Influence of calibration method on distortion-product otoacoustic emission measurements: I. test performance. 2010

Sienna R Burke, and Abigail R Rogers, and Stephen T Neely, and Judy G Kopun, and Hongyang Tan, and Michael P Gorga
Department of Hearing and Speech Sciences, University of Maryland, College Park, Maryland, USA.

OBJECTIVE Calibration errors in distortion-product otoacoustic emission (DPOAE) measurements because of standing waves cause unpredictable changes in stimulus and DPOAE response level. The purpose of this study was to assess the extent to which these errors affect DPOAE test performance. Standard calibration procedures use sound pressure level (SPL) to determine specified levels. Forward pressure level (FPL) is an alternate calibration method that is less susceptible to standing waves. However, FPL derivation requires prior cavity measurements, which have associated variability. In an attempt to address this variability, four FPL methods were compared with SPL: a reference calibration derived from 25 measurements before all data collection and a daily calibration measurement, both of which were made at body and room temperature. METHODS Data were collected from 52 normal-hearing and 103 hearing-impaired subjects. DPOAEs were measured for f2 frequencies ranging from 2 to 8 kHz in half-octave steps, with L2 ranging from -20 to 70 dB SPL (5-dB steps). At each f2, DPOAEs were measured in five calibration conditions: SPL, daily FPL at body temperature (daily body), daily FPL at room temperature (daily room), reference FPL at body temperature (ref body), and reference FPL at room temperature (ref room). Data were used to construct receiver operating characteristic (ROC) curves for each f2, calibration method, and L2. From these curves, areas under the ROC curve (AROC) were estimated. RESULTS The results of this study are summarized by the following observations: (1) DPOAE test performance was sensitive to stimulus level, regardless of calibration method, with the best test performance observed for moderate stimulus level conditions. (2) An effect of frequency was observed for all calibration methods, with the best test performance at 6 kHz and the worst performance at 8 kHz. (3) At clinically applicable stimulus levels, little difference in test performance among calibration methods was noted across frequencies, except at 8 kHz. At 8 kHz, FPL-based calibration methods provided superior performance compared with the standard SPL calibration. (4) A difference between FPL calibration methods was observed at 8 kHz, with the best test performance occurring for daily calibrations at body temperature. CONCLUSIONS With the exception of 8 kHz, there was little difference in test performance across calibration methods. At 8 kHz, AROCs and specificities for fixed sensitivities indicate that FPL-based calibration methods provide superior performance compared with the standard SPL calibration for clinically relevant levels. Temperature may have an impact on FPL calculations relative to DPOAE test performance. Although the differences in AROC among calibration procedures were not statistically significant, the present results indicate that standing wave errors may impact DPOAE test performance and can be reduced by using FPL, although the largest effects were restricted to 8 kHz.

UI MeSH Term Description Entries
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D010469 Perceptual Distortion Lack of correspondence between the way a stimulus is commonly perceived and the way an individual perceives it under given conditions. Distortion, Perceptual,Distortions, Perceptual,Perceptual Distortions
D012016 Reference Values The range or frequency distribution of a measurement in a population (of organisms, organs or things) that has not been selected for the presence of disease or abnormality. Normal Range,Normal Values,Reference Ranges,Normal Ranges,Normal Value,Range, Normal,Range, Reference,Ranges, Normal,Ranges, Reference,Reference Range,Reference Value,Value, Normal,Value, Reference,Values, Normal,Values, Reference
D002138 Calibration Determination, by measurement or comparison with a standard, of the correct value of each scale reading on a meter or other measuring instrument; or determination of the settings of a control device that correspond to particular values of voltage, current, frequency or other output. Calibrations
D002648 Child A person 6 to 12 years of age. An individual 2 to 5 years old is CHILD, PRESCHOOL. Children
D006311 Hearing Disorders Conditions that impair the transmission of auditory impulses and information from the level of the ear to the temporal cortices, including the sensorineural pathways. Distorted Hearing,Dysacusis,Paracousis,Paracusis,Hearing Disorder,Hearing, Distorted
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000293 Adolescent A person 13 to 18 years of age. Adolescence,Youth,Adolescents,Adolescents, Female,Adolescents, Male,Teenagers,Teens,Adolescent, Female,Adolescent, Male,Female Adolescent,Female Adolescents,Male Adolescent,Male Adolescents,Teen,Teenager,Youths
D000328 Adult A person having attained full growth or maturity. Adults are of 19 through 44 years of age. For a person between 19 and 24 years of age, YOUNG ADULT is available. Adults
D000368 Aged A person 65 years of age or older. For a person older than 79 years, AGED, 80 AND OVER is available. Elderly

Related Publications

Sienna R Burke, and Abigail R Rogers, and Stephen T Neely, and Judy G Kopun, and Hongyang Tan, and Michael P Gorga
January 2013, Ear and hearing,
Sienna R Burke, and Abigail R Rogers, and Stephen T Neely, and Judy G Kopun, and Hongyang Tan, and Michael P Gorga
February 2011, Ear and hearing,
Sienna R Burke, and Abigail R Rogers, and Stephen T Neely, and Judy G Kopun, and Hongyang Tan, and Michael P Gorga
July 2008, The Journal of the Acoustical Society of America,
Sienna R Burke, and Abigail R Rogers, and Stephen T Neely, and Judy G Kopun, and Hongyang Tan, and Michael P Gorga
January 2011, Ear and hearing,
Sienna R Burke, and Abigail R Rogers, and Stephen T Neely, and Judy G Kopun, and Hongyang Tan, and Michael P Gorga
July 1997, The Journal of the Acoustical Society of America,
Sienna R Burke, and Abigail R Rogers, and Stephen T Neely, and Judy G Kopun, and Hongyang Tan, and Michael P Gorga
January 1999, Hearing research,
Sienna R Burke, and Abigail R Rogers, and Stephen T Neely, and Judy G Kopun, and Hongyang Tan, and Michael P Gorga
October 2007, The Journal of the Acoustical Society of America,
Sienna R Burke, and Abigail R Rogers, and Stephen T Neely, and Judy G Kopun, and Hongyang Tan, and Michael P Gorga
October 2003, Lin chuang er bi yan hou ke za zhi = Journal of clinical otorhinolaryngology,
Sienna R Burke, and Abigail R Rogers, and Stephen T Neely, and Judy G Kopun, and Hongyang Tan, and Michael P Gorga
September 1994, The Journal of the Acoustical Society of America,
Sienna R Burke, and Abigail R Rogers, and Stephen T Neely, and Judy G Kopun, and Hongyang Tan, and Michael P Gorga
February 2011, The Journal of the Acoustical Society of America,
Copied contents to your clipboard!