Aerosol penetration through respirator exhalation valves. 1990

P Bellin, and W C Hinds
UCLA Occupational Health Center, Department of Environmental Health Sciences, School of Public Health 90024.

Exhalation valves are a critical component of industrial respirators. They are designed to permit minimal inward leakage of air contaminants during inhalation and provide low resistance during exhalation. Under normal conditions, penetration of aerosol through exhalation valves is minimal. The exhalation valve is, however, a vulnerable component of a respirator and under actual working conditions may become dirty or damaged to the point of causing significant leakage. Aerosol penetration was measured for normal exhalation valves and valves compromised by paint or fine copper wires on the valve seat. Penetration increased with increasing wire diameter. A wire 250 microns in diameter allowed greater than 1% penetration into the mask cavity. Dirt or paint accumulated on the exhalation valve allowed a similar level of penetration. Work rate had little effect on observed penetration. Penetration decreased significantly with increasing aerosol particle size. The amount of material on the valve or valve seat necessary for significant (greater than 0.5%) inward leakage in a half-mask respirator could be readily observed by careful inspection of the exhalation valve and its seat in good lighting conditions.

UI MeSH Term Description Entries
D010316 Particle Size Relating to the size of solids. Particle Sizes,Size, Particle,Sizes, Particle
D012134 Respiratory Protective Devices Respirators to protect individuals from breathing air contaminated with harmful dusts, fogs, fumes, mists, gases, smokes, sprays, or vapors. Gas Masks,Respirators, Air-Purifying,Respirators, Industrial,Industrial Respirators,Air-Purifying Respirator,Air-Purifying Respirators,Device, Respiratory Protective,Devices, Respiratory Protective,Gas Mask,Industrial Respirator,Mask, Gas,Masks, Gas,Protective Device, Respiratory,Protective Devices, Respiratory,Respirator, Air-Purifying,Respirator, Industrial,Respirators, Air Purifying,Respiratory Protective Device
D004868 Equipment Failure Failure of equipment to perform to standard. The failure may be due to defects or improper use. Defects, Equipment,Device Failure,Failure, Equipment,Malfunction, Equipment,Medical Device Failure,Misuse, Equipment,Device Failure, Medical,Device Failures, Medical,Failure, Medical Device,Failures, Medical Device,Defect, Equipment,Device Failures,Equipment Defect,Equipment Defects,Equipment Failures,Equipment Malfunction,Equipment Malfunctions,Equipment Misuse,Equipment Misuses,Failure, Device,Failures, Device,Failures, Equipment,Malfunctions, Equipment,Misuses, Equipment
D005069 Evaluation Studies as Topic Works about studies that determine the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. Critique,Evaluation Indexes,Evaluation Methodology,Evaluation Report,Evaluation Research,Methodology, Evaluation,Pre-Post Tests,Qualitative Evaluation,Quantitative Evaluation,Theoretical Effectiveness,Use-Effectiveness,Critiques,Effectiveness, Theoretical,Evaluation Methodologies,Evaluation Reports,Evaluation, Qualitative,Evaluation, Quantitative,Evaluations, Qualitative,Evaluations, Quantitative,Indexes, Evaluation,Methodologies, Evaluation,Pre Post Tests,Pre-Post Test,Qualitative Evaluations,Quantitative Evaluations,Report, Evaluation,Reports, Evaluation,Research, Evaluation,Test, Pre-Post,Tests, Pre-Post,Use Effectiveness
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000336 Aerosols Colloids with a gaseous dispersing phase and either liquid (fog) or solid (smoke) dispersed phase; used in fumigation or in inhalation therapy; may contain propellant agents. Aerosol
D012212 Rheology The study of the deformation and flow of matter, usually liquids or fluids, and of the plastic flow of solids. The concept covers consistency, dilatancy, liquefaction, resistance to flow, shearing, thixotrophy, and VISCOSITY. Flowmetry,Velocimetry,Velocimetries

Related Publications

P Bellin, and W C Hinds
March 1998, American Industrial Hygiene Association journal,
P Bellin, and W C Hinds
September 1992, American Industrial Hygiene Association journal,
P Bellin, and W C Hinds
July 1998, American Industrial Hygiene Association journal,
P Bellin, and W C Hinds
December 1975, American Industrial Hygiene Association journal,
P Bellin, and W C Hinds
September 1988, American Industrial Hygiene Association journal,
P Bellin, and W C Hinds
January 2001, AIHAJ : a journal for the science of occupational and environmental health and safety,
P Bellin, and W C Hinds
July 1965, Health physics,
P Bellin, and W C Hinds
August 1992, American journal of infection control,
P Bellin, and W C Hinds
November 2006, Journal of occupational and environmental hygiene,
Copied contents to your clipboard!