In-office microwave disinfection of soft contact lenses. 1990

M G Harris, and J Rechberger, and T Grant, and B A Holden
Morton D. Sarver Laboratory for Contact Lens and Corneal Research, University of California School of Optometry, Berkeley.

We evaluated the effectiveness of an in-office microwave disinfection procedure which allowed for the disinfection of up to 40 soft contact lenses at one time. Ciba AOSept cases filled with sterile unpreserved saline were contaminated with one of six FDA test challenge microorganisms at a concentration of approximately 10(3) colony forming units per milliliter (CFU/ml). Twenty cases were placed on the rotating plate of a standard 2450 MHz 650 W microwave oven in a 10-cm diameter circle. The cases were exposed to high intensity microwave irradiation for periods of 0 to 15 min. None of the 6 microorganisms evaluated survived 2 min or longer of microwave exposure. Our findings indicated that microwave irradiation can be a convenient, rapid, and effective method of disinfecting a number of soft contact lenses at one time and thus adaptable as an in-office soft contact lens disinfection procedure.

UI MeSH Term Description Entries
D008872 Microwaves That portion of the electromagnetic spectrum from the UHF (ultrahigh frequency) radio waves and extending into the INFRARED RAYS frequencies. EHF Waves,Extremely High Frequency Radio Waves,Micro Wave,Micro Waves,Ultrahigh Frequency Waves,Microwave Radiation,EHF Wave,Micro Waves,Microwave,Microwave Radiations,Radiation, Microwave,Ultrahigh Frequency Wave,Wave, EHF,Wave, Micro,Wave, Ultrahigh Frequency,Waves, Micro
D003263 Contact Lenses, Hydrophilic Soft, supple contact lenses made of plastic polymers which interact readily with water molecules. Many types are available, including continuous and extended-wear versions, which are gas-permeable and easily sterilized. Lenses, Contact, Hydrophilic,Soft Contact Lenses,Hydrophilic Contact Lens,Soft Contact Lens,Contact Lens, Hydrophilic,Contact Lens, Soft,Contact Lenses, Soft,Hydrophilic Contact Lenses,Lens, Hydrophilic Contact,Lens, Soft Contact,Lenses, Hydrophilic Contact,Lenses, Soft Contact
D004203 Disinfection Rendering pathogens harmless through the use of heat, antiseptics, antibacterial agents, etc.
D005069 Evaluation Studies as Topic Works about studies that determine the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. Critique,Evaluation Indexes,Evaluation Methodology,Evaluation Report,Evaluation Research,Methodology, Evaluation,Pre-Post Tests,Qualitative Evaluation,Quantitative Evaluation,Theoretical Effectiveness,Use-Effectiveness,Critiques,Effectiveness, Theoretical,Evaluation Methodologies,Evaluation Reports,Evaluation, Qualitative,Evaluation, Quantitative,Evaluations, Qualitative,Evaluations, Quantitative,Indexes, Evaluation,Methodologies, Evaluation,Pre Post Tests,Pre-Post Test,Qualitative Evaluations,Quantitative Evaluations,Report, Evaluation,Reports, Evaluation,Research, Evaluation,Test, Pre-Post,Tests, Pre-Post,Use Effectiveness
D005658 Fungi A kingdom of eukaryotic, heterotrophic organisms that live parasitically as saprobes, including MUSHROOMS; YEASTS; smuts, molds, etc. They reproduce either sexually or asexually, and have life cycles that range from simple to complex. Filamentous fungi, commonly known as molds, refer to those that grow as multicellular colonies. Fungi, Filamentous,Molds,Filamentous Fungi,Filamentous Fungus,Fungus,Fungus, Filamentous,Mold
D006358 Hot Temperature Presence of warmth or heat or a temperature notably higher than an accustomed norm. Heat,Hot Temperatures,Temperature, Hot,Temperatures, Hot
D001419 Bacteria One of the three domains of life (the others being Eukarya and ARCHAEA), also called Eubacteria. They are unicellular prokaryotic microorganisms which generally possess rigid cell walls, multiply by cell division, and exhibit three principal forms: round or coccal, rodlike or bacillary, and spiral or spirochetal. Bacteria can be classified by their response to OXYGEN: aerobic, anaerobic, or facultatively anaerobic; by the mode by which they obtain their energy: chemotrophy (via chemical reaction) or PHOTOTROPHY (via light reaction); for chemotrophs by their source of chemical energy: CHEMOLITHOTROPHY (from inorganic compounds) or chemoorganotrophy (from organic compounds); and by their source for CARBON; NITROGEN; etc.; HETEROTROPHY (from organic sources) or AUTOTROPHY (from CARBON DIOXIDE). They can also be classified by whether or not they stain (based on the structure of their CELL WALLS) with CRYSTAL VIOLET dye: gram-negative or gram-positive. Eubacteria
D013242 Sterilization The destroying of all forms of life, especially microorganisms, by heat, chemical, or other means.
D013696 Temperature The property of objects that determines the direction of heat flow when they are placed in direct thermal contact. The temperature is the energy of microscopic motions (vibrational and translational) of the particles of atoms. Temperatures
D013997 Time Factors Elements of limited time intervals, contributing to particular results or situations. Time Series,Factor, Time,Time Factor

Related Publications

M G Harris, and J Rechberger, and T Grant, and B A Holden
February 1989, Optometry and vision science : official publication of the American Academy of Optometry,
M G Harris, and J Rechberger, and T Grant, and B A Holden
April 2001, The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc,
M G Harris, and J Rechberger, and T Grant, and B A Holden
May 1977, American journal of optometry and physiological optics,
M G Harris, and J Rechberger, and T Grant, and B A Holden
January 1991, Reviews of infectious diseases,
M G Harris, and J Rechberger, and T Grant, and B A Holden
September 1991, Optometry and vision science : official publication of the American Academy of Optometry,
M G Harris, and J Rechberger, and T Grant, and B A Holden
January 1981, Contact and intraocular lens medical journal,
M G Harris, and J Rechberger, and T Grant, and B A Holden
October 1993, Optometry and vision science : official publication of the American Academy of Optometry,
M G Harris, and J Rechberger, and T Grant, and B A Holden
January 1999, American journal of ophthalmology,
M G Harris, and J Rechberger, and T Grant, and B A Holden
December 1982, The Medical letter on drugs and therapeutics,
M G Harris, and J Rechberger, and T Grant, and B A Holden
August 1971, California medicine,
Copied contents to your clipboard!