[The determination of suitable film-screen cassette combinations for orthodontic x-ray technics]. 1990

H Fischer-Brandies, and K Lindner
Poliklinik für Kieferorthopädie, Universität München.

16 film-screen cassette combinations (FSCC) were compared with regard to their detail sharpness and the radiation dose required. After standard adjustment to a uniform average optical density, the contrast and detail were analysed using a self-constructed microdensitometer. The following results were found; on average there is a 14.5% dose reduction using carbon fiber cassettes compared with aluminium cassettes. FSCC with especially low exposure time are: Cronex 2, fast detail, Du Pont (0.4 sec); Cronex 2, NPU, carbon fiber cassettes (0.5 sec); Curix RP1, NPU, carbon fiber cassettes (0.64 sec). The loss of quality associated with this and measured with the microdensitometer is insignificant for clinical orthodontic purposes. This study concludes that differences in contrast and detail do not justify the use of cassette combinations which require a high dose of radiation.

UI MeSH Term Description Entries
D009970 Orthodontics A dental specialty concerned with the prevention and correction of dental and oral anomalies (malocclusion).
D011829 Radiation Dosage The amount of radiation energy that is deposited in a unit mass of material, such as tissues of plants or animal. In RADIOTHERAPY, radiation dosage is expressed in gray units (Gy). In RADIOLOGIC HEALTH, the dosage is expressed by the product of absorbed dose (Gy) and quality factor (a function of linear energy transfer), and is called radiation dose equivalent in sievert units (Sv). Sievert Units,Dosage, Radiation,Gray Units,Gy Radiation,Sv Radiation Dose Equivalent,Dosages, Radiation,Radiation Dosages,Units, Gray,Units, Sievert
D011861 Radiography, Dental Radiographic techniques used in dentistry. Dental Radiography
D005069 Evaluation Studies as Topic Works about studies that determine the effectiveness or value of processes, personnel, and equipment, or the material on conducting such studies. Critique,Evaluation Indexes,Evaluation Methodology,Evaluation Report,Evaluation Research,Methodology, Evaluation,Pre-Post Tests,Qualitative Evaluation,Quantitative Evaluation,Theoretical Effectiveness,Use-Effectiveness,Critiques,Effectiveness, Theoretical,Evaluation Methodologies,Evaluation Reports,Evaluation, Qualitative,Evaluation, Quantitative,Evaluations, Qualitative,Evaluations, Quantitative,Indexes, Evaluation,Methodologies, Evaluation,Pre Post Tests,Pre-Post Test,Qualitative Evaluations,Quantitative Evaluations,Report, Evaluation,Reports, Evaluation,Research, Evaluation,Test, Pre-Post,Tests, Pre-Post,Use Effectiveness
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D014963 X-Ray Intensifying Screens Screens which absorb the energy in the x-ray beam that has penetrated the patient and convert this energy into a light pattern which has as nearly as possible the same information as the original x-ray beam. The more light a screen produces for a given input of x-radiation, the less x-ray exposure and thus shorter exposure time are needed to expose the film. In most film-screen systems, the film is sandwiched between two screens in a cassette so that the emulsion on each side is exposed to the light from its contiguous screen. Film-Screen Systems, X-Ray,Radiographic Intensifying Screens,Screen-Film Systems, X-Ray,X-Ray Film-Screen Systems,Screens, Radiographic Intensifying,Xray Intensifying Screens,Film Screen Systems, X Ray,Film-Screen System, X-Ray,Intensifying Screen, Radiographic,Intensifying Screen, X-Ray,Intensifying Screen, Xray,Intensifying Screens, Radiographic,Intensifying Screens, X-Ray,Intensifying Screens, Xray,Radiographic Intensifying Screen,Screen Film Systems, X Ray,Screen, Radiographic Intensifying,Screen, X-Ray Intensifying,Screen, Xray Intensifying,Screen-Film System, X-Ray,Screens, X-Ray Intensifying,Screens, Xray Intensifying,System, X-Ray Film-Screen,System, X-Ray Screen-Film,Systems, X-Ray Film-Screen,Systems, X-Ray Screen-Film,X Ray Film Screen Systems,X Ray Intensifying Screens,X-Ray Film-Screen System,X-Ray Intensifying Screen,X-Ray Screen-Film System,X-Ray Screen-Film Systems,Xray Intensifying Screen

Related Publications

H Fischer-Brandies, and K Lindner
May 1988, Physics in medicine and biology,
H Fischer-Brandies, and K Lindner
March 1970, Radiology,
H Fischer-Brandies, and K Lindner
January 1985, Radiologia diagnostica,
H Fischer-Brandies, and K Lindner
December 1985, Deutsche zahnarztliche Zeitschrift,
H Fischer-Brandies, and K Lindner
September 2001, The British journal of radiology,
H Fischer-Brandies, and K Lindner
October 2008, Medical & biological engineering & computing,
H Fischer-Brandies, and K Lindner
April 1958, Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin,
H Fischer-Brandies, and K Lindner
September 1990, The British journal of radiology,
H Fischer-Brandies, and K Lindner
January 1981, Medical physics,
H Fischer-Brandies, and K Lindner
January 1981, Rontgenpraxis; Zeitschrift fur radiologische Technik,
Copied contents to your clipboard!