Accuracy of four indirect methods of blood pressure measurement, with hemodynamic correlations. 1990

G P Gravlee, and J K Brockschmidt
Department of Anesthesia, Bowman Gray School of Medicine, Wake Forest University, Winston-Salem, NC 27103.

In 38 adults undergoing cardiac surgery, 4 indirect blood pressure techniques were compared with brachial arterial blood pressure at predetermined intervals before and after cardiopulmonary bypass. Indirect blood pressure measurement techniques included automated oscillometry, manual auscultation, visual onset of oscillation (flicker) and return-to-flow methods. Hemodynamic measurements or calculations included heart rate, cardiac index, stroke volume index, and systemic vascular resistance index. Indirect and intraarterial blood pressure values were compared by simple linear regression by patient and measurement period. Measurement errors (arterial minus indirect blood pressure) were calculated, and stepwise regression assessed the relationship between measurement error and heart rate, cardiac index, stroke volume index, and systemic vascular resistance index. Indirect to intraarterial blood pressure correlation coefficients varied over time, with the strongest correlations often occurring at the first and last measurement periods (preinduction and 60 minutes after cardiopulmonary bypass), particularly for systolic blood pressure. Within-patient correlations between indirect and arterial blood pressure varied widely--they were consistently high or low in some patients. In other patients, correlations were especially weak with a particular indirect blood pressure method for systolic, mean, or diastolic blood pressure; in some cases indirect blood pressure was inadequate for clinical diagnosis of acute blood pressure changes or trends. The mean correlations between indirect and direct blood pressure values were, for systolic blood pressure: 0.69 for oscillometry, 0.77 for auscultation, 0.73 for flicker, and 0.74 for return-to-flow; for mean blood pressure: 0.70 for oscillometry and 0.73 for auscultation; and for diastolic blood pressure: 0.73 for oscillometry and 0.69 for auscultation. The mean measurement errors (arterial minus indirect values) for the individual indirect blood pressure methods were, for systolic: 0 mm Hg for oscillometry, 9 mm Hg for auscultation, -5 mm Hg for flicker, 7 mm Hg for return-to-flow; for mean: -6 mm Hg for oscillometry, and -3 mm Hg for auscultation; and for diastolic: -9 mm Hg for oscillometry and -8 mm Hg for auscultation. Mean measurement error for systolic blood pressure was thus least with automated oscillometry and greatest with manual auscultation, while standard deviations ranging from 9 to 15 mm Hg confirmed the highly variable nature of single indirect blood pressure measurements. Except for oscillometric diastolic blood pressure, a combination of systemic hemodynamics (heart rate, stroke volume index, systemic vascular resistance index, and cardiac index) correlated with each indirect blood pressure measurement error, which suggests that particular numeric ranges of these variables minimize measurement error.(ABSTRACT TRUNCATED AT 400 WORDS)

UI MeSH Term Description Entries
D008297 Male Males
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D009991 Oscillometry The measurement of frequency or oscillation changes. Oscillometries
D001794 Blood Pressure PRESSURE of the BLOOD on the ARTERIES and other BLOOD VESSELS. Systolic Pressure,Diastolic Pressure,Pulse Pressure,Pressure, Blood,Pressure, Diastolic,Pressure, Pulse,Pressure, Systolic,Pressures, Systolic
D001795 Blood Pressure Determination Techniques used for measuring BLOOD PRESSURE. Blood Pressure Determinations,Determination, Blood Pressure
D001916 Brachial Artery The continuation of the axillary artery; it branches into the radial and ulnar arteries. Arteries, Brachial,Artery, Brachial,Brachial Arteries
D002302 Cardiac Output The volume of BLOOD passing through the HEART per unit of time. It is usually expressed as liters (volume) per minute so as not to be confused with STROKE VOLUME (volume per beat). Cardiac Outputs,Output, Cardiac,Outputs, Cardiac
D002406 Catheterization, Peripheral Insertion of a catheter into a peripheral artery, vein, or airway for diagnostic or therapeutic purposes. Arterial Catheterization, Peripheral,Catheterization, Bronchial,Catheterization, Peripheral Arterial,Catheterization, Peripheral Venous,Peripheral Catheterization,Venous Catheterization, Peripheral,Bronchial Catheterization,PICC Line Catheterization,PICC Line Placement,PICC Placement,Peripheral Arterial Catheterization,Peripheral Venous Catheterization,Peripherally Inserted Central Catheter Line Insertion,Arterial Catheterizations, Peripheral,Bronchial Catheterizations,Catheterization, PICC Line,Catheterizations, Bronchial,Catheterizations, PICC Line,Catheterizations, Peripheral,Catheterizations, Peripheral Arterial,Catheterizations, Peripheral Venous,PICC Line Catheterizations,PICC Line Placements,PICC Placements,Peripheral Arterial Catheterizations,Peripheral Catheterizations,Peripheral Venous Catheterizations,Placement, PICC,Placement, PICC Line,Placements, PICC,Placements, PICC Line,Venous Catheterizations, Peripheral
D005260 Female Females
D006339 Heart Rate The number of times the HEART VENTRICLES contract per unit of time, usually per minute. Cardiac Rate,Chronotropism, Cardiac,Heart Rate Control,Heartbeat,Pulse Rate,Cardiac Chronotropy,Cardiac Chronotropism,Cardiac Rates,Chronotropy, Cardiac,Control, Heart Rate,Heart Rates,Heartbeats,Pulse Rates,Rate Control, Heart,Rate, Cardiac,Rate, Heart,Rate, Pulse

Related Publications

G P Gravlee, and J K Brockschmidt
February 1978, Pediatric clinics of North America,
G P Gravlee, and J K Brockschmidt
January 1973, Anesthesia and analgesia,
G P Gravlee, and J K Brockschmidt
October 1965, Proceedings of the Royal Society of Medicine,
G P Gravlee, and J K Brockschmidt
May 1983, British medical journal (Clinical research ed.),
G P Gravlee, and J K Brockschmidt
January 2005, Journal of veterinary internal medicine,
G P Gravlee, and J K Brockschmidt
January 1993, American journal of hypertension,
G P Gravlee, and J K Brockschmidt
June 1989, Pediatria polska,
G P Gravlee, and J K Brockschmidt
September 1990, Intensive care nursing,
G P Gravlee, and J K Brockschmidt
September 1979, Wiadomosci lekarskie (Warsaw, Poland : 1960),
Copied contents to your clipboard!