MRI-assisted PET motion correction for neurologic studies in an integrated MR-PET scanner. 2011

Ciprian Catana, and Thomas Benner, and Andre van der Kouwe, and Larry Byars, and Michael Hamm, and Daniel B Chonde, and Christian J Michel, and Georges El Fakhri, and Matthias Schmand, and A Gregory Sorensen
Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, and Harvard Medical School, Charlestown, Massachusetts 02129, USA. ccatana@nmr.mgh.harvard.edu

Head motion is difficult to avoid in long PET studies, degrading the image quality and offsetting the benefit of using a high-resolution scanner. As a potential solution in an integrated MR-PET scanner, the simultaneously acquired MRI data can be used for motion tracking. In this work, a novel algorithm for data processing and rigid-body motion correction (MC) for the MRI-compatible BrainPET prototype scanner is described, and proof-of-principle phantom and human studies are presented. METHODS To account for motion, the PET prompt and random coincidences and sensitivity data for postnormalization were processed in the line-of-response (LOR) space according to the MRI-derived motion estimates. The processing time on the standard BrainPET workstation is approximately 16 s for each motion estimate. After rebinning in the sinogram space, the motion corrected data were summed, and the PET volume was reconstructed using the attenuation and scatter sinograms in the reference position. The accuracy of the MC algorithm was first tested using a Hoffman phantom. Next, human volunteer studies were performed, and motion estimates were obtained using 2 high-temporal-resolution MRI-based motion-tracking techniques. RESULTS After accounting for the misalignment between the 2 scanners, perfectly coregistered MRI and PET volumes were reproducibly obtained. The MRI output gates inserted into the PET list-mode allow the temporal correlation of the 2 datasets within 0.2 ms. The Hoffman phantom volume reconstructed by processing the PET data in the LOR space was similar to the one obtained by processing the data using the standard methods and applying the MC in the image space, demonstrating the quantitative accuracy of the procedure. In human volunteer studies, motion estimates were obtained from echo planar imaging and cloverleaf navigator sequences every 3 s and 20 ms, respectively. Motion-deblurred PET images, with excellent delineation of specific brain structures, were obtained using these 2 MRI-based estimates. CONCLUSIONS An MRI-based MC algorithm was implemented for an integrated MR-PET scanner. High-temporal-resolution MRI-derived motion estimates (obtained while simultaneously acquiring anatomic or functional MRI data) can be used for PET MC. An MRI-based MC method has the potential to improve PET image quality, increasing its reliability, reproducibility, and quantitative accuracy, and to benefit many neurologic applications.

UI MeSH Term Description Entries
D007090 Image Interpretation, Computer-Assisted Methods developed to aid in the interpretation of ultrasound, radiographic images, etc., for diagnosis of disease. Image Interpretation, Computer Assisted,Computer-Assisted Image Interpretation,Computer-Assisted Image Interpretations,Image Interpretations, Computer-Assisted,Interpretation, Computer-Assisted Image,Interpretations, Computer-Assisted Image
D008279 Magnetic Resonance Imaging Non-invasive method of demonstrating internal anatomy based on the principle that atomic nuclei in a strong magnetic field absorb pulses of radiofrequency energy and emit them as radiowaves which can be reconstructed into computerized images. The concept includes proton spin tomographic techniques. Chemical Shift Imaging,MR Tomography,MRI Scans,MRI, Functional,Magnetic Resonance Image,Magnetic Resonance Imaging, Functional,Magnetization Transfer Contrast Imaging,NMR Imaging,NMR Tomography,Tomography, NMR,Tomography, Proton Spin,fMRI,Functional Magnetic Resonance Imaging,Imaging, Chemical Shift,Proton Spin Tomography,Spin Echo Imaging,Steady-State Free Precession MRI,Tomography, MR,Zeugmatography,Chemical Shift Imagings,Echo Imaging, Spin,Echo Imagings, Spin,Functional MRI,Functional MRIs,Image, Magnetic Resonance,Imaging, Magnetic Resonance,Imaging, NMR,Imaging, Spin Echo,Imagings, Chemical Shift,Imagings, Spin Echo,MRI Scan,MRIs, Functional,Magnetic Resonance Images,Resonance Image, Magnetic,Scan, MRI,Scans, MRI,Shift Imaging, Chemical,Shift Imagings, Chemical,Spin Echo Imagings,Steady State Free Precession MRI
D009038 Motion Physical motion, i.e., a change in position of a body or subject as a result of an external force. It is distinguished from MOVEMENT, a process resulting from biological activity. Motions
D001921 Brain The part of CENTRAL NERVOUS SYSTEM that is contained within the skull (CRANIUM). Arising from the NEURAL TUBE, the embryonic brain is comprised of three major parts including PROSENCEPHALON (the forebrain); MESENCEPHALON (the midbrain); and RHOMBENCEPHALON (the hindbrain). The developed brain consists of CEREBRUM; CEREBELLUM; and other structures in the BRAIN STEM. Encephalon
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000465 Algorithms A procedure consisting of a sequence of algebraic formulas and/or logical steps to calculate or determine a given task. Algorithm
D049268 Positron-Emission Tomography An imaging technique using compounds labelled with short-lived positron-emitting radionuclides (such as carbon-11, nitrogen-13, oxygen-15 and fluorine-18) to measure cell metabolism. It has been useful in study of soft tissues such as CANCER; CARDIOVASCULAR SYSTEM; and brain. SINGLE-PHOTON EMISSION-COMPUTED TOMOGRAPHY is closely related to positron emission tomography, but uses isotopes with longer half-lives and resolution is lower. PET Imaging,PET Scan,Positron-Emission Tomography Imaging,Tomography, Positron-Emission,Imaging, PET,Imaging, Positron-Emission Tomography,PET Imagings,PET Scans,Positron Emission Tomography,Positron Emission Tomography Imaging,Positron-Emission Tomography Imagings,Scan, PET,Tomography Imaging, Positron-Emission,Tomography, Positron Emission
D019047 Phantoms, Imaging Devices or objects in various imaging techniques used to visualize or enhance visualization by simulating conditions encountered in the procedure. Phantoms are used very often in procedures employing or measuring x-irradiation or radioactive material to evaluate performance. Phantoms often have properties similar to human tissue. Water demonstrates absorbing properties similar to normal tissue, hence water-filled phantoms are used to map radiation levels. Phantoms are used also as teaching aids to simulate real conditions with x-ray or ultrasonic machines. (From Iturralde, Dictionary and Handbook of Nuclear Medicine and Clinical Imaging, 1990) Phantoms, Radiographic,Phantoms, Radiologic,Radiographic Phantoms,Radiologic Phantoms,Phantom, Radiographic,Phantom, Radiologic,Radiographic Phantom,Radiologic Phantom,Imaging Phantom,Imaging Phantoms,Phantom, Imaging

Related Publications

Ciprian Catana, and Thomas Benner, and Andre van der Kouwe, and Larry Byars, and Michael Hamm, and Daniel B Chonde, and Christian J Michel, and Georges El Fakhri, and Matthias Schmand, and A Gregory Sorensen
November 2018, Journal of magnetic resonance imaging : JMRI,
Ciprian Catana, and Thomas Benner, and Andre van der Kouwe, and Larry Byars, and Michael Hamm, and Daniel B Chonde, and Christian J Michel, and Georges El Fakhri, and Matthias Schmand, and A Gregory Sorensen
February 2015, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
Ciprian Catana, and Thomas Benner, and Andre van der Kouwe, and Larry Byars, and Michael Hamm, and Daniel B Chonde, and Christian J Michel, and Georges El Fakhri, and Matthias Schmand, and A Gregory Sorensen
June 2012, Annals of nuclear medicine,
Ciprian Catana, and Thomas Benner, and Andre van der Kouwe, and Larry Byars, and Michael Hamm, and Daniel B Chonde, and Christian J Michel, and Georges El Fakhri, and Matthias Schmand, and A Gregory Sorensen
May 2021, Diagnostics (Basel, Switzerland),
Ciprian Catana, and Thomas Benner, and Andre van der Kouwe, and Larry Byars, and Michael Hamm, and Daniel B Chonde, and Christian J Michel, and Georges El Fakhri, and Matthias Schmand, and A Gregory Sorensen
July 2013, Pediatric radiology,
Ciprian Catana, and Thomas Benner, and Andre van der Kouwe, and Larry Byars, and Michael Hamm, and Daniel B Chonde, and Christian J Michel, and Georges El Fakhri, and Matthias Schmand, and A Gregory Sorensen
April 2024, EJNMMI physics,
Ciprian Catana, and Thomas Benner, and Andre van der Kouwe, and Larry Byars, and Michael Hamm, and Daniel B Chonde, and Christian J Michel, and Georges El Fakhri, and Matthias Schmand, and A Gregory Sorensen
February 2015, Medical physics,
Ciprian Catana, and Thomas Benner, and Andre van der Kouwe, and Larry Byars, and Michael Hamm, and Daniel B Chonde, and Christian J Michel, and Georges El Fakhri, and Matthias Schmand, and A Gregory Sorensen
June 2016, Journal of nuclear medicine : official publication, Society of Nuclear Medicine,
Ciprian Catana, and Thomas Benner, and Andre van der Kouwe, and Larry Byars, and Michael Hamm, and Daniel B Chonde, and Christian J Michel, and Georges El Fakhri, and Matthias Schmand, and A Gregory Sorensen
September 2016, Physics in medicine and biology,
Ciprian Catana, and Thomas Benner, and Andre van der Kouwe, and Larry Byars, and Michael Hamm, and Daniel B Chonde, and Christian J Michel, and Georges El Fakhri, and Matthias Schmand, and A Gregory Sorensen
September 2015, European journal of nuclear medicine and molecular imaging,
Copied contents to your clipboard!