Simultaneous quantification of levetiracetam and gabapentin in plasma by ultra-pressure liquid chromatography coupled with tandem mass spectrometry detection. 2011

JoEtta M Juenke, and Paul I Brown, and Kamisha L Johnson-Davis, and Gwendolyn A McMillin
ARUP Institute for Clinical and Experimental Pathology, ARUP Laboratories, Salt Lake City, Utah, USA. juenkejm@aruplab.com

BACKGROUND Gabapentin (Neurontin) and levetiracetam (Keppra) are anticonvulsants with novel structures and suggested therapeutic ranges of 2-10 mg/L and 6-20 mg/L, respectively. Gabapentin is also used extensively to manage neuropathic pain, and for this indication, wherein higher doses are prescribed, plasma concentrations of 15-30 mg/L are typical. OBJECTIVE Here, we describe a simple rapid assay to support therapeutic drug monitoring of gabapentin and levetiracetam in plasma by ultra-pressure liquid chromatography couples to tandem mass spectrometry (UPLC-MS/MS) detection. METHODS After the addition of internal standard and protein precipitation of patient plasma with methanol:acetonitrile in a 50:50 ratio, 1 μL of supernatant sample is injected onto an Acquity UPLC HSS T3, 1.8 μm, 2.1 × 50 mm (Waters) column. Elution occurs using a linear gradient of acetonitrile and water, each having 0.1% formic acid added. The column is eluted into a Waters Acquity UPLC TQD, operating in a positive mode to detect gabapentin at transition 172.18 > 154.11, levetiracetam at 171.11 > 126, and internal standard (3-amino-2-naphthoic acid) at 188.06 > 170. Secondary transitions for each analyte are also monitored for gabapentin at 172.18 > 137.06, levetiracetam at 171.11 > 154, and internal standard at 188.06 > 115. Runtime is 1.5 minutes per injection with baseline resolved chromatographic separation. RESULTS The analytical measurement ranges were 1-150 mg/L for gabapentin and for levetiracetam. Intra-assay imprecision by the coefficient of variance (CV) was less than 8% and interassay CV was less than 5% for both analytes, at 4 different concentrations. Results obtained from patient samples were compared with results generated by established high-performance liquid chromatography-UV methods with the following regression statistics: y = 1.12x - 0.77, r = 0.996, Sy, x = 0.89, and n = 29 for gabapentin and y = 0.991x + 0.70, r = 0.997, Sy, x = 2.24, and n = 30 for levetiracetam. No analytical interferences were identified. CONCLUSIONS : In summary, a simple reliable UPLC-MS/MS method was developed and validated for routine clinical monitoring of gabapentin and levetiracetam.

UI MeSH Term Description Entries
D010889 Piracetam A compound suggested to be both a nootropic and a neuroprotective agent. 2-Pyrrolidone-N-Acetamide,Avigilen,Axonyl,Cerebroforte,Cerepar N,Ciclofalina,Cuxabrain,Dinagen,Gabacet,Geram,Memo-Puren,Nootrop,Nootropil,Nootropyl,Normabraïn,Piracebral,Piracetam AbZ,Piracetam-RPh,Piracetrop,Pirazetam,Pyracetam,Pyramem,Sinapsan,UCB-6215,Memo Puren,Piracetam RPh,UCB 6215,UCB6215
D002853 Chromatography, Liquid Chromatographic techniques in which the mobile phase is a liquid. Liquid Chromatography
D003509 Cyclohexanecarboxylic Acids Carboxylic acid derivatives of cyclohexane. Acids, Cyclohexanecarboxylic
D005680 gamma-Aminobutyric Acid The most common inhibitory neurotransmitter in the central nervous system. 4-Aminobutyric Acid,GABA,4-Aminobutanoic Acid,Aminalon,Aminalone,Gammalon,Lithium GABA,gamma-Aminobutyric Acid, Calcium Salt (2:1),gamma-Aminobutyric Acid, Hydrochloride,gamma-Aminobutyric Acid, Monolithium Salt,gamma-Aminobutyric Acid, Monosodium Salt,gamma-Aminobutyric Acid, Zinc Salt (2:1),4 Aminobutanoic Acid,4 Aminobutyric Acid,Acid, Hydrochloride gamma-Aminobutyric,GABA, Lithium,Hydrochloride gamma-Aminobutyric Acid,gamma Aminobutyric Acid,gamma Aminobutyric Acid, Hydrochloride,gamma Aminobutyric Acid, Monolithium Salt,gamma Aminobutyric Acid, Monosodium Salt
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000077206 Gabapentin A cyclohexane-gamma-aminobutyric acid derivative that is used for the treatment of PARTIAL SEIZURES; NEURALGIA; and RESTLESS LEGS SYNDROME. 1-(Aminomethyl)cyclohexaneacetic Acid,Apo-Gabapentin,Convalis,Gabapentin Hexal,Gabapentin Stada,Gabapentin-Ratiopharm,Neurontin,Novo-Gabapentin,PMS-Gabapentin,Apo Gabapentin,ApoGabapentin,Gabapentin Ratiopharm,Novo Gabapentin,NovoGabapentin
D000077287 Levetiracetam A pyrrolidinone and acetamide derivative that is used primarily for the treatment of SEIZURES and some movement disorders, and as a nootropic agent. Etiracetam,Etiracetam, (R)-,Etiracetam, R-isomer,Etiracetam, S-isomer,Keppra,UCB 6474,UCB-6474,Ucb L059,Ucb L060,Ucb-L059,Ucb-L060,alpha-ethyl-2-oxo-1-Pyrrolidineacetamide,Etiracetam, R isomer,Etiracetam, S isomer,R-isomer Etiracetam,S-isomer Etiracetam,UCB6474,UcbL060,alpha ethyl 2 oxo 1 Pyrrolidineacetamide
D000588 Amines A group of compounds derived from ammonia by substituting organic radicals for the hydrogens. (From Grant & Hackh's Chemical Dictionary, 5th ed) Amine
D000927 Anticonvulsants Drugs used to prevent SEIZURES or reduce their severity. Anticonvulsant,Anticonvulsant Drug,Anticonvulsive Agent,Anticonvulsive Drug,Antiepileptic,Antiepileptic Agent,Antiepileptic Agents,Antiepileptic Drug,Anticonvulsant Drugs,Anticonvulsive Agents,Anticonvulsive Drugs,Antiepileptic Drugs,Antiepileptics,Agent, Anticonvulsive,Agent, Antiepileptic,Agents, Anticonvulsive,Agents, Antiepileptic,Drug, Anticonvulsant,Drug, Anticonvulsive,Drug, Antiepileptic,Drugs, Anticonvulsant,Drugs, Anticonvulsive,Drugs, Antiepileptic
D015203 Reproducibility of Results The statistical reproducibility of measurements (often in a clinical context), including the testing of instrumentation or techniques to obtain reproducible results. The concept includes reproducibility of physiological measurements, which may be used to develop rules to assess probability or prognosis, or response to a stimulus; reproducibility of occurrence of a condition; and reproducibility of experimental results. Reliability and Validity,Reliability of Result,Reproducibility Of Result,Reproducibility of Finding,Validity of Result,Validity of Results,Face Validity,Reliability (Epidemiology),Reliability of Results,Reproducibility of Findings,Test-Retest Reliability,Validity (Epidemiology),Finding Reproducibilities,Finding Reproducibility,Of Result, Reproducibility,Of Results, Reproducibility,Reliabilities, Test-Retest,Reliability, Test-Retest,Result Reliabilities,Result Reliability,Result Validities,Result Validity,Result, Reproducibility Of,Results, Reproducibility Of,Test Retest Reliability,Validity and Reliability,Validity, Face

Related Publications

JoEtta M Juenke, and Paul I Brown, and Kamisha L Johnson-Davis, and Gwendolyn A McMillin
March 2010, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences,
JoEtta M Juenke, and Paul I Brown, and Kamisha L Johnson-Davis, and Gwendolyn A McMillin
February 2006, Journal of pharmaceutical and biomedical analysis,
JoEtta M Juenke, and Paul I Brown, and Kamisha L Johnson-Davis, and Gwendolyn A McMillin
March 2017, Legal medicine (Tokyo, Japan),
JoEtta M Juenke, and Paul I Brown, and Kamisha L Johnson-Davis, and Gwendolyn A McMillin
December 2014, Puerto Rico health sciences journal,
JoEtta M Juenke, and Paul I Brown, and Kamisha L Johnson-Davis, and Gwendolyn A McMillin
August 2011, Analytical and bioanalytical chemistry,
JoEtta M Juenke, and Paul I Brown, and Kamisha L Johnson-Davis, and Gwendolyn A McMillin
March 2019, Translational and clinical pharmacology,
JoEtta M Juenke, and Paul I Brown, and Kamisha L Johnson-Davis, and Gwendolyn A McMillin
February 2016, Biomedical chromatography : BMC,
JoEtta M Juenke, and Paul I Brown, and Kamisha L Johnson-Davis, and Gwendolyn A McMillin
January 2014, PloS one,
JoEtta M Juenke, and Paul I Brown, and Kamisha L Johnson-Davis, and Gwendolyn A McMillin
January 2017, Methods in molecular biology (Clifton, N.J.),
JoEtta M Juenke, and Paul I Brown, and Kamisha L Johnson-Davis, and Gwendolyn A McMillin
May 2016, Phytochemical analysis : PCA,
Copied contents to your clipboard!