Effect of duration of ventricular fibrillation on defibrillation efficacy in humans. 1990

R A Winkle, and R H Mead, and M A Ruder, and N A Smith, and W S Buch, and V A Gaudiani
Cardiovascular Section, Sequoia Hospital, Redwood City, California.

The currently available automatic implantable cardioverter-defibrillator has proven highly successful for termination of ventricular tachycardia and fibrillation. Newer devices, however, permit lower energy shocks to be delivered initially and longer episodes of arrhythmia to occur before shocks are delivered. These changes may result in longer durations of arrhythmia before successful termination. Little is known about the effects of the duration of ventricular fibrillation on the efficacy of defibrillating shocks. In this study, we examined the efficacy of defibrillating shocks in 22 patients undergoing automatic implantable cardioverter-defibrillator implantation or generator change. Defibrillating shocks ranging from 300 to 600 V (5.9-24.2 J) were delivered in matched pairs after 5 and 15 seconds of ventricular fibrillation. For the 300-V shocks (5.9 J), defibrillation was accomplished in 82% of patients when the shocks were given after 5 seconds of ventricular fibrillation and in only 45% of patients when the shocks were delivered after 15 seconds (p less than 0.01). At higher energies, there was no difference in the efficacy of defibrillation shocks delivered after 5 compared with 15 seconds of ventricular fibrillation. The postshock aortic, systolic, and diastolic blood pressures were significantly lower when the shocks were given after 15 seconds of ventricular fibrillation than after only 5 seconds. We conclude that the duration of ventricular fibrillation affects defibrillation efficacy especially at energies that are relatively low compared with maximal device outputs and that longer episodes of ventricular fibrillation cause more postshock hemodynamic depression. These observations have implications for defibrillation threshold testing at the time of device implantation and for the design and programming of future automatic implantable antitachycardia devices.

UI MeSH Term Description Entries
D008875 Middle Aged An adult aged 45 - 64 years. Middle Age
D001794 Blood Pressure PRESSURE of the BLOOD on the ARTERIES and other BLOOD VESSELS. Systolic Pressure,Diastolic Pressure,Pulse Pressure,Pressure, Blood,Pressure, Diastolic,Pressure, Pulse,Pressure, Systolic,Pressures, Systolic
D004554 Electric Countershock An electrical current applied to the HEART to terminate a CARDIAC ARRHYTHMIA. Cardiac Electroversion,Cardioversion,Defibrillation, Electric,Electroversion, Cardiac,Electrical Cardioversion,Electroversion Therapy,Therapy, Electroversion,Cardiac Electroversions,Cardioversion, Electrical,Cardioversions,Cardioversions, Electrical,Countershock, Electric,Countershocks, Electric,Defibrillations, Electric,Electric Countershocks,Electric Defibrillation,Electric Defibrillations,Electrical Cardioversions,Electroversion Therapies,Electroversions, Cardiac,Therapies, Electroversion
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000328 Adult A person having attained full growth or maturity. Adults are of 19 through 44 years of age. For a person between 19 and 24 years of age, YOUNG ADULT is available. Adults
D000368 Aged A person 65 years of age or older. For a person older than 79 years, AGED, 80 AND OVER is available. Elderly
D013318 Stroke Volume The amount of BLOOD pumped out of the HEART per beat, not to be confused with cardiac output (volume/time). It is calculated as the difference between the end-diastolic volume and the end-systolic volume. Ventricular Ejection Fraction,Ventricular End-Diastolic Volume,Ventricular End-Systolic Volume,Ejection Fraction, Ventricular,Ejection Fractions, Ventricular,End-Diastolic Volume, Ventricular,End-Diastolic Volumes, Ventricular,End-Systolic Volume, Ventricular,End-Systolic Volumes, Ventricular,Fraction, Ventricular Ejection,Fractions, Ventricular Ejection,Stroke Volumes,Ventricular Ejection Fractions,Ventricular End Diastolic Volume,Ventricular End Systolic Volume,Ventricular End-Diastolic Volumes,Ventricular End-Systolic Volumes,Volume, Stroke,Volume, Ventricular End-Diastolic,Volume, Ventricular End-Systolic,Volumes, Stroke,Volumes, Ventricular End-Diastolic,Volumes, Ventricular End-Systolic
D013997 Time Factors Elements of limited time intervals, contributing to particular results or situations. Time Series,Factor, Time,Time Factor
D014693 Ventricular Fibrillation A potentially lethal cardiac arrhythmia that is characterized by uncoordinated extremely rapid firing of electrical impulses (400-600/min) in HEART VENTRICLES. Such asynchronous ventricular quivering or fibrillation prevents any effective cardiac output and results in unconsciousness (SYNCOPE). It is one of the major electrocardiographic patterns seen with CARDIAC ARREST. Fibrillation, Ventricular,Fibrillations, Ventricular,Ventricular Fibrillations
D019736 Prostheses and Implants Artificial substitutes for body parts, and materials inserted into tissue for functional, cosmetic, or therapeutic purposes. Prostheses can be functional, as in the case of artificial arms and legs, or cosmetic, as in the case of an artificial eye. Implants, all surgically inserted or grafted into the body, tend to be used therapeutically. IMPLANTS, EXPERIMENTAL is available for those used experimentally. Implants, Artificial,Prostheses and Implant,Prosthesis,Prosthetic Implant,Endoprostheses,Endoprosthesis,Prostheses,Prosthetic Implants,Artificial Implant,Artificial Implants,Implant and Prostheses,Implant, Artificial,Implant, Prosthetic,Implants and Prostheses,Implants, Prosthetic

Related Publications

R A Winkle, and R H Mead, and M A Ruder, and N A Smith, and W S Buch, and V A Gaudiani
January 2002, Pacing and clinical electrophysiology : PACE,
R A Winkle, and R H Mead, and M A Ruder, and N A Smith, and W S Buch, and V A Gaudiani
January 1999, Journal of the American College of Cardiology,
R A Winkle, and R H Mead, and M A Ruder, and N A Smith, and W S Buch, and V A Gaudiani
May 1989, Journal of the American College of Cardiology,
R A Winkle, and R H Mead, and M A Ruder, and N A Smith, and W S Buch, and V A Gaudiani
August 1993, The American journal of cardiology,
R A Winkle, and R H Mead, and M A Ruder, and N A Smith, and W S Buch, and V A Gaudiani
March 2008, The American journal of emergency medicine,
R A Winkle, and R H Mead, and M A Ruder, and N A Smith, and W S Buch, and V A Gaudiani
July 1985, The American journal of emergency medicine,
R A Winkle, and R H Mead, and M A Ruder, and N A Smith, and W S Buch, and V A Gaudiani
August 1998, Journal of the American College of Cardiology,
R A Winkle, and R H Mead, and M A Ruder, and N A Smith, and W S Buch, and V A Gaudiani
March 1997, Journal of the American College of Cardiology,
R A Winkle, and R H Mead, and M A Ruder, and N A Smith, and W S Buch, and V A Gaudiani
January 1995, Journal of electrocardiology,
R A Winkle, and R H Mead, and M A Ruder, and N A Smith, and W S Buch, and V A Gaudiani
September 1988, Pacing and clinical electrophysiology : PACE,
Copied contents to your clipboard!