Marginal fit of implant-supported all-ceramic zirconia frameworks. 2013

Hanaa Hassan Zaghloul, and Jihan Farouk Younis
Conservative Dentistry Department, Faculty of Oral and Dental Medicine, Misr International University, Cairo, Egypt. hh_zaghloul@hotmail.com

This study evaluated the effect of fabrication techniques and cyclic loading on the vertical marginal fit of implant-supported fixed partial denture (FPD) frameworks. Thirty implant-supported 3-unit FPD frameworks were fabricated on a model system, divided into 3 equal groups (n = 10). The first group (control) was constructed from base metal alloy; the other 2 test groups were constructed from all-ceramic zirconia using a computer-aided design/computer-aided manufacturing (CAD/CAM) Cerec 3 system and a copy milling (Zirkonzahn) system. A cyclic load of 200 N was applied to each framework for up to 50,000 cycles. Linear measurements were made in micrometers of the vertical gap between the framework and the implant-supported abutment at 16 predetermined points before and after cyclic loading. The frameworks were viewed using scanning electron microscopy to inspect any fractographic features. One-way analysis of variance was performed to compare the marginal discrepancy values of the control and the 2 test groups and for each group; a t test was applied to determine whether significant changes in the fit were observed after cyclic loading (α = 0.05). The CAD/CAM group showed significantly higher marginal gap mean values (80.58 μm) than the Zirkonzahn and control groups (50.33 μm and 42.27 μm, respectively) with no significant difference. After cyclic loading, the CAD/CAM group recorded the highest marginal gap mean value (91.50 ± 4.260 μm) followed by control group (72.00 ± 2.795 μm); the Zirkonzahn group recorded the lowest marginal gap (65.37 ± 6.138 μm). Cyclic loading significantly increased the marginal gap mean values in the control group only. A marginal chip was observed in one of the CAD/CAM ceramic frameworks. Within the limitations of this study, the fabrication technique influenced the marginal fit of the implant-supported 3-unit FPD frameworks. Cyclic loading failed to change the fit of all-ceramic zirconia frameworks, whereas significant changes were found in the metal frameworks.

UI MeSH Term Description Entries
D008855 Microscopy, Electron, Scanning Microscopy in which the object is examined directly by an electron beam scanning the specimen point-by-point. The image is constructed by detecting the products of specimen interactions that are projected above the plane of the sample, such as backscattered electrons. Although SCANNING TRANSMISSION ELECTRON MICROSCOPY also scans the specimen point by point with the electron beam, the image is constructed by detecting the electrons, or their interaction products that are transmitted through the sample plane, so that is a form of TRANSMISSION ELECTRON MICROSCOPY. Scanning Electron Microscopy,Electron Scanning Microscopy,Electron Microscopies, Scanning,Electron Microscopy, Scanning,Electron Scanning Microscopies,Microscopies, Electron Scanning,Microscopies, Scanning Electron,Microscopy, Electron Scanning,Microscopy, Scanning Electron,Scanning Electron Microscopies,Scanning Microscopies, Electron,Scanning Microscopy, Electron
D003722 Dental Alloys A mixture of metallic elements or compounds with other metallic or metalloid elements in varying proportions for use in restorative or prosthetic dentistry. Alloy, Dental,Alloys, Dental,Dental Alloy
D003776 Dental Porcelain A type of porcelain used in dental restorations, either jacket crowns or inlays, artificial teeth, or metal-ceramic crowns. It is essentially a mixture of particles of feldspar and quartz, the feldspar melting first and providing a glass matrix for the quartz. Dental porcelain is produced by mixing ceramic powder (a mixture of quartz, kaolin, pigments, opacifiers, a suitable flux, and other substances) with distilled water. (From Jablonski's Dictionary of Dentistry, 1992) Porcelain,Porcelain, Dental,Dental Porcelains,Porcelains,Porcelains, Dental
D003799 Dental Stress Analysis The description and measurement of the various factors that produce physical stress upon dental restorations, prostheses, or appliances, materials associated with them, or the natural oral structures. Analyses, Dental Stress,Analysis, Dental Stress,Stress Analyses, Dental,Stress Analysis, Dental,Dental Stress Analyses
D003830 Denture, Partial, Fixed A partial denture attached to prepared natural teeth, roots, or implants by cementation. Fixed Bridge,Fixed Partial Denture,Pontic,Bridge, Fixed,Bridges, Fixed,Denture, Fixed Partial,Dentures, Fixed Partial,Fixed Bridges,Fixed Partial Dentures,Partial Denture, Fixed,Partial Dentures, Fixed,Pontics
D006801 Humans Members of the species Homo sapiens. Homo sapiens,Man (Taxonomy),Human,Man, Modern,Modern Man
D000704 Analysis of Variance A statistical technique that isolates and assesses the contributions of categorical independent variables to variation in the mean of a continuous dependent variable. ANOVA,Analysis, Variance,Variance Analysis,Analyses, Variance,Variance Analyses
D015040 Zirconium A rather rare metallic element with atomic number 40, atomic weight 91.224, and symbol Zr.
D017076 Computer-Aided Design The use of computers for designing and/or manufacturing of anything, including drugs, surgical procedures, orthotics, and prosthetics. CAD-CAM,Computer-Aided Manufacturing,Computer-Assisted Design,Computer-Assisted Manufacturing,Computer Aided Design,Computer Aided Manufacturing,Computer Assisted Design,Computer Assisted Manufacturing,Computer-Aided Designs,Computer-Assisted Designs,Design, Computer-Aided,Design, Computer-Assisted,Designs, Computer-Aided,Designs, Computer-Assisted,Manufacturing, Computer-Aided,Manufacturing, Computer-Assisted
D017267 Dental Prosthesis Design The plan and delineation of dental prostheses in general or a specific dental prosthesis. It does not include DENTURE DESIGN. The framework usually consists of metal. Dental Prosthesis Designs,Design, Dental Prosthesis,Designs, Dental Prosthesis,Prosthesis Design, Dental,Prosthesis Designs, Dental

Related Publications

Hanaa Hassan Zaghloul, and Jihan Farouk Younis
July 2018, The Journal of prosthetic dentistry,
Hanaa Hassan Zaghloul, and Jihan Farouk Younis
January 2010, The International journal of prosthodontics,
Hanaa Hassan Zaghloul, and Jihan Farouk Younis
October 2006, Clinical oral implants research,
Hanaa Hassan Zaghloul, and Jihan Farouk Younis
June 1982, Die Quintessenz der Zahntechnik,
Hanaa Hassan Zaghloul, and Jihan Farouk Younis
January 2020, Journal of long-term effects of medical implants,
Hanaa Hassan Zaghloul, and Jihan Farouk Younis
March 2017, The Journal of prosthetic dentistry,
Hanaa Hassan Zaghloul, and Jihan Farouk Younis
January 2011, Journal of prosthodontic research,
Copied contents to your clipboard!