Estimation of effective imaging dose for kilovoltage intratreatment monitoring of the prostate position during cancer radiotherapy. 2013

J A Ng, and J Booth, and P Poulsen, and Z Kuncic, and P J Keall
Institute of Medical Physics, School of Physics, University of Sydney, NSW 2006, Australia.

Kilovoltage intratreatment monitoring (KIM) is a novel real-time localization modality where the tumor position is continuously measured during intensity modulated radiation therapy (IMRT) or intensity modulated arc therapy (IMAT) by a kilovoltage (kV) x-ray imager. Adding kV imaging during therapy adds radiation dose. The additional effective dose is quantified for prostate radiotherapy and compared to dose from other localization modalities. The software PCXMC 2.0 was used to calculate the effective dose delivered to a phantom as a function of imager angle and field size for a Varian On-Board Imager. The average angular effective dose was calculated for a field size of 6 cm × 6 cm. The average angular effective dose was used in calculations for different treatment scenarios. Treatment scenarios considered were treatment type and fractionation. For all treatment scenarios, (i.e. conventionally fractionated and stereotactic body radiotherapy (SBRT), IMRT and IMAT), the total KIM dose at 1 Hz ranged from 2-10 mSv. This imaging dose is less than the Navotek radioactive implant dose (64 mSv) and a standard SBRT cone beam computed tomography pretreatment scan dose (22 mSv) over an entire treatment regime. KIM delivers an acceptably low effective dose for daily use as a real-time image-guidance method for prostate radiotherapy.

UI MeSH Term Description Entries
D008297 Male Males
D011471 Prostatic Neoplasms Tumors or cancer of the PROSTATE. Cancer of Prostate,Prostate Cancer,Cancer of the Prostate,Neoplasms, Prostate,Neoplasms, Prostatic,Prostate Neoplasms,Prostatic Cancer,Cancer, Prostate,Cancer, Prostatic,Cancers, Prostate,Cancers, Prostatic,Neoplasm, Prostate,Neoplasm, Prostatic,Prostate Cancers,Prostate Neoplasm,Prostatic Cancers,Prostatic Neoplasm
D011829 Radiation Dosage The amount of radiation energy that is deposited in a unit mass of material, such as tissues of plants or animal. In RADIOTHERAPY, radiation dosage is expressed in gray units (Gy). In RADIOLOGIC HEALTH, the dosage is expressed by the product of absorbed dose (Gy) and quality factor (a function of linear energy transfer), and is called radiation dose equivalent in sievert units (Sv). Sievert Units,Dosage, Radiation,Gray Units,Gy Radiation,Sv Radiation Dose Equivalent,Dosages, Radiation,Radiation Dosages,Units, Gray,Units, Sievert
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000328 Adult A person having attained full growth or maturity. Adults are of 19 through 44 years of age. For a person between 19 and 24 years of age, YOUNG ADULT is available. Adults
D014057 Tomography, X-Ray Computed Tomography using x-ray transmission and a computer algorithm to reconstruct the image. CAT Scan, X-Ray,CT Scan, X-Ray,Cine-CT,Computerized Tomography, X-Ray,Electron Beam Computed Tomography,Tomodensitometry,Tomography, Transmission Computed,X-Ray Tomography, Computed,CAT Scan, X Ray,CT X Ray,Computed Tomography, X-Ray,Computed X Ray Tomography,Computerized Tomography, X Ray,Electron Beam Tomography,Tomography, X Ray Computed,Tomography, X-Ray Computer Assisted,Tomography, X-Ray Computerized,Tomography, X-Ray Computerized Axial,Tomography, Xray Computed,X Ray Computerized Tomography,X Ray Tomography, Computed,X-Ray Computer Assisted Tomography,X-Ray Computerized Axial Tomography,Beam Tomography, Electron,CAT Scans, X-Ray,CT Scan, X Ray,CT Scans, X-Ray,CT X Rays,Cine CT,Computed Tomography, Transmission,Computed Tomography, X Ray,Computed Tomography, Xray,Computed X-Ray Tomography,Scan, X-Ray CAT,Scan, X-Ray CT,Scans, X-Ray CAT,Scans, X-Ray CT,Tomographies, Computed X-Ray,Tomography, Computed X-Ray,Tomography, Electron Beam,Tomography, X Ray Computer Assisted,Tomography, X Ray Computerized,Tomography, X Ray Computerized Axial,Transmission Computed Tomography,X Ray Computer Assisted Tomography,X Ray Computerized Axial Tomography,X Ray, CT,X Rays, CT,X-Ray CAT Scan,X-Ray CAT Scans,X-Ray CT Scan,X-Ray CT Scans,X-Ray Computed Tomography,X-Ray Computerized Tomography,Xray Computed Tomography
D056888 Patient Positioning Moving a patient into a specific position or POSTURE to facilitate examination, surgery, or for therapeutic purposes. Patient Positionings,Positioning, Patient,Positionings, Patient
D061089 Radiotherapy, Image-Guided The use of pre-treatment imaging modalities to position the patient, delineate the target, and align the beam of radiation to achieve optimal accuracy and reduce radiation damage to surrounding non-target tissues. Image-Guided Radiation Therapy,Radiotherapy Target Organ Alignment,Target Organ Alignment, Radiotherapy,Image Guided Radiation Therapy,Image-Guided Radiation Therapies,Image-Guided Radiotherapies,Image-Guided Radiotherapy,Radiation Therapies, Image-Guided,Radiation Therapy, Image-Guided,Radiotherapies, Image-Guided,Radiotherapy, Image Guided,Therapies, Image-Guided Radiation,Therapy, Image-Guided Radiation
D019047 Phantoms, Imaging Devices or objects in various imaging techniques used to visualize or enhance visualization by simulating conditions encountered in the procedure. Phantoms are used very often in procedures employing or measuring x-irradiation or radioactive material to evaluate performance. Phantoms often have properties similar to human tissue. Water demonstrates absorbing properties similar to normal tissue, hence water-filled phantoms are used to map radiation levels. Phantoms are used also as teaching aids to simulate real conditions with x-ray or ultrasonic machines. (From Iturralde, Dictionary and Handbook of Nuclear Medicine and Clinical Imaging, 1990) Phantoms, Radiographic,Phantoms, Radiologic,Radiographic Phantoms,Radiologic Phantoms,Phantom, Radiographic,Phantom, Radiologic,Radiographic Phantom,Radiologic Phantom,Imaging Phantom,Imaging Phantoms,Phantom, Imaging
D019583 Dose Fractionation, Radiation Administration of the total dose of radiation (RADIATION DOSAGE) in parts, at timed intervals. Radiotherapy Dose Fractionation,Dose Fractionation, Radiotherapy,Radiation Dose Fractionation,Dose Fractionations, Radiotherapy,Fractionation, Radiation Dose,Fractionation, Radiotherapy Dose,Fractionations, Radiotherapy Dose,Radiotherapy Dose Fractionations

Related Publications

J A Ng, and J Booth, and P Poulsen, and Z Kuncic, and P J Keall
April 2020, Cancer radiotherapie : journal de la Societe francaise de radiotherapie oncologique,
J A Ng, and J Booth, and P Poulsen, and Z Kuncic, and P J Keall
September 2010, Medical physics,
J A Ng, and J Booth, and P Poulsen, and Z Kuncic, and P J Keall
January 2016, Journal of cancer research and therapeutics,
J A Ng, and J Booth, and P Poulsen, and Z Kuncic, and P J Keall
March 2008, Physics in medicine and biology,
J A Ng, and J Booth, and P Poulsen, and Z Kuncic, and P J Keall
April 2017, Medical physics,
J A Ng, and J Booth, and P Poulsen, and Z Kuncic, and P J Keall
January 2011, International journal of radiation oncology, biology, physics,
J A Ng, and J Booth, and P Poulsen, and Z Kuncic, and P J Keall
August 2002, The British journal of radiology,
J A Ng, and J Booth, and P Poulsen, and Z Kuncic, and P J Keall
July 2014, IEEE transactions on medical imaging,
J A Ng, and J Booth, and P Poulsen, and Z Kuncic, and P J Keall
April 2012, International journal of radiation oncology, biology, physics,
Copied contents to your clipboard!