Analysis of chromosome damage for biodosimetry using imaging flow cytometry. 2013

L A Beaton, and C Ferrarotto, and B C Kutzner, and J P McNamee, and P V Bellier, and R C Wilkins
Consumer and Clinical Radiation Protection Bureau, Health Canada, 775 Brookfield Road, Postal Locator 6303B, Ottawa, ON, Canada. Electronic address: Lindsay.Beaton@hc-sc.gc.ca.

The dicentric chromosome assay (DCA), which involves counting the frequency of dicentric chromosomes in mitotic lymphocytes and converting it to a dose-estimation for ionizing radiation exposure, is considered to be the gold standard for radiation biodosimetry. Furthermore, for emergency response, the DCA has been adapted for triage by simplifying the scoring method [1]. With the development of new technologies such as the imaging flow cytometer, it may now be possible to adapt this microscope-based method to an automated cytometry method. This technology allows the sensitivity of microscopy to be maintained while adding the increased throughput of flow cytometry. A new protocol is being developed to adapt the DCA to the imaging cytometer in order to further increase the rapid determination of a biological dose. Peripheral blood mononuclear cells (PBMC) were isolated from ex vivo irradiated whole blood samples using a density gradient separation method and cultured with PHA and Colcemid. After 48h incubation, the chromosomes were isolated, stained for DNA content with propidium iodide (PI) and labelled with a centromere marker. Stained chromosomes were then analyzed on the ImageStream(×) (EMD-Millipore, Billerica, MA). Preliminary results indicate that individual chromosomes can be identified and mono- and dicentric chromosomes can be differentiated by imaging cytometry. A dose response curve was generated using this technology. The details of the method and the dose response curve are presented and compared to traditional microscope scoring. Imaging cytometry is a new technology which enables the rapid, automated analysis of fluorescently labelled chromosomes. Adapting the dicentric assay to this technology has the potential for high throughput analysis for mass casualty events.

UI MeSH Term Description Entries
D008214 Lymphocytes White blood cells formed in the body's lymphoid tissue. The nucleus is round or ovoid with coarse, irregularly clumped chromatin while the cytoplasm is typically pale blue with azurophilic (if any) granules. Most lymphocytes can be classified as either T or B (with subpopulations of each), or NATURAL KILLER CELLS. Lymphoid Cells,Cell, Lymphoid,Cells, Lymphoid,Lymphocyte,Lymphoid Cell
D008938 Mitosis A type of CELL NUCLEUS division by means of which the two daughter nuclei normally receive identical complements of the number of CHROMOSOMES of the somatic cells of the species. M Phase, Mitotic,Mitotic M Phase,M Phases, Mitotic,Mitoses,Mitotic M Phases,Phase, Mitotic M,Phases, Mitotic M
D011829 Radiation Dosage The amount of radiation energy that is deposited in a unit mass of material, such as tissues of plants or animal. In RADIOTHERAPY, radiation dosage is expressed in gray units (Gy). In RADIOLOGIC HEALTH, the dosage is expressed by the product of absorbed dose (Gy) and quality factor (a function of linear energy transfer), and is called radiation dose equivalent in sievert units (Sv). Sievert Units,Dosage, Radiation,Gray Units,Gy Radiation,Sv Radiation Dose Equivalent,Dosages, Radiation,Radiation Dosages,Units, Gray,Units, Sievert
D011834 Radiation Monitoring The observation, either continuously or at intervals, of the levels of radiation in a given area, generally for the purpose of assuring that they have not exceeded prescribed amounts or, in case of radiation already present in the area, assuring that the levels have returned to those meeting acceptable safety standards. Monitoring, Radiation
D011874 Radiometry The measurement of radiation by photography, as in x-ray film and film badge, by Geiger-Mueller tube, and by SCINTILLATION COUNTING. Geiger-Mueller Counters,Nuclear Track Detection,Radiation Dosimetry,Dosimetry, Radiation,Geiger Counter,Geiger-Mueller Counter Tube,Geiger-Mueller Probe,Geiger-Mueller Tube,Radiation Counter,Counter Tube, Geiger-Mueller,Counter Tubes, Geiger-Mueller,Counter, Geiger,Counter, Radiation,Counters, Geiger,Counters, Geiger-Mueller,Counters, Radiation,Detection, Nuclear Track,Dosimetries, Radiation,Geiger Counters,Geiger Mueller Counter Tube,Geiger Mueller Counters,Geiger Mueller Probe,Geiger Mueller Tube,Geiger-Mueller Counter Tubes,Geiger-Mueller Probes,Geiger-Mueller Tubes,Probe, Geiger-Mueller,Probes, Geiger-Mueller,Radiation Counters,Radiation Dosimetries,Tube, Geiger-Mueller,Tube, Geiger-Mueller Counter,Tubes, Geiger-Mueller,Tubes, Geiger-Mueller Counter
D002869 Chromosome Aberrations Abnormal number or structure of chromosomes. Chromosome aberrations may result in CHROMOSOME DISORDERS. Autosome Abnormalities,Cytogenetic Aberrations,Abnormalities, Autosome,Abnormalities, Chromosomal,Abnormalities, Chromosome,Chromosomal Aberrations,Chromosome Abnormalities,Cytogenetic Abnormalities,Aberration, Chromosomal,Aberration, Chromosome,Aberration, Cytogenetic,Aberrations, Chromosomal,Aberrations, Chromosome,Aberrations, Cytogenetic,Abnormalities, Cytogenetic,Abnormality, Autosome,Abnormality, Chromosomal,Abnormality, Chromosome,Abnormality, Cytogenetic,Autosome Abnormality,Chromosomal Aberration,Chromosomal Abnormalities,Chromosomal Abnormality,Chromosome Aberration,Chromosome Abnormality,Cytogenetic Aberration,Cytogenetic Abnormality
D002877 Chromosomes, Human Very long DNA molecules and associated proteins, HISTONES, and non-histone chromosomal proteins (CHROMOSOMAL PROTEINS, NON-HISTONE). Normally 46 chromosomes, including two sex chromosomes are found in the nucleus of human cells. They carry the hereditary information of the individual. Chromosome, Human,Human Chromosome,Human Chromosomes
D004247 DNA A deoxyribonucleotide polymer that is the primary genetic material of all cells. Eukaryotic and prokaryotic organisms normally contain DNA in a double-stranded state, yet several important biological processes transiently involve single-stranded regions. DNA, which consists of a polysugar-phosphate backbone possessing projections of purines (adenine and guanine) and pyrimidines (thymine and cytosine), forms a double helix that is held together by hydrogen bonds between these purines and pyrimidines (adenine to thymine and guanine to cytosine). DNA, Double-Stranded,Deoxyribonucleic Acid,ds-DNA,DNA, Double Stranded,Double-Stranded DNA,ds DNA
D005434 Flow Cytometry Technique using an instrument system for making, processing, and displaying one or more measurements on individual cells obtained from a cell suspension. Cells are usually stained with one or more fluorescent dyes specific to cell components of interest, e.g., DNA, and fluorescence of each cell is measured as it rapidly transverses the excitation beam (laser or mercury arc lamp). Fluorescence provides a quantitative measure of various biochemical and biophysical properties of the cell, as well as a basis for cell sorting. Other measurable optical parameters include light absorption and light scattering, the latter being applicable to the measurement of cell size, shape, density, granularity, and stain uptake. Cytofluorometry, Flow,Cytometry, Flow,Flow Microfluorimetry,Fluorescence-Activated Cell Sorting,Microfluorometry, Flow,Cell Sorting, Fluorescence-Activated,Cell Sortings, Fluorescence-Activated,Cytofluorometries, Flow,Cytometries, Flow,Flow Cytofluorometries,Flow Cytofluorometry,Flow Cytometries,Flow Microfluorometries,Flow Microfluorometry,Fluorescence Activated Cell Sorting,Fluorescence-Activated Cell Sortings,Microfluorimetry, Flow,Microfluorometries, Flow,Sorting, Fluorescence-Activated Cell,Sortings, Fluorescence-Activated Cell
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man

Related Publications

L A Beaton, and C Ferrarotto, and B C Kutzner, and J P McNamee, and P V Bellier, and R C Wilkins
May 2014, Radiation and environmental biophysics,
L A Beaton, and C Ferrarotto, and B C Kutzner, and J P McNamee, and P V Bellier, and R C Wilkins
January 2016, Methods in molecular biology (Clifton, N.J.),
L A Beaton, and C Ferrarotto, and B C Kutzner, and J P McNamee, and P V Bellier, and R C Wilkins
January 2017, Genome integrity,
L A Beaton, and C Ferrarotto, and B C Kutzner, and J P McNamee, and P V Bellier, and R C Wilkins
July 2016, Cytometry. Part A : the journal of the International Society for Analytical Cytology,
L A Beaton, and C Ferrarotto, and B C Kutzner, and J P McNamee, and P V Bellier, and R C Wilkins
January 2011, Methods in molecular biology (Clifton, N.J.),
L A Beaton, and C Ferrarotto, and B C Kutzner, and J P McNamee, and P V Bellier, and R C Wilkins
January 2016, Health physics,
L A Beaton, and C Ferrarotto, and B C Kutzner, and J P McNamee, and P V Bellier, and R C Wilkins
January 2018, Methods in molecular biology (Clifton, N.J.),
L A Beaton, and C Ferrarotto, and B C Kutzner, and J P McNamee, and P V Bellier, and R C Wilkins
May 2011, Journal of clinical pathology,
L A Beaton, and C Ferrarotto, and B C Kutzner, and J P McNamee, and P V Bellier, and R C Wilkins
January 1991, Cytometry,
L A Beaton, and C Ferrarotto, and B C Kutzner, and J P McNamee, and P V Bellier, and R C Wilkins
January 2017, Methods (San Diego, Calif.),
Copied contents to your clipboard!