The effect of a paraffin screen on the neutron dose at the maze door of a 15 MV linear accelerator. 2013

M Krmar, and D Nikolić, and A Kuzmanović, and Z Kuzmanović, and K Ganezer
Physics Department, Faculty of Science, University of Novi Sad, Novi Sad 21000, Serbia. krmar@df.uns.ac.rs

OBJECTIVE The purpose of this study was to explore the effects of a paraffin screen located at various positions in the maze on the neutron dose equivalent at the maze door. METHODS The neutron dose equivalent was measured at the maze door of a room containing a 15 MV linear accelerator for x-ray therapy. Measurements were performed for several positions of the paraffin screen covering only 27.5% of the cross-sectional area of the maze. The neutron dose equivalent was also measured at all screen positions. Two simple models of the neutron source were considered in which the first assumed that the source was the cross-sectional area at the inner entrance of the maze, radiating neutrons in an isotropic manner. In the second model the reduction in the neutron dose equivalent at the maze door due to the paraffin screen was considered to be a function of the mean values of the neutron fluence and energy at the screen. RESULTS The results of this study indicate that the equivalent dose at the maze door was reduced by a factor of 3 through the use of a paraffin screen that was placed inside the maze. It was also determined that the contributions to the dosage from areas that were not covered by the paraffin screen as viewed from the dosimeter, were 2.5 times higher than the contributions from the covered areas. This study also concluded that the contributions of the maze walls, ceiling, and floor to the total neutron dose equivalent were an order of magnitude lower than those from the surface at the far end of the maze. CONCLUSIONS This study demonstrated that a paraffin screen could be used to reduce the neutron dose equivalent at the maze door by a factor of 3. This paper also found that the reduction of the neutron dose equivalent was a linear function of the area covered by the maze screen and that the decrease in the dose at the maze door could be modeled as an exponential function of the product φ·E at the screen.

UI MeSH Term Description Entries
D009502 Neutrons Electrically neutral elementary particles found in all atomic nuclei except light hydrogen; the mass is equal to that of the proton and electron combined and they are unstable when isolated from the nucleus, undergoing beta decay. Slow, thermal, epithermal, and fast neutrons refer to the energy levels with which the neutrons are ejected from heavier nuclei during their decay. Neutron
D010232 Paraffin A mixture of solid hydrocarbons obtained from petroleum. It has a wide range of uses including as a stiffening agent in ointments, as a lubricant, and as a topical anti-inflammatory. It is also commonly used as an embedding material in histology. Parafilm
D010315 Particle Accelerators Devices which accelerate electrically charged atomic or subatomic particles, such as electrons, protons or ions, to high velocities so they have high kinetic energy. Betatrons,Linear Accelerators,Accelerator, Linear,Accelerator, Particle,Accelerators, Linear,Accelerators, Particle,Betatron,Linear Accelerator,Particle Accelerator
D011829 Radiation Dosage The amount of radiation energy that is deposited in a unit mass of material, such as tissues of plants or animal. In RADIOTHERAPY, radiation dosage is expressed in gray units (Gy). In RADIOLOGIC HEALTH, the dosage is expressed by the product of absorbed dose (Gy) and quality factor (a function of linear energy transfer), and is called radiation dose equivalent in sievert units (Sv). Sievert Units,Dosage, Radiation,Gray Units,Gy Radiation,Sv Radiation Dose Equivalent,Dosages, Radiation,Radiation Dosages,Units, Gray,Units, Sievert
D011835 Radiation Protection Methods and practices adopted to protect against RADIATION. Protection, Radiation
D014964 X-Ray Therapy Medical treatment involving the use of controlled amounts of X-Rays. Roentgenotherapy,Therapy, X Ray,Therapy, Xray,Xray Therapy,Roentgenotherapies,Therapies, X Ray,Therapies, X-Ray,Therapies, Xray,Therapy, X-Ray,X Ray Therapies,X Ray Therapy,X-Ray Therapies,Xray Therapies

Related Publications

M Krmar, and D Nikolić, and A Kuzmanović, and Z Kuzmanović, and K Ganezer
January 2007, Radiation protection dosimetry,
M Krmar, and D Nikolić, and A Kuzmanović, and Z Kuzmanović, and K Ganezer
May 2009, Medical physics,
M Krmar, and D Nikolić, and A Kuzmanović, and Z Kuzmanović, and K Ganezer
January 2007, Radiation protection dosimetry,
M Krmar, and D Nikolić, and A Kuzmanović, and Z Kuzmanović, and K Ganezer
February 2015, Radiation protection dosimetry,
M Krmar, and D Nikolić, and A Kuzmanović, and Z Kuzmanović, and K Ganezer
January 1985, Medical physics,
M Krmar, and D Nikolić, and A Kuzmanović, and Z Kuzmanović, and K Ganezer
July 2020, Radiation protection dosimetry,
M Krmar, and D Nikolić, and A Kuzmanović, and Z Kuzmanović, and K Ganezer
June 2023, Medical physics,
M Krmar, and D Nikolić, and A Kuzmanović, and Z Kuzmanović, and K Ganezer
March 1993, Journal of the National Medical Association,
M Krmar, and D Nikolić, and A Kuzmanović, and Z Kuzmanović, and K Ganezer
January 2005, Radiation protection dosimetry,
M Krmar, and D Nikolić, and A Kuzmanović, and Z Kuzmanović, and K Ganezer
January 1987, Medical physics,
Copied contents to your clipboard!