Limb venous compliance responses to lower body negative pressure in humans with high blood pressure. 2012

S Goulopoulou, and K C Deruisseau, and R Carhart, and J A Kanaley
Department of Exercise Science, Syracuse University, Syracuse, NY, USA.

This study tested the hypothesis that limb venous responses to baroreceptor unloading are altered in individuals with high blood pressure (HBP) compared with normotensive (NT) controls. Calf venous compliance was assessed in 20 subjects with prehypertension and stage-1 hypertension (mean arterial pressure, MAP: 104±1 mm Hg) and 13 NT controls (MAP: 86±2 mm Hg) at baseline and during lower body negative pressure (LBNP), using venous occlusion plethysmography. Baroreflex sensitivity (BRS) was measured using the sequence technique and total peripheral resistance (TPR) was estimated from finger plethysmography. Baseline venous compliance was not different between groups, but the HBP group had lower baseline lnBRS (2.22±0.14 vs 2.7±0.18 ms mm Hg(-1)) and greater baseline TPR (3828±138 vs 3250±111 dyn sec(-1) cm(-5) m(2), P<0.05). Calf venous compliance was reduced in response to LBNP only in the NT group (P<0.05). The HBP group had a greater increase in TPR (ΔTPR) compared with the NT group (+1649±335 vs +718±196 dyn sec(-1) cm(-5) m(2), P<0.05). In conclusion, the early stages of hypertension are characterized by an attenuated venoconstrictor response to baroreceptor unloading, which may compensate for an exaggerated vasoconstrictor response and protect against further increases in blood pressure.

UI MeSH Term Description Entries
D006973 Hypertension Persistently high systemic arterial BLOOD PRESSURE. Based on multiple readings (BLOOD PRESSURE DETERMINATION), hypertension is currently defined as when SYSTOLIC PRESSURE is consistently greater than 140 mm Hg or when DIASTOLIC PRESSURE is consistently 90 mm Hg or more. Blood Pressure, High,Blood Pressures, High,High Blood Pressure,High Blood Pressures
D008150 Lower Body Negative Pressure External decompression applied to the lower body. It is used to study orthostatic intolerance and the effects of gravitation and acceleration, to produce simulated hemorrhage in physiologic research, to assess cardiovascular function, and to reduce abdominal stress during childbirth. Abdominal Decompression,Decompression, Abdominal,LBNP
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D009518 New York State bounded on the north by Lake Ontario and Canada, on the east by Vermont, Massachusetts, and Connecticut, on the south by the Atlantic Ocean, New Jersey, and Pennsylvania, and on the west by Pennsylvania, Lake Erie, and Canada.
D010991 Plethysmography Recording of change in the size of a part as modified by the circulation in it. Plethysmographies
D011237 Predictive Value of Tests In screening and diagnostic tests, the probability that a person with a positive test is a true positive (i.e., has the disease), is referred to as the predictive value of a positive test; whereas, the predictive value of a negative test is the probability that the person with a negative test does not have the disease. Predictive value is related to the sensitivity and specificity of the test. Negative Predictive Value,Positive Predictive Value,Predictive Value Of Test,Predictive Values Of Tests,Negative Predictive Values,Positive Predictive Values,Predictive Value, Negative,Predictive Value, Positive
D011311 Pressoreceptors Receptors in the vascular system, particularly the aorta and carotid sinus, which are sensitive to stretch of the vessel walls. Baroreceptors,Receptors, Stretch, Arterial,Receptors, Stretch, Vascular,Stretch Receptors, Arterial,Stretch Receptors, Vascular,Arterial Stretch Receptor,Arterial Stretch Receptors,Baroreceptor,Pressoreceptor,Receptor, Arterial Stretch,Receptor, Vascular Stretch,Receptors, Arterial Stretch,Receptors, Vascular Stretch,Stretch Receptor, Arterial,Stretch Receptor, Vascular,Vascular Stretch Receptor,Vascular Stretch Receptors
D001794 Blood Pressure PRESSURE of the BLOOD on the ARTERIES and other BLOOD VESSELS. Systolic Pressure,Diastolic Pressure,Pulse Pressure,Pressure, Blood,Pressure, Diastolic,Pressure, Pulse,Pressure, Systolic,Pressures, Systolic
D003187 Compliance Distensibility measure of a chamber such as the lungs (LUNG COMPLIANCE) or bladder. Compliance is expressed as a change in volume per unit change in pressure.

Related Publications

S Goulopoulou, and K C Deruisseau, and R Carhart, and J A Kanaley
February 1998, Journal of applied physiology (Bethesda, Md. : 1985),
S Goulopoulou, and K C Deruisseau, and R Carhart, and J A Kanaley
October 1990, The American journal of physiology,
S Goulopoulou, and K C Deruisseau, and R Carhart, and J A Kanaley
May 2000, Clinical physiology (Oxford, England),
S Goulopoulou, and K C Deruisseau, and R Carhart, and J A Kanaley
November 1978, Aviation, space, and environmental medicine,
S Goulopoulou, and K C Deruisseau, and R Carhart, and J A Kanaley
June 1997, Journal of applied physiology (Bethesda, Md. : 1985),
S Goulopoulou, and K C Deruisseau, and R Carhart, and J A Kanaley
July 2014, Journal of applied physiology (Bethesda, Md. : 1985),
S Goulopoulou, and K C Deruisseau, and R Carhart, and J A Kanaley
January 1990, Experimental physiology,
S Goulopoulou, and K C Deruisseau, and R Carhart, and J A Kanaley
March 1991, Journal of applied physiology (Bethesda, Md. : 1985),
S Goulopoulou, and K C Deruisseau, and R Carhart, and J A Kanaley
January 2002, Gerontology,
S Goulopoulou, and K C Deruisseau, and R Carhart, and J A Kanaley
June 1993, Journal of applied physiology (Bethesda, Md. : 1985),
Copied contents to your clipboard!