[A comparison of digital luminescence radiography and the conventional film-screen technic in pulmonary coin lesions--a clinical study]. 1990

B Schwermer, and G Witte, and R P Spielmann, and V Nicolas, and T Fassbender
Röntgendiagnostische Abteilung, Radiologische Klinik, Universitätskrankenhaus Hamburg-Eppendorf.

The aim of this investigation is the evaluation of DLR for the radiological diagnosis of intrapulmonary coin lesions. For this, a DLR system was used which had been specially developed for chest radiography. Early results were unsatisfactory and therefore specific image parameters were developed. The scope for dose reduction was also investigated. Oncology patients were examined by DLR and by our reference system. Results show that DLR is better than conventional images if edge enhancement is carried out, using the specific parameters. The superiority of the optimised digital images is apparent particularly in those portions of the lung that are obscured by the cardiac or diaphragmatic shadows. Because of image noise, a dose reduction of only 28% is possible, compared with our reference system.

UI MeSH Term Description Entries
D008163 Luminescent Measurements Techniques used for determining the values of photometric parameters of light resulting from LUMINESCENCE. Bioluminescence Measurements,Bioluminescent Assays,Bioluminescent Measurements,Chemiluminescence Measurements,Chemiluminescent Assays,Chemiluminescent Measurements,Chemoluminescence Measurements,Luminescence Measurements,Luminescent Assays,Luminescent Techniques,Phosphorescence Measurements,Phosphorescent Assays,Phosphorescent Measurements,Assay, Bioluminescent,Assay, Chemiluminescent,Assay, Luminescent,Assay, Phosphorescent,Assays, Bioluminescent,Assays, Chemiluminescent,Assays, Luminescent,Assays, Phosphorescent,Bioluminescence Measurement,Bioluminescent Assay,Bioluminescent Measurement,Chemiluminescence Measurement,Chemiluminescent Assay,Chemiluminescent Measurement,Chemoluminescence Measurement,Luminescence Measurement,Luminescent Assay,Luminescent Measurement,Luminescent Technique,Measurement, Bioluminescence,Measurement, Bioluminescent,Measurement, Chemiluminescence,Measurement, Chemiluminescent,Measurement, Chemoluminescence,Measurement, Luminescence,Measurement, Luminescent,Measurement, Phosphorescence,Measurement, Phosphorescent,Measurements, Bioluminescence,Measurements, Bioluminescent,Measurements, Chemiluminescence,Measurements, Chemiluminescent,Measurements, Chemoluminescence,Measurements, Luminescence,Measurements, Luminescent,Measurements, Phosphorescence,Measurements, Phosphorescent,Phosphorescence Measurement,Phosphorescent Assay,Phosphorescent Measurement,Technique, Luminescent,Techniques, Luminescent
D008168 Lung Either of the pair of organs occupying the cavity of the thorax that effect the aeration of the blood. Lungs
D008175 Lung Neoplasms Tumors or cancer of the LUNG. Cancer of Lung,Lung Cancer,Pulmonary Cancer,Pulmonary Neoplasms,Cancer of the Lung,Neoplasms, Lung,Neoplasms, Pulmonary,Cancer, Lung,Cancer, Pulmonary,Cancers, Lung,Cancers, Pulmonary,Lung Cancers,Lung Neoplasm,Neoplasm, Lung,Neoplasm, Pulmonary,Pulmonary Cancers,Pulmonary Neoplasm
D011829 Radiation Dosage The amount of radiation energy that is deposited in a unit mass of material, such as tissues of plants or animal. In RADIOTHERAPY, radiation dosage is expressed in gray units (Gy). In RADIOLOGIC HEALTH, the dosage is expressed by the product of absorbed dose (Gy) and quality factor (a function of linear energy transfer), and is called radiation dose equivalent in sievert units (Sv). Sievert Units,Dosage, Radiation,Gray Units,Gy Radiation,Sv Radiation Dose Equivalent,Dosages, Radiation,Radiation Dosages,Units, Gray,Units, Sievert
D011856 Radiographic Image Enhancement Improvement in the quality of an x-ray image by use of an intensifying screen, tube, or filter and by optimum exposure techniques. Digital processing methods are often employed. Digital Radiography,Image Enhancement, Radiographic,Radiography, Digital,Enhancement, Radiographic Image,Enhancements, Radiographic Image,Image Enhancements, Radiographic,Radiographic Image Enhancements
D003074 Solitary Pulmonary Nodule A single lung lesion that is characterized by a small round mass of tissue, usually less than 1 cm in diameter, and can be detected by chest radiography. A solitary pulmonary nodule can be associated with neoplasm, tuberculosis, cyst, or other anomalies in the lung, the CHEST WALL, or the PLEURA. Coin Lesion, Pulmonary,Pulmonary Coin Lesion,Pulmonary Nodule, Solitary,Solitary Lung Nodule,Coin Lesions, Pulmonary,Nodule, Solitary Pulmonary,Nodules, Solitary Pulmonary,Pulmonary Coin Lesions,Pulmonary Nodules, Solitary,Solitary Pulmonary Nodules,Lesion, Pulmonary Coin,Lung Nodule, Solitary,Nodule, Solitary Lung,Solitary Lung Nodules
D005069 Evaluation Studies as Topic Works about studies that determine the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. Critique,Evaluation Indexes,Evaluation Methodology,Evaluation Report,Evaluation Research,Methodology, Evaluation,Pre-Post Tests,Qualitative Evaluation,Quantitative Evaluation,Theoretical Effectiveness,Use-Effectiveness,Critiques,Effectiveness, Theoretical,Evaluation Methodologies,Evaluation Reports,Evaluation, Qualitative,Evaluation, Quantitative,Evaluations, Qualitative,Evaluations, Quantitative,Indexes, Evaluation,Methodologies, Evaluation,Pre Post Tests,Pre-Post Test,Qualitative Evaluations,Quantitative Evaluations,Report, Evaluation,Reports, Evaluation,Research, Evaluation,Test, Pre-Post,Tests, Pre-Post,Use Effectiveness
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D014963 X-Ray Intensifying Screens Screens which absorb the energy in the x-ray beam that has penetrated the patient and convert this energy into a light pattern which has as nearly as possible the same information as the original x-ray beam. The more light a screen produces for a given input of x-radiation, the less x-ray exposure and thus shorter exposure time are needed to expose the film. In most film-screen systems, the film is sandwiched between two screens in a cassette so that the emulsion on each side is exposed to the light from its contiguous screen. Film-Screen Systems, X-Ray,Radiographic Intensifying Screens,Screen-Film Systems, X-Ray,X-Ray Film-Screen Systems,Screens, Radiographic Intensifying,Xray Intensifying Screens,Film Screen Systems, X Ray,Film-Screen System, X-Ray,Intensifying Screen, Radiographic,Intensifying Screen, X-Ray,Intensifying Screen, Xray,Intensifying Screens, Radiographic,Intensifying Screens, X-Ray,Intensifying Screens, Xray,Radiographic Intensifying Screen,Screen Film Systems, X Ray,Screen, Radiographic Intensifying,Screen, X-Ray Intensifying,Screen, Xray Intensifying,Screen-Film System, X-Ray,Screens, X-Ray Intensifying,Screens, Xray Intensifying,System, X-Ray Film-Screen,System, X-Ray Screen-Film,Systems, X-Ray Film-Screen,Systems, X-Ray Screen-Film,X Ray Film Screen Systems,X Ray Intensifying Screens,X-Ray Film-Screen System,X-Ray Intensifying Screen,X-Ray Screen-Film System,X-Ray Screen-Film Systems,Xray Intensifying Screen

Related Publications

B Schwermer, and G Witte, and R P Spielmann, and V Nicolas, and T Fassbender
April 1996, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin,
B Schwermer, and G Witte, and R P Spielmann, and V Nicolas, and T Fassbender
October 1996, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin,
B Schwermer, and G Witte, and R P Spielmann, and V Nicolas, and T Fassbender
April 1990, Rontgen-Blatter; Zeitschrift fur Rontgen-Technik und medizinisch-wissenschaftliche Photographie,
B Schwermer, and G Witte, and R P Spielmann, and V Nicolas, and T Fassbender
March 1998, European journal of medical research,
B Schwermer, and G Witte, and R P Spielmann, and V Nicolas, and T Fassbender
January 1999, AJR. American journal of roentgenology,
B Schwermer, and G Witte, and R P Spielmann, and V Nicolas, and T Fassbender
December 2001, AJR. American journal of roentgenology,
B Schwermer, and G Witte, and R P Spielmann, and V Nicolas, and T Fassbender
January 1995, La Radiologia medica,
B Schwermer, and G Witte, and R P Spielmann, and V Nicolas, and T Fassbender
March 1991, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin,
B Schwermer, and G Witte, and R P Spielmann, and V Nicolas, and T Fassbender
January 1984, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin,
B Schwermer, and G Witte, and R P Spielmann, and V Nicolas, and T Fassbender
January 1985, Radiography,
Copied contents to your clipboard!