Effect of mean airway pressure on gas exchange during high-frequency oscillatory ventilation. 1991

B R Boynton, and D Villanueva, and M D Hammond, and P N Vreeland, and B Buckley, and I D Frantz
Department of Pediatrics, University of Kentucky College of Medicine, Lexington 40536.

We studied the effect of mean airway pressure (Paw) on gas exchange during high-frequency oscillatory ventilation in 14 adult rabbits before and after pulmonary saline lavage. Sinusoidal volume changes were delivered through a tracheostomy at 16 Hz, a tidal volume of 1 or 2 ml/kg, and inspired O2 fraction of 0.5. Arterial PO2 and PCO2 (PaO2, PaCO2), lung volume change, and venous admixture were measured at Paw from 5 to 25 cmH2O after either deflation from total lung capacity or inflation from relaxation volume (Vr). The rabbits were lavaged with saline until PaO2 was less than 70 Torr, and all measurements were repeated. Lung volume change was measured in a pressure plethysmograph. Raising Paw from 5 to 25 cmH2O increased lung volume by 48-50 ml above Vr in both healthy and lavaged rabbits. Before lavage, PaO2 was relatively insensitive to changes in Paw, but after lavage PaO2 increased with Paw from 42.8 +/- 7.8 to 137.3 +/- 18.3 (SE) Torr (P less than 0.001). PaCO2 was insensitive to Paw change before and after lavage. At each Paw after lavage, lung volume was larger, venous admixture smaller, and PaO2 higher after deflation from total lung capacity than after inflation from Vr. This study shows that the effect of increased Paw on PaO2 is mediated through an increase in lung volume. In saline-lavaged lungs, equal distending pressures do not necessarily imply equal lung volumes and thus do not imply equal PaO2.

UI MeSH Term Description Entries
D008176 Lung Volume Measurements Measurement of the amount of air that the lungs may contain at various points in the respiratory cycle. Lung Capacities,Lung Volumes,Capacity, Lung,Lung Capacity,Lung Volume,Lung Volume Measurement,Measurement, Lung Volume,Volume, Lung
D010100 Oxygen An element with atomic symbol O, atomic number 8, and atomic weight [15.99903; 15.99977]. It is the most abundant element on earth and essential for respiration. Dioxygen,Oxygen-16,Oxygen 16
D011312 Pressure A type of stress exerted uniformly in all directions. Its measure is the force exerted per unit area. (McGraw-Hill Dictionary of Scientific and Technical Terms, 6th ed) Pressures
D011659 Pulmonary Gas Exchange The exchange of OXYGEN and CARBON DIOXIDE between alveolar air and pulmonary capillary blood that occurs across the BLOOD-AIR BARRIER. Exchange, Pulmonary Gas,Gas Exchange, Pulmonary
D011817 Rabbits A burrowing plant-eating mammal with hind limbs that are longer than its fore limbs. It belongs to the family Leporidae of the order Lagomorpha, and in contrast to hares, possesses 22 instead of 24 pairs of chromosomes. Belgian Hare,New Zealand Rabbit,New Zealand Rabbits,New Zealand White Rabbit,Rabbit,Rabbit, Domestic,Chinchilla Rabbits,NZW Rabbits,New Zealand White Rabbits,Oryctolagus cuniculus,Chinchilla Rabbit,Domestic Rabbit,Domestic Rabbits,Hare, Belgian,NZW Rabbit,Rabbit, Chinchilla,Rabbit, NZW,Rabbit, New Zealand,Rabbits, Chinchilla,Rabbits, Domestic,Rabbits, NZW,Rabbits, New Zealand,Zealand Rabbit, New,Zealand Rabbits, New,cuniculus, Oryctolagus
D006612 High-Frequency Ventilation Ventilatory support system using frequencies from 60-900 cycles/min or more. Three types of systems have been distinguished on the basis of rates, volumes, and the system used. They are high frequency positive-pressure ventilation (HFPPV); HIGH-FREQUENCY JET VENTILATION; (HFJV); and high-frequency oscillation (HFO). High-Frequency Oscillation Ventilation,High-Frequency Positive Pressure Ventilation,Ventilation, High-Frequency,High Frequency Oscillation Ventilation,High Frequency Positive Pressure Ventilation,High Frequency Ventilation,Ventilation, High Frequency,High Frequency Ventilations,High-Frequency Oscillation Ventilations,High-Frequency Ventilations,Oscillation Ventilation, High-Frequency,Oscillation Ventilations, High-Frequency,Ventilation, High-Frequency Oscillation,Ventilations, High Frequency,Ventilations, High-Frequency,Ventilations, High-Frequency Oscillation
D000818 Animals Unicellular or multicellular, heterotrophic organisms, that have sensation and the power of voluntary movement. Under the older five kingdom paradigm, Animalia was one of the kingdoms. Under the modern three domain model, Animalia represents one of the many groups in the domain EUKARYOTA. Animal,Metazoa,Animalia
D015656 Respiratory Mechanics The physical or mechanical action of the LUNGS; DIAPHRAGM; RIBS; and CHEST WALL during respiration. It includes airflow, lung volume, neural and reflex controls, mechanoreceptors, breathing patterns, etc. Breathing Mechanics,Breathing Mechanic,Mechanic, Breathing,Mechanic, Respiratory,Mechanics, Breathing,Mechanics, Respiratory,Respiratory Mechanic

Related Publications

B R Boynton, and D Villanueva, and M D Hammond, and P N Vreeland, and B Buckley, and I D Frantz
May 1988, Critical care medicine,
B R Boynton, and D Villanueva, and M D Hammond, and P N Vreeland, and B Buckley, and I D Frantz
June 1988, Pediatric research,
B R Boynton, and D Villanueva, and M D Hammond, and P N Vreeland, and B Buckley, and I D Frantz
January 1984, Critical care medicine,
B R Boynton, and D Villanueva, and M D Hammond, and P N Vreeland, and B Buckley, and I D Frantz
December 2017, Pediatric research,
B R Boynton, and D Villanueva, and M D Hammond, and P N Vreeland, and B Buckley, and I D Frantz
November 1986, Journal of applied physiology (Bethesda, Md. : 1985),
B R Boynton, and D Villanueva, and M D Hammond, and P N Vreeland, and B Buckley, and I D Frantz
April 1998, American journal of respiratory and critical care medicine,
B R Boynton, and D Villanueva, and M D Hammond, and P N Vreeland, and B Buckley, and I D Frantz
July 1999, Journal of applied physiology (Bethesda, Md. : 1985),
B R Boynton, and D Villanueva, and M D Hammond, and P N Vreeland, and B Buckley, and I D Frantz
July 2002, Critical care medicine,
B R Boynton, and D Villanueva, and M D Hammond, and P N Vreeland, and B Buckley, and I D Frantz
October 1984, Journal of applied physiology: respiratory, environmental and exercise physiology,
B R Boynton, and D Villanueva, and M D Hammond, and P N Vreeland, and B Buckley, and I D Frantz
September 1984, Critical care medicine,
Copied contents to your clipboard!