Comparison of the accuracy of multidetector computed tomography versus two-dimensional echocardiography to measure left atrial volume. 2010

Erick Avelar, and Ronen Durst, and Guido A Rosito, and Molly Thangaroopan, and Simi Kumar, and Francois Tournoux, and Raymond C Chan, and Judy Hung, and Udo Hoffmann, and Suhny Abbara, and Thomas Brady, and Ricardo C Cury
Department of Cardiology, University of Connecticut Health Center, Farmington, CT, USA. eavelar@uchc.edu

Left atrial (LA) volume is an important prognostic factor in cardiovascular disease. Multidetector computed tomography (MDCT) is an emerging cardiac imaging modality; however, its accuracy in measuring the LA volume has not been well studied. The aim of our study was to determine the accuracy of MDCT in quantifying the LA volume. A total of 48 patients underwent MDCT and 2-dimensional (2D) echocardiography (2DE) on the same day. The area-length and Simpson's methods were used to obtain the 2D echocardiographic LA volume. The LA volume assessment by MDCT was obtained using the modified Simpson's method. Four artificial phantoms were created, and their true volume was assessed by an independent observer using both imaging modalities. The correlation between the LA volume by MDCT and 2DE was significant (r = 0.68). The mean 2D echocardiographic LA volume was lower than the LA volume obtained with MDCT (2DE 79 +/- 37 vs MDCT 103 +/- 32, p <0.05). In the phantom experiment, the volume obtained using MDCT and 2DE correlated significantly with the true volume (r = 0.97, p <0.05 vs r = 0.96, p <0.05, respectively). However, the mean 2D echocardiographic phantom volume was 16% lower than the true volume (2DE, Simpson's method 53 +/- 24 vs the true volume 61 +/- 24, p <0.05). The mean volume calculated using MDCT did not differ from the true volume (MDCT 60 +/- 21 vs true volume 61 +/- 24, p = NS). 2DE appeared to systematically underestimate the LA volume compared to phantom and cardiac MDCT, suggesting that different normal cutoff values should be used for each modality. In conclusion, LA volume quantification using MDCT is an accurate and feasible method.

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D009929 Organ Size The measurement of an organ in volume, mass, or heaviness. Organ Volume,Organ Weight,Size, Organ,Weight, Organ
D004452 Echocardiography Ultrasonic recording of the size, motion, and composition of the heart and surrounding tissues. The standard approach is transthoracic. Echocardiography, Contrast,Echocardiography, Cross-Sectional,Echocardiography, M-Mode,Echocardiography, Transthoracic,Echocardiography, Two-Dimensional,Transthoracic Echocardiography,2-D Echocardiography,2D Echocardiography,Contrast Echocardiography,Cross-Sectional Echocardiography,Echocardiography, 2-D,Echocardiography, 2D,M-Mode Echocardiography,Two-Dimensional Echocardiography,2 D Echocardiography,Cross Sectional Echocardiography,Echocardiography, 2 D,Echocardiography, Cross Sectional,Echocardiography, M Mode,Echocardiography, Two Dimensional,M Mode Echocardiography,Two Dimensional Echocardiography
D005240 Feasibility Studies Studies to determine the advantages or disadvantages, practicability, or capability of accomplishing a projected plan, study, or project. Feasibility Study,Studies, Feasibility,Study, Feasibility
D005260 Female Females
D006325 Heart Atria The chambers of the heart, to which the BLOOD returns from the circulation. Heart Atrium,Left Atrium,Right Atrium,Atria, Heart,Atrium, Heart,Atrium, Left,Atrium, Right
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000368 Aged A person 65 years of age or older. For a person older than 79 years, AGED, 80 AND OVER is available. Elderly
D014057 Tomography, X-Ray Computed Tomography using x-ray transmission and a computer algorithm to reconstruct the image. CAT Scan, X-Ray,CT Scan, X-Ray,Cine-CT,Computerized Tomography, X-Ray,Electron Beam Computed Tomography,Tomodensitometry,Tomography, Transmission Computed,X-Ray Tomography, Computed,CAT Scan, X Ray,CT X Ray,Computed Tomography, X-Ray,Computed X Ray Tomography,Computerized Tomography, X Ray,Electron Beam Tomography,Tomography, X Ray Computed,Tomography, X-Ray Computer Assisted,Tomography, X-Ray Computerized,Tomography, X-Ray Computerized Axial,Tomography, Xray Computed,X Ray Computerized Tomography,X Ray Tomography, Computed,X-Ray Computer Assisted Tomography,X-Ray Computerized Axial Tomography,Beam Tomography, Electron,CAT Scans, X-Ray,CT Scan, X Ray,CT Scans, X-Ray,CT X Rays,Cine CT,Computed Tomography, Transmission,Computed Tomography, X Ray,Computed Tomography, Xray,Computed X-Ray Tomography,Scan, X-Ray CAT,Scan, X-Ray CT,Scans, X-Ray CAT,Scans, X-Ray CT,Tomographies, Computed X-Ray,Tomography, Computed X-Ray,Tomography, Electron Beam,Tomography, X Ray Computer Assisted,Tomography, X Ray Computerized,Tomography, X Ray Computerized Axial,Transmission Computed Tomography,X Ray Computer Assisted Tomography,X Ray Computerized Axial Tomography,X Ray, CT,X Rays, CT,X-Ray CAT Scan,X-Ray CAT Scans,X-Ray CT Scan,X-Ray CT Scans,X-Ray Computed Tomography,X-Ray Computerized Tomography,Xray Computed Tomography

Related Publications

Erick Avelar, and Ronen Durst, and Guido A Rosito, and Molly Thangaroopan, and Simi Kumar, and Francois Tournoux, and Raymond C Chan, and Judy Hung, and Udo Hoffmann, and Suhny Abbara, and Thomas Brady, and Ricardo C Cury
August 2019, The American journal of cardiology,
Erick Avelar, and Ronen Durst, and Guido A Rosito, and Molly Thangaroopan, and Simi Kumar, and Francois Tournoux, and Raymond C Chan, and Judy Hung, and Udo Hoffmann, and Suhny Abbara, and Thomas Brady, and Ricardo C Cury
April 2019, The American journal of cardiology,
Erick Avelar, and Ronen Durst, and Guido A Rosito, and Molly Thangaroopan, and Simi Kumar, and Francois Tournoux, and Raymond C Chan, and Judy Hung, and Udo Hoffmann, and Suhny Abbara, and Thomas Brady, and Ricardo C Cury
April 1995, The American journal of cardiology,
Erick Avelar, and Ronen Durst, and Guido A Rosito, and Molly Thangaroopan, and Simi Kumar, and Francois Tournoux, and Raymond C Chan, and Judy Hung, and Udo Hoffmann, and Suhny Abbara, and Thomas Brady, and Ricardo C Cury
June 2011, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography,
Erick Avelar, and Ronen Durst, and Guido A Rosito, and Molly Thangaroopan, and Simi Kumar, and Francois Tournoux, and Raymond C Chan, and Judy Hung, and Udo Hoffmann, and Suhny Abbara, and Thomas Brady, and Ricardo C Cury
January 2010, Korean journal of radiology,
Erick Avelar, and Ronen Durst, and Guido A Rosito, and Molly Thangaroopan, and Simi Kumar, and Francois Tournoux, and Raymond C Chan, and Judy Hung, and Udo Hoffmann, and Suhny Abbara, and Thomas Brady, and Ricardo C Cury
March 1991, American heart journal,
Erick Avelar, and Ronen Durst, and Guido A Rosito, and Molly Thangaroopan, and Simi Kumar, and Francois Tournoux, and Raymond C Chan, and Judy Hung, and Udo Hoffmann, and Suhny Abbara, and Thomas Brady, and Ricardo C Cury
November 2013, Echocardiography (Mount Kisco, N.Y.),
Erick Avelar, and Ronen Durst, and Guido A Rosito, and Molly Thangaroopan, and Simi Kumar, and Francois Tournoux, and Raymond C Chan, and Judy Hung, and Udo Hoffmann, and Suhny Abbara, and Thomas Brady, and Ricardo C Cury
December 1983, Journal of cardiography,
Erick Avelar, and Ronen Durst, and Guido A Rosito, and Molly Thangaroopan, and Simi Kumar, and Francois Tournoux, and Raymond C Chan, and Judy Hung, and Udo Hoffmann, and Suhny Abbara, and Thomas Brady, and Ricardo C Cury
August 2019, Journal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology,
Erick Avelar, and Ronen Durst, and Guido A Rosito, and Molly Thangaroopan, and Simi Kumar, and Francois Tournoux, and Raymond C Chan, and Judy Hung, and Udo Hoffmann, and Suhny Abbara, and Thomas Brady, and Ricardo C Cury
October 2005, The American journal of cardiology,
Copied contents to your clipboard!