Monte Carlo calculations for efficiency calibration of a whole-body monitor using BOMAB phantoms of different sizes. 2012

S Bhati, and H K Patni, and V P Ghare, and I S Singh, and M Y Nadar
Health Physics Division, Bhabha Atomic Research Centre, BARC Hospital, Mumbai 400 094, India. sharda.bhati@gmail.com

Internal contamination due to high-energy photon (HEP) emitters is assessed using a scanning bed whole-body monitor housed in a steel room at the Bhabha Atomic Research Centre (BARC). The monitor consists of a (203 mm diameter × 102 mm thickness) NaI(Tl) detector and is calibrated using a Reference BOMAB phantom representative of an average Indian radiation worker. However, a series of different size physical phantoms are required to account for size variability in workers, which is both expensive and time consuming. Therefore, a theoretical approach based on Monte Carlo techniques has been employed to calibrate the system in scanning geometry with BOMAB phantoms of different sizes characterised by their weight (W) and height (H) for several radionuclides of interest ((131)I, (137)Cs, (60)Co and (40)K). A computer program developed for this purpose generates the detector response and the detection efficiencies (DEs) for the BARC Reference phantom (63 kg/168 cm), ICRP Reference male phantom (70 kg/170 cm) and several of its scaled versions. The results obtained for different size phantoms indicated a decreasing trend of DEs with the increase in W/H values of the phantoms. The computed DEs for uniform distribution of (137)Cs in BOMAB phantom varied from 3.52 × 10(-3) to 2.88 × 10(-3) counts per photon as the W/H values increased from 0.26 to 0.50. The theoretical results obtained for the BARC Reference phantom have been verified with experimental measurements. The Monte Carlo results from this study will be useful for in vivo assessment of HEP emitters in radiation workers of different physiques.

UI MeSH Term Description Entries
D007194 India A country in southern Asia, bordering the Arabian Sea and the Bay of Bengal, between Burma and Pakistan. The capitol is New Delhi. Republic of India
D008297 Male Males
D009010 Monte Carlo Method In statistics, a technique for numerically approximating the solution of a mathematical problem by studying the distribution of some random variable, often generated by a computer. The name alludes to the randomness characteristic of the games of chance played at the gambling casinos in Monte Carlo. (From Random House Unabridged Dictionary, 2d ed, 1993) Method, Monte Carlo
D010315 Particle Accelerators Devices which accelerate electrically charged atomic or subatomic particles, such as electrons, protons or ions, to high velocities so they have high kinetic energy. Betatrons,Linear Accelerators,Accelerator, Linear,Accelerator, Particle,Accelerators, Linear,Accelerators, Particle,Betatron,Linear Accelerator,Particle Accelerator
D011834 Radiation Monitoring The observation, either continuously or at intervals, of the levels of radiation in a given area, generally for the purpose of assuring that they have not exceeded prescribed amounts or, in case of radiation already present in the area, assuring that the levels have returned to those meeting acceptable safety standards. Monitoring, Radiation
D011874 Radiometry The measurement of radiation by photography, as in x-ray film and film badge, by Geiger-Mueller tube, and by SCINTILLATION COUNTING. Geiger-Mueller Counters,Nuclear Track Detection,Radiation Dosimetry,Dosimetry, Radiation,Geiger Counter,Geiger-Mueller Counter Tube,Geiger-Mueller Probe,Geiger-Mueller Tube,Radiation Counter,Counter Tube, Geiger-Mueller,Counter Tubes, Geiger-Mueller,Counter, Geiger,Counter, Radiation,Counters, Geiger,Counters, Geiger-Mueller,Counters, Radiation,Detection, Nuclear Track,Dosimetries, Radiation,Geiger Counters,Geiger Mueller Counter Tube,Geiger Mueller Counters,Geiger Mueller Probe,Geiger Mueller Tube,Geiger-Mueller Counter Tubes,Geiger-Mueller Probes,Geiger-Mueller Tubes,Probe, Geiger-Mueller,Probes, Geiger-Mueller,Radiation Counters,Radiation Dosimetries,Tube, Geiger-Mueller,Tube, Geiger-Mueller Counter,Tubes, Geiger-Mueller,Tubes, Geiger-Mueller Counter
D012016 Reference Values The range or frequency distribution of a measurement in a population (of organisms, organs or things) that has not been selected for the presence of disease or abnormality. Normal Range,Normal Values,Reference Ranges,Normal Ranges,Normal Value,Range, Normal,Range, Reference,Ranges, Normal,Ranges, Reference,Reference Range,Reference Value,Value, Normal,Value, Reference,Values, Normal,Values, Reference
D001827 Body Height The distance from the sole to the crown of the head with body standing on a flat surface and fully extended. Body Heights,Height, Body,Heights, Body
D001835 Body Weight The mass or quantity of heaviness of an individual. It is expressed by units of pounds or kilograms. Body Weights,Weight, Body,Weights, Body
D002138 Calibration Determination, by measurement or comparison with a standard, of the correct value of each scale reading on a meter or other measuring instrument; or determination of the settings of a control device that correspond to particular values of voltage, current, frequency or other output. Calibrations

Related Publications

S Bhati, and H K Patni, and V P Ghare, and I S Singh, and M Y Nadar
April 2023, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine,
S Bhati, and H K Patni, and V P Ghare, and I S Singh, and M Y Nadar
March 2015, Radiation protection dosimetry,
S Bhati, and H K Patni, and V P Ghare, and I S Singh, and M Y Nadar
April 2015, Radiation protection dosimetry,
S Bhati, and H K Patni, and V P Ghare, and I S Singh, and M Y Nadar
October 2008, Physics in medicine and biology,
S Bhati, and H K Patni, and V P Ghare, and I S Singh, and M Y Nadar
March 2012, Radiation protection dosimetry,
S Bhati, and H K Patni, and V P Ghare, and I S Singh, and M Y Nadar
December 2014, Radiation protection dosimetry,
S Bhati, and H K Patni, and V P Ghare, and I S Singh, and M Y Nadar
January 2007, Radiation protection dosimetry,
S Bhati, and H K Patni, and V P Ghare, and I S Singh, and M Y Nadar
January 2004, Zeitschrift fur medizinische Physik,
S Bhati, and H K Patni, and V P Ghare, and I S Singh, and M Y Nadar
October 2002, Health physics,
S Bhati, and H K Patni, and V P Ghare, and I S Singh, and M Y Nadar
June 2019, Journal of applied clinical medical physics,
Copied contents to your clipboard!