A real-time adaptive ultrasonic imaging system. 1990

G E Trahey, and D Zhao, and P D Freiburger, and B A Carroll
Department of Biomedical Engineering, Duke University, Durham, North Carolina 27706.

The performance of an experimental, adaptive, phased array imaging system in improving the quality of abdominal organ images in healthy volunteers was assessed. Trials were conducted under usual clinical imaging conditions and when phase aberrators of known shape and magnitude were introduced into the imaging system. The system, which uses local target brightness as a quality factor, was able to improve clinical image quality when aberrators introduced externally were present and had a negligible effect on image quality when they were not. On several of the volunteers, the phase aberrations were measured directly across the abdomen. The implications of these results for the future clinical application of adaptive imaging systems and the future system modifications are reported.

UI MeSH Term Description Entries
D007668 Kidney Body organ that filters blood for the secretion of URINE and that regulates ion concentrations. Kidneys
D008099 Liver A large lobed glandular organ in the abdomen of vertebrates that is responsible for detoxification, metabolism, synthesis and storage of various substances. Livers
D008297 Male Males
D012016 Reference Values The range or frequency distribution of a measurement in a population (of organisms, organs or things) that has not been selected for the presence of disease or abnormality. Normal Range,Normal Values,Reference Ranges,Normal Ranges,Normal Value,Range, Normal,Range, Reference,Ranges, Normal,Ranges, Reference,Reference Range,Reference Value,Value, Normal,Value, Reference,Values, Normal,Values, Reference
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000328 Adult A person having attained full growth or maturity. Adults are of 19 through 44 years of age. For a person between 19 and 24 years of age, YOUNG ADULT is available. Adults
D014463 Ultrasonography The visualization of deep structures of the body by recording the reflections or echoes of ultrasonic pulses directed into the tissues. Use of ultrasound for imaging or diagnostic purposes employs frequencies ranging from 1.6 to 10 megahertz. Echography,Echotomography,Echotomography, Computer,Sonography, Medical,Tomography, Ultrasonic,Ultrasonic Diagnosis,Ultrasonic Imaging,Ultrasonographic Imaging,Computer Echotomography,Diagnosis, Ultrasonic,Diagnostic Ultrasound,Ultrasonic Tomography,Ultrasound Imaging,Diagnoses, Ultrasonic,Diagnostic Ultrasounds,Imaging, Ultrasonic,Imaging, Ultrasonographic,Imaging, Ultrasound,Imagings, Ultrasonographic,Imagings, Ultrasound,Medical Sonography,Ultrasonic Diagnoses,Ultrasonographic Imagings,Ultrasound, Diagnostic,Ultrasounds, Diagnostic

Related Publications

G E Trahey, and D Zhao, and P D Freiburger, and B A Carroll
January 1977, Ultrasound in medicine & biology,
G E Trahey, and D Zhao, and P D Freiburger, and B A Carroll
January 1988, IEEE transactions on ultrasonics, ferroelectrics, and frequency control,
G E Trahey, and D Zhao, and P D Freiburger, and B A Carroll
August 1978, Journal of clinical ultrasound : JCU,
G E Trahey, and D Zhao, and P D Freiburger, and B A Carroll
April 1983, Medical electronics,
G E Trahey, and D Zhao, and P D Freiburger, and B A Carroll
January 1992, Ultrasound in medicine & biology,
G E Trahey, and D Zhao, and P D Freiburger, and B A Carroll
February 2024, Optics letters,
G E Trahey, and D Zhao, and P D Freiburger, and B A Carroll
January 1989, International journal of cardiac imaging,
G E Trahey, and D Zhao, and P D Freiburger, and B A Carroll
September 1981, The British journal of radiology,
G E Trahey, and D Zhao, and P D Freiburger, and B A Carroll
November 2003, Journal of magnetic resonance imaging : JMRI,
G E Trahey, and D Zhao, and P D Freiburger, and B A Carroll
June 2021, Medical & biological engineering & computing,
Copied contents to your clipboard!