency Wave,Radio Wave,Short Wave,Wave, High Frequency,Wave, Radio,Wave, Short,Waves, Hertzian,Waves, High Frequency,Waves, Radio,Waves, Short
D004566 Electrodes Electric conductors through which electric currents enter or leave a medium, whether it be an electrolytic solution, solid, molten mass, gas, or vacuum. Anode,Anode Materials,Cathode,Cathode Materials,Anode Material,Anodes,Cathode Material,Cathodes,Electrode,Material, Anode,Material, Cathode
D004867 Equipment Design Methods and patterns of fabricating machines and related hardware. Design, Equipment,Device Design,Medical Device Design,Design, Medical Device,Designs, Medical Device,Device Design, Medical,Device Designs, Medical,Medical Device Designs,Design, Device,Designs, Device,Designs, Equipment,Device Designs,Equipment Designs
D005500 Follow-Up Studies Studies in which individuals or populations are followed to assess the outcome of exposures, procedures, or effects of a characteristic, e.g., occurrence of disease. Followup Studies,Follow Up Studies,Follow-Up Study,Followup Study,Studies, Follow-Up,Studies, Followup,Study, Follow-Up,Study, Followup
D006321 Heart The hollow, muscular organ that maintains the circulation of the blood. Hearts
D006328 Cardiac Catheterization Procedures in which placement of CARDIAC CATHETERS is performed for therapeutic or diagnostic procedures. Catheterization, Cardiac,Catheterization, Heart,Heart Catheterization,Cardiac Catheterizations,Catheterizations, Cardiac,Catheterizations, Heart,Heart Catheterizations
D006348 Cardiac Surgical Procedures Surgery performed on the heart. Cardiac Surgical Procedure,Heart Surgical Procedure,Heart Surgical Procedures,Procedure, Cardiac Surgical,Procedure, Heart Surgical,Procedures, Cardiac Surgical,Procedures, Heart Surgical,Surgical Procedure, Cardiac,Surgical Procedure, Heart,Surgical Procedures, Cardiac,Surgical Procedures, Heart
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

W M Jackman, and X Z Wang, and K J Friday, and D M Fitzgerald, and C Roman, and K Moulton, and P D Margolis, and A J Bowman, and K H Kuck, and G V Naccarelli
October 1994, Australian and New Zealand journal of medicine,
W M Jackman, and X Z Wang, and K J Friday, and D M Fitzgerald, and C Roman, and K Moulton, and P D Margolis, and A J Bowman, and K H Kuck, and G V Naccarelli
March 1993, Journal of the American College of Cardiology,
W M Jackman, and X Z Wang, and K J Friday, and D M Fitzgerald, and C Roman, and K Moulton, and P D Margolis, and A J Bowman, and K H Kuck, and G V Naccarelli
May 1993, International journal of cardiology,
W M Jackman, and X Z Wang, and K J Friday, and D M Fitzgerald, and C Roman, and K Moulton, and P D Margolis, and A J Bowman, and K H Kuck, and G V Naccarelli
December 1989, Circulation,
W M Jackman, and X Z Wang, and K J Friday, and D M Fitzgerald, and C Roman, and K Moulton, and P D Margolis, and A J Bowman, and K H Kuck, and G V Naccarelli
August 2012, Journal of cardiovascular electrophysiology,
W M Jackman, and X Z Wang, and K J Friday, and D M Fitzgerald, and C Roman, and K Moulton, and P D Margolis, and A J Bowman, and K H Kuck, and G V Naccarelli
December 2006, Prilozi,
W M Jackman, and X Z Wang, and K J Friday, and D M Fitzgerald, and C Roman, and K Moulton, and P D Margolis, and A J Bowman, and K H Kuck, and G V Naccarelli
June 1991, Lancet (London, England),
W M Jackman, and X Z Wang, and K J Friday, and D M Fitzgerald, and C Roman, and K Moulton, and P D Margolis, and A J Bowman, and K H Kuck, and G V Naccarelli
January 1991, The American journal of cardiology,
W M Jackman, and X Z Wang, and K J Friday, and D M Fitzgerald, and C Roman, and K Moulton, and P D Margolis, and A J Bowman, and K H Kuck, and G V Naccarelli
December 1992, The American journal of cardiology,
W M Jackman, and X Z Wang, and K J Friday, and D M Fitzgerald, and C Roman, and K Moulton, and P D Margolis, and A J Bowman, and K H Kuck, and G V Naccarelli
September 2011, Journal of cardiovascular electrophysiology,
Copied contents to your clipboard!